Explosion Protection
Pepperl-fuchs  Explosion Protection KFD2-GUT-EX1.D Part no:231225 With Good Price In Stock

Pepperl-fuchs Explosion Protection KFD2-GUT-EX1.D Part no:231225 With Good Price In Stock

Model: KFD2-GUT-EX1.D

$1.00

Supplier: Pepperl+Fuchs

Categories: Explosion Protection

After sales service. If you have any questions, click here.

Product Description

Pepperl-fuchs  Explosion Protection KFD2-GUT-EX1.D Part no:231225 With Good Price In Stock


Pepperl + Fuchs KFD2-GUT-Ex1.D temperature converter is used for intrinsic safety applications.

Brand: Pepperl + Fuchs

Place of origin: Singapore / Germany


Pepperl+Fuchs is a leading supplier of automation equipment for a wide range of industries and has been associated with safety in hazardous areas for decades. Our deep expertise enables us to offer a complete range of automation solutions for the process automation industry.

The product portfolio includes intrinsic safety isolators, Zener barriers, signal conditioners, fieldbus technology, Remote I/O, HART interfaces, level measurement, purge & pressurization systems, Human Machine Interfaces (HMI) for hazardous environments, custom cabinets, and junction boxes.

We provide process industry companies all over the world with proven components and tailor-made solutions for a diverse range of applications. The branches that we cover include the oil and gas industry, petrochemical, chemical industry, pharmaceutical industry, as well as wastewater treatment plants, and power technology.


1. General Introduction

The device converts the signal of a resistance thermometer, thermocouple, potentiometer, or voltage source to a

proportional output current. It also provides a relay trip value. The removable terminal block K-CJC-** is available as an

accessory for internal cold junction compensation of thermocouples. A fault is signalized by LEDs acc. to NAMUR NE44 and a

separate collective error message output. The device is easily configured by the use of the PACTware configuration software.

For additional information, refer to the manual.

 

 2. General Specification for KFD2-GUT-Ex1.D

Model

KFD2-GUT-Ex1.D

General   specifications

Signal type

Analog input

Functional   safety related parameters

Safety Integrity   Level (SIL

SIL 2

Supply

Connection

terminals 23+,   24- or power feed module/Power Rail

Rated voltage Ur

20 ... 30 V DC

Rated current Ir

approx. 100 mA

Power   dissipation/power consumption

≤ 2 W / 2.2 W

Interface


Programming   interface

programming   socket

Input

Connection side

field side

Connection

terminals 1, 2,   3, 4, 6

RTD

Pt100, Pt500,   Pt1000, Ni100, Ni1000

Measuring   current

approx. 400 A   with resistance measuring sensor

Types of   measuring

2-, 3-, 4-wire   connection

Lead resistance

≤ 50 Ω per line

Measurement loop   monitoring

sensor breakage,   sensor short-circuit

Thermocouples

type B, E, J, K,   L, N, R, S, T (IEC 584-1: 1995)

Cold junction   compensation

external and   internal

Measurement loop   monitoring

sensor breakage

Potentiometer

0.8 ... 20 k

Voltage

0 ... 10 V , 2   ... 10 V , 0 ... 1 V , -100 ... 100 mV

Input resistance

≥250 k(0 ... 10 V)

≥1 M(0 ... 1   V, -100 ... 100 mV)

Output

Connection side

control side

Connection

output I: terminals 10, 11, 12

output II: terminals 16, 17, 18

output III:   terminals 8+, 7-

Output I, II

relay

Contact loading

250 V AC / 2 A /   cos ≥0.7 ; 40 DC / 2

Mechanical life

5 x 107   switching cycles

Energized/De-energized   delay

approx. 20 ms /   approx. 20 ms

Open loop   voltage

≤24 V DC

Fault signal

downscale I   ≤3.6 mA, upscale I ≥21 mA (acc. NAMUR NE43)

Collective error   message

Power Rail

Transfer   characteristics


Deviation


Temperature   effect

Input: 0.005 %/K   (50 ppm) of span ; current output: 0.005 %/K (50 ppm) of span

RTD

≤0.2 % of span

Thermocouples

max. 10μV

deviation of   CJC: ±0.8 K

Voltage

0.1 % of span

Potentiometer

0.1 % of span when < 5 k

0.5 % of span   when > 5 k

Galvanic   isolation

Input/Other   circuits

reinforced   insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Output I, II   against eachother

reinforced   insulation according to IEC/EN 61010-1, rated insulation voltage 300

Output I,   II/other circuits

reinforced   insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Output III/power   supply and collective

error

reinforced   insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Interface/power   supply

reinforced   insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Indicators/settings

Display elements

LEDs display

Control elements

Control panel

Configuration

via operating buttons

via PACTware

Labeling

space for labeling at the front

Directive   conformity


Electromagnetic   compatibility


Directive   2014/30/EU

EN 61326-1:2013   (industrial locations)

Conformity

Electromagnetic   compatibility

NE 21:2011

Degree of   protection

IEC 60529:2001

Protection   against electrical shock

UL 61010-1:2004

Ambient   conditions

Ambient   temperature

-20 ... 60 °C   (-4 ... 140 °F)

 

3. Connection

 02

4. Assembly

 01

Pepperl-fuchs  Explosion Protection KFD2-GUT-EX1.D Part no:231225



KFD0-CC-EX1
KFD0-TR-EX1
KFD0-TT-EX1
KFD2-PT2-EX1
KFD2-PT2-EX1-1
KFD2-PT2-EX1-4
KFD2-PT2-EX1-5
KFD2-VR-EX1.18
KFD2-VR-EX1.19
KFD0-CS-EX1.50P
KFD0-CS-EX2.50P
KFD0-CS-EX1.51P
KFD0-CS-EX2.51P
KFD0-CS-EX1.53
KFD0-CS-EX2.53
KFD2-GU-EX1 PAR.
KFD2-PT2-EX1-Y98312
KFD2-CD-EX1.32
KFD2-CD-EX1.32-10
KFD2-CD-EX1.32-1
KFD2-CD-EX1.32-12
KFD2-CD-EX1.32-13
KFD2-CD-EX1.32-15
KFD2-CD-EX1.32-2
KFD2-CD-EX1.32-21
KFD2-CD-EX1.32-3
KFD2-CD-EX1.32-5
KFD2-CD-EX1.32-6
KFD2-CD-EX1.32-8
KFD2-CD-EX1.32-9


Windy Wang
HONGKONG XIEYUAN TECH CO., LIMITED  
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com
Website:  http://www.hkxytech.com/   | GMT/UTC +8

 

Related Products