Model: KFD2-SR2-EX1.W.LB

$1.00

Supplier: Pepperl+Fuchs

Categories: Explosion Protection

After sales service. If you have any questions, click here.

Product Description

Pepperl-Fuchs KFD2-SR2-Ex1.W.LB Switch Amplifier Part no: 203351 With Special Discount In Ready Stock

Pepperl+Fuchs is a leading supplier of automation equipment for a wide range of industries and has been associated with safety in hazardous areas for decades. Our deep expertise enables us to offer a complete range of automation solutions for the process automation industry.


This isolated barrier is used for intrinsic safety applications.

The device transfers digital signals from NAMUR sensors or dry contacts from the hazardous area to the non-hazardous area.

The proximity sensor or the mechanical contact controls the control side load for a relay contact output. The device output changes the state when

the input signal changes the state.

Via switches the mode of operation can be reversed and the line fault detection can be switched off.

During a fault condition, the relay reverts to its de-energized state and the LEDs indicate the fault according to NAMUR NE 44.

If the device is operated via Power Rail, additionally a collective error message is available.


  • 1-channel isolated barrier

  • 24 V DC supply (Power Rail)

  • Dry contact or NAMUR inputs

  • Usable as signal splitter (1 input and 2 outputs)

  • Relay contact output

  • Fault relay contact output

  • Line fault detection (LFD)

  • Reversible mode of operation

  • Up to SIL 2 (SC 3) acc. to IEC/EN 61508


General specifications
Signal typeDigital Input
Functional safety related parameters
Safety Integrity Level (SIL)SIL 2
Systematic capability (SC)SC 3
Supply
ConnectionPower Rail or terminals 14+, 15-
Rated voltage19 ... 30 V DC
Ripple≤ 10 %
Rated current≤ 45 mA
Power dissipation≤ 0.9 W
Power consumption≤ 0.9 W
Input
Connection sidefield side
Connectionterminals 1+, 2+, 3-
Rated valuesacc. to EN 60947-5-6 (NAMUR)
Open circuit voltage/short-circuit currentapprox. 8 V DC / approx. 8 mA
Switching point/switching hysteresis1.2 ... 2.1 mA / approx. 0.2 mA
Line fault detectionbreakage I ≤ 0.1 mA , short-circuit I > 6 mA
Pulse/Pause ratiomin. 20 ms / min. 20 ms
Output
Connection sidecontrol side
Connectionoutput I: terminals 7, 8, 9 ; output II: terminals 10, 11, 12
Output Isignal ; relay
Output IIsignal or fault message ; relay
Contact loading250 V AC/2 A/cos φ > 0.75; 126.5 V AC/4 A/cos φ > 0.75; 40 V DC/2 A resistive load
Minimum switch current2 mA / 24 V DC
Energized/De-energized delayapprox. 20 ms / approx. 20 ms
Mechanical life107 switching cycles
Collective error messagePower Rail
Transfer characteristics
Switching frequency≤ 10 Hz
Galvanic isolation
Input/Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Input/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output/Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Indicators/settings
Display elementsLEDs
Control elementsDIP switch
Configurationvia DIP switches
Labelingspace for labeling at the front

KFD2-SR2-Ex1.W.LB


Pepperl-Fuchs KFD2-SR2-Ex1.W.LB

KFD2-SH-EX1.T.OP
KFD0-RO-EX2 Relay Module
KFD2-SH-EX1
KHA6-SH-EX1
KFD2-VM-EX1.35.L
KFA5-SR2-EX2.W
KFA5-SR2-EX1.W
KFA5-SR2-EX1.W.LB
KFA6-SR2-EX2.W
KFA6-SR2-EX1.W
KFA6-SR2-EX1.W.LB
KFA6-SR2-EX2.W.IR
KFA5-SR2-EX2.W.IR
F-KDR-EX2 14-0290A
F-KD-EX2 14-0291B
KFA4-SR2-EX1.W
KFA4-SR2-EX1.W.LB
KFA4-SR2-EX2.W
KFA6-ER-EX1.W.LB
KFA5-ER-EX1.W.LB
KFA5-SR2-EX1.W-IFM
KFA6-SR2-EX1.W-IFM
KFA5-SR2-EX2.W-IFM
KFA6-SR2-EX2.W-IFM
KFD2-SR2-EX1.W-IFM
KFD2-SR2-EX2.W-IFM
KFD2-SR2-EX2.W.SM
KFD0-SD2-EX1.10100
KFD0-SD2-EX1.1065
KFD0-SD2-EX1.1180
KFD2-ST2-EX1.LB
KFD2-ST2-EX1.LB-IFM
KFD2-ST2-EX2
KFD2-ST2-EX2-IFM
KFD2-SOT2-EX1.LB
KFD2-SOT2-EX1.LB-IFM
KFD2-SOT2-EX1.LB.IO
KFD2-SOT2-EX2
KFD2-SOT2-EX2-IFM
KFD2-SOT2-EX2.IO
KFD2-SOT2-EX2.IO-Y181008
KFD2-SR2-EX2.2S
KFD2-SL2-EX1
KFD2-SL2-EX1.B
KFD2-SL2-EX2
KFD2-SL2-EX2.B
KFD2-SRA-EX4
KFD2-SOT2-EX1.N
KFA4-SR2-EX2.W-IFM
KFD2-SL2-EX1.LK
KFD2-SL2-EX1.LK.1045
KFD2-SR2-EX1.W
KFD2-SR2-EX1.W.LB
KFD2-SR2-EX2.W
KFD0-RSH-1
KFD2-SL2-EX1.LK.1270
KCD2-SR-EX2-PAR
KCD2-ST-EX1.LB
KCD2-SOT-EX1.LB
KCD2-SON-EX1
KCD2-ST-EX2
KCD2-SOT-EX2
KCD2-ST-1.LB
KCD2-SOT-1.LB
KCD2-ST-2
KCD2-SOT-2
KCD2-SR-EX2-Y1
KFD0-RSH-1-Y2
KFD2-RCI-EX1
KCD2-SR-EX1.LB
KCD2-SR-EX2
KFD2-ER-EX1.W.LB
KFD2-SH-EX1.T
KFD2-RCI-EX1 METSO
KFD0-RSH-1.4S.PS2
KCD2-SON-EX2
KFD2-UFC-EX1.D
KFU8-UFC-EX1.D
KFD2-UFT-EX2.D
KFU8-UFT-EX2.D
KFD2-DWB-EX1.D
KFA6-DWB-EX1.D
KFA5-DWB-EX1.D
KFA5-DU-EX1.D
KFA6-DU-EX1.D
KFD2-DU-EX1.D
KCD0-SD-EX1.1245
KFA5-SOT2-EX2
KFA6-SOT2-EX2
KFD2-SOT2-EX1.R1
KCD0-SD-Ex1.1245.SP
KCD2-SON-EX1.SP
KCD2-SON-EX2.SP
KCD2-SOT-1.LB.SP
KCD2-SOT-2.SP
KCD2-SOT-EX1.LB.SP
KCD2-SOT-EX2.SP
KCD2-SR-EX1.LB.SP

The product portfolio includes intrinsic safety isolators, Zener barriers, signal conditioners, fieldbus technology, Remote I/O, HART interfaces, level measurement, purge & pressurization systems, Human Machine Interfaces (HMI) for hazardous environments, custom cabinets, and junction boxes.

We provide process industry companies all over the world with proven components and tailor-made solutions for a diverse range of applications. The branches that we cover include the oil and gas industry, petrochemical, chemical industry, pharmaceutical industry, as well as wastewater treatment plants, and power technology.


Windy Wang

HONGKONG XIEYUAN TECH CO., LIMITED  
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com
Website:  http://www.hkxytech.com/   | GMT/UTC +8
 

Related Products