Safety
PHOENIX FO converters PSI-MOS-PROFIB/FO 660 T 2708287

PHOENIX FO converters PSI-MOS-PROFIB/FO 660 T 2708287

Model: 2708287

$1.00

Supplier: Phoenix Contact

Categories: Safety

After sales service. If you have any questions, click here.

Product Description

PHOENIX FO converters PSI-MOS-PROFIB/FO 660 T 2708287
 
phoenix-contact 270828

Phoenix Contact's roots are in Germany. Our headquarters are in Blomberg. Originally founded in Essen in 1923, we have grown over the years. This is true not only with regard to production and technology, but also in terms of the variety of products and business units. Learn more about our business areas and discover more about the members of the Executive Board on our website.

Key Commercial Data

Orderkey2708287
Packing unit1 pc
Catalog pagePage 325 (C-6-2017)
GTIN4017918973988
Weight per Piece (excluding packing)191.380 g
Custom tariff number85176200
Country of originDE (Germany)


Note

Utilization restriction1

Dimensions

Dimensional drawing
Width35 mm
Height99 mm
Depth106 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)30 % ... 95 % (non-condensing)
Altitude5000 m (For restrictions see manufacturer's declaration)
Degree of protectionIP20
Noise immunityEN 61000-6-2:2005

General

Bit delay≤ 1 bit
Bit distortion, input± 35 % (permitted)
Bit distortion, output< 6.25 %
Electrical isolationVCC // RS-485
Test voltage data interface/power supply1.5 kVrms(50 Hz, 1 min.)
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Noise emissionEN 55011
Net weight191.38 g
Housing materialPA 6.6-FR
Colorgreen
MTBF201 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))

42 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day))
MTTF213 Years (SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week, 8 hours a day))

150 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day))

86 Years (SN 29500 standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day))
ConformanceCE-compliant
ATEX II 3 G Ex nA nC IIC T4 Gc X (Please follow the special installation instructions in the documentation!)

 II (2) G [Ex op is Gb] IIC (PTB 06 ATEX 2042 U) (Please follow the special installation instructions in the documentation!)

 II (2) D [Ex op is Db] IIIC (PTB 06 ATEX 2042 U) (Please follow the special installation instructions in the documentation!)
UL, USA/CanadaClass I, Zone 2, AEx nc IIC T5

Class I, zone 2, Ex nC nL IIC T5 X

Class I, Div. 2, Groups A, B, C, D

Power supply

Nominal supply voltage24 V DC (With UL approval)
Supply voltage range18 V DC ... 30 V DC
Max. current consumption130 mA
Typical current consumption100 mA (24 V DC)
Connection methodCOMBICON plug-in screw terminal block

Serial interface

Interface 1PROFIBUS acc. to IEC 61158, RS-485 2-wire, half duplex, automatic control
InterfacePROFIBUS
Operating modeSemi-duplex
Connection methodD-SUB-9 female connector
File format/codingUART (11 Bit, NRZ)
Data direction switchingAutomatic control
Transmission mediumCopper
Transmission length≤ 1200 m (depending on the data rate, with shielded, twisted pair data cable)
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Serial transmission speed≤ 12 Mbps

Optical interface FO

Transmit capacity, minimum-3 dBm (980/1000 µm)

-15.4 dBm (200/230 µm)
Minimum receiver sensitivity-30 dBm
Overrange receiver-3 dBm (980/1000 µm)
Wavelength660 nm
Transmission length incl. 3 dB system reserve70 m (With F-P 980/1000 230 dB/km with quick mounting connector)

400 m (With F-K 200/230 10 dB/km with quick mounting connector)
Transmission mediumPolymer fiber

PCF fiber
Transmission protocolProtocol-transparent to the RS-485 interface
Connection methodF-SMA

Digital outputs

Output nameRelay output
Output descriptionAlarm output
Number of outputs1
Maximum switching voltage60 V DC

42 V AC
Limiting continuous current0.46 A

Standards and Regulations

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Type of testVibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6
Test result5g, 10...150 Hz, 2.5 h, in XYZ direction
Type of testShock in acc. with EN 60068-2-27/IEC 60068-2-27
Test result15g, 11 ms period, half-sine shock pulse
Noise emissionEN 55011
Noise immunityEN 61000-6-2:2005
Free from substances that could impair the application of coatingaccording to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard
Connection in acc. with standardCUL
Standards/regulationsEN 61000-4-2
Contact discharge± 6 kV
Standards/regulationsEN 61000-4-3

EN 61000-4-4
CommentsCriterion B
Standards/regulationsEN 61000-4-5
Signal± 1 kV
Standards/regulationsEN 55011

EN 61000-4-6
Shock15g in all directions in acc. with IEC 60068-2-27
Vibration (operation)in acc. with IEC 60068-2-6: 5g, 150 Hz
ConformanceCE-compliant
ATEX II 3 G Ex nA nC IIC T4 Gc X

 II (2) G [Ex op is Gb] IIC (PTB 06 ATEX 2042 U)

 II (2) D [Ex op is Db] IIIC (PTB 06 ATEX 2042 U)
UL, USA/CanadaClass I, Zone 2, AEx nc IIC T5

Class I, zone 2, Ex nC nL IIC T5 X

Class I, Div. 2, Groups A, B, C, D
DNV GL-TemperatureB
DNV GL-HumidityA
DNV GL-VibrationA
DNV GL-EMCB
DNV GL-EnclosureRequired protection according to the Rules shall be provided upon installation on board
Noxious gas testISA-S71.04-1985 G3 Harsh Group A

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50

For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”


                                                                                                                                                                                                                                                                                                              Contact insert, Range of articles: VARIOCON, Contact insert, housing material: PA 6.6, number of positions: 8, nom. voltage: 160, rated current: 10 A, Connection method: Screw connection, Type of contact: Pin. Connectors may only be connected/disconnected when under no load..



Windy Wang

HONGKONG XIEYUAN TECH CO., LIMITED  
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com
Website:  http://www.hkxytech.com/   | GMT/UTC +8
 