PHOENIX FO converters PSI-MOS-PROFIB/FO 660 T 2708287
Phoenix Contact's roots are in Germany. Our headquarters are in Blomberg. Originally founded in Essen in 1923, we have grown over the years. This is true not only with regard to production and technology, but also in terms of the variety of products and business units. Learn more about our business areas and discover more about the members of the Executive Board on our website.
Orderkey | 2708287 |
---|
Packing unit | 1 pc |
---|
Catalog page | Page 325 (C-6-2017) |
---|
GTIN | 4017918973988 |
---|
Weight per Piece (excluding packing) | 191.380 g |
---|
Custom tariff number | 85176200 |
---|
Country of origin | DE (Germany) |
---|
Dimensional drawing |
|
---|
Width | 35 mm |
---|
Height | 99 mm |
---|
Depth | 106 mm |
---|
Ambient temperature (operation) | -20 °C ... 60 °C |
---|
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
---|
Permissible humidity (operation) | 30 % ... 95 % (non-condensing) |
---|
Altitude | 5000 m (For restrictions see manufacturer's declaration) |
---|
Degree of protection | IP20 |
---|
Noise immunity | EN 61000-6-2:2005 |
---|
Bit delay | ≤ 1 bit |
---|
Bit distortion, input | ± 35 % (permitted) |
---|
Bit distortion, output | < 6.25 % |
---|
Electrical isolation | VCC // RS-485 |
---|
Test voltage data interface/power supply | 1.5 kVrms(50 Hz, 1 min.) |
---|
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
---|
Noise emission | EN 55011 |
---|
Net weight | 191.38 g |
---|
Housing material | PA 6.6-FR |
---|
Color | green |
---|
MTBF | 201 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
---|
| 42 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) |
---|
MTTF | 213 Years (SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week, 8 hours a day)) |
---|
| 150 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day)) |
---|
| 86 Years (SN 29500 standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day)) |
---|
Conformance | CE-compliant |
---|
ATEX | II 3 G Ex nA nC IIC T4 Gc X (Please follow the special installation instructions in the documentation!) |
---|
| II (2) G [Ex op is Gb] IIC (PTB 06 ATEX 2042 U) (Please follow the special installation instructions in the documentation!) |
---|
| II (2) D [Ex op is Db] IIIC (PTB 06 ATEX 2042 U) (Please follow the special installation instructions in the documentation!) |
---|
UL, USA/Canada | Class I, Zone 2, AEx nc IIC T5 |
---|
| Class I, zone 2, Ex nC nL IIC T5 X |
---|
| Class I, Div. 2, Groups A, B, C, D |
---|
Nominal supply voltage | 24 V DC (With UL approval) |
---|
Supply voltage range | 18 V DC ... 30 V DC |
---|
Max. current consumption | 130 mA |
---|
Typical current consumption | 100 mA (24 V DC) |
---|
Connection method | COMBICON plug-in screw terminal block |
---|
Interface 1 | PROFIBUS acc. to IEC 61158, RS-485 2-wire, half duplex, automatic control |
---|
Interface | PROFIBUS |
---|
Operating mode | Semi-duplex |
---|
Connection method | D-SUB-9 female connector |
---|
File format/coding | UART (11 Bit, NRZ) |
---|
Data direction switching | Automatic control |
---|
Transmission medium | Copper |
---|
Transmission length | ≤ 1200 m (depending on the data rate, with shielded, twisted pair data cable) |
---|
Conductor cross section solid min. | 0.2 mm² |
---|
Conductor cross section solid max. | 2.5 mm² |
---|
Conductor cross section flexible min. | 0.2 mm² |
---|
Conductor cross section flexible max. | 2.5 mm² |
---|
Conductor cross section AWG min. | 24 |
---|
Conductor cross section AWG max. | 14 |
---|
Serial transmission speed | ≤ 12 Mbps |
---|
Transmit capacity, minimum | -3 dBm (980/1000 µm) |
---|
| -15.4 dBm (200/230 µm) |
---|
Minimum receiver sensitivity | -30 dBm |
---|
Overrange receiver | -3 dBm (980/1000 µm) |
---|
Wavelength | 660 nm |
---|
Transmission length incl. 3 dB system reserve | 70 m (With F-P 980/1000 230 dB/km with quick mounting connector) |
---|
| 400 m (With F-K 200/230 10 dB/km with quick mounting connector) |
---|
Transmission medium | Polymer fiber |
---|
| PCF fiber |
---|
Transmission protocol | Protocol-transparent to the RS-485 interface |
---|
Connection method | F-SMA |
---|
Output name | Relay output |
---|
Output description | Alarm output |
---|
Number of outputs | 1 |
---|
Maximum switching voltage | 60 V DC |
---|
| 42 V AC |
---|
Limiting continuous current | 0.46 A |
---|
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
---|
Type of test | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 |
---|
Test result | 5g, 10...150 Hz, 2.5 h, in XYZ direction |
---|
Type of test | Shock in acc. with EN 60068-2-27/IEC 60068-2-27 |
---|
Test result | 15g, 11 ms period, half-sine shock pulse |
---|
Noise emission | EN 55011 |
---|
Noise immunity | EN 61000-6-2:2005 |
---|
Free from substances that could impair the application of coating | according to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard |
---|
Connection in acc. with standard | CUL |
---|
Standards/regulations | EN 61000-4-2 |
---|
Contact discharge | ± 6 kV |
---|
Standards/regulations | EN 61000-4-3 |
---|
| EN 61000-4-4 |
---|
Comments | Criterion B |
---|
Standards/regulations | EN 61000-4-5 |
---|
Signal | ± 1 kV |
---|
Standards/regulations | EN 55011 |
---|
| EN 61000-4-6 |
---|
Shock | 15g in all directions in acc. with IEC 60068-2-27 |
---|
Vibration (operation) | in acc. with IEC 60068-2-6: 5g, 150 Hz |
---|
Conformance | CE-compliant |
---|
ATEX | II 3 G Ex nA nC IIC T4 Gc X |
---|
| II (2) G [Ex op is Gb] IIC (PTB 06 ATEX 2042 U) |
---|
| II (2) D [Ex op is Db] IIIC (PTB 06 ATEX 2042 U) |
---|
UL, USA/Canada | Class I, Zone 2, AEx nc IIC T5 |
---|
| Class I, zone 2, Ex nC nL IIC T5 X |
---|
| Class I, Div. 2, Groups A, B, C, D |
---|
DNV GL-Temperature | B |
---|
DNV GL-Humidity | A |
---|
DNV GL-Vibration | A |
---|
DNV GL-EMC | B |
---|
DNV GL-Enclosure | Required protection according to the Rules shall be provided upon installation on board |
---|
Noxious gas test | ISA-S71.04-1985 G3 Harsh Group A |
---|
REACh SVHC | Lead 7439-92-1 |
---|
China RoHS | Environmentally Friendly Use Period = 50 |
---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
---|
Contact insert, Range of articles: VARIOCON, Contact insert, housing material: PA 6.6, number of positions: 8, nom. voltage: 160, rated current: 10 A, Connection method: Screw connection, Type of contact: Pin. Connectors may only be connected/disconnected when under no load..
Windy Wang
HONGKONG XIEYUAN TECH CO., LIMITED
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com
Website: http://www.hkxytech.com/ | GMT/UTC +8