PHOENIX FO converters PSI-MOS-RS485W2/FO 850 T 2708326
Phoenix Contact's roots are in Germany. Our headquarters are in Blomberg. Originally founded in Essen in 1923, we have grown over the years. This is true not only with regard to production and technology, but also in terms of the variety of products and business units. Learn more about our business areas and discover more about the members of the Executive Board on our website.
Contact insert, Range of articles: VARIOCON, Contact insert, housing material: PA 6.6, number of positions: 8, nom. voltage: 160, rated current: 10 A, Connection method: Screw connection, Type of contact: Pin. Connectors may only be connected/disconnected when under no load..
Orderkey | 2708326 |
---|
Packing unit | 1 pc |
---|
Catalog page | Page 329 (C-6-2017) |
---|
GTIN | 4017918974022 |
---|
Weight per Piece (excluding packing) | 210.080 g |
---|
Custom tariff number | 85176200 |
---|
Country of origin | DE (Germany) |
---|
Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
---|
Width | 35 mm |
---|
Height | 99 mm |
---|
Depth | 105 mm |
---|
Ambient temperature (operation) | -20 °C ... 60 °C |
---|
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
---|
Permissible humidity (operation) | 30 % ... 95 % (non-condensing) |
---|
Altitude | 5000 m (For restrictions see manufacturer's declaration) |
---|
Degree of protection | IP20 |
---|
Noise immunity | EN 61000-6-2:2005 |
---|
Bit delay | ≤ 1 bit |
---|
Bit distortion, input | ± 35 % (permitted) |
---|
Bit distortion, output | < 6.25 % |
---|
Electrical isolation | VCC // RS-485 |
---|
Test voltage data interface/power supply | 1.5 kVrms(50 Hz, 1 min.) |
---|
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
---|
Noise emission | EN 55011 |
---|
Net weight | 210.08 g |
---|
Housing material | PA 6.6-FR |
---|
Color | green |
---|
MTBF | 159 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
---|
| 24 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) |
---|
Conformance | CE-compliant |
---|
ATEX | II 3 G Ex nA nC IIC T4 Gc X (Please follow the special installation instructions in the documentation!) |
---|
| II (2) G [Ex op is Gb] IIC (PTB 06 ATEX 2042 U) (Please follow the special installation instructions in the documentation!) |
---|
| II (2) D [Ex op is Db] IIIC (PTB 06 ATEX 2042 U) (Please follow the special installation instructions in the documentation!) |
---|
UL, USA/Canada | Class I, Zone 2, AEx nc IIC T5 |
---|
| Class I, zone 2, Ex nC nL IIC T5 X |
---|
| Class I, Div. 2, Groups A, B, C, D |
---|
Nominal supply voltage | 24 V DC (With UL approval) |
---|
Supply voltage range | 18 V DC ... 30 V DC |
---|
Max. current consumption | 130 mA |
---|
Typical current consumption | 120 mA (24 V DC) |
---|
Connection method | COMBICON plug-in screw terminal block |
---|
Interface 1 | RS-485 interface, 2-wire |
---|
Operating mode | Semi-duplex |
---|
Connection method | Pluggable screw connection |
---|
File format/coding | UART (11/10 bit switchable; NRZ), slip-tolerant |
---|
Data direction switching | Automatic control |
---|
Transmission medium | Copper |
---|
Transmission length | ≤ 1200 m (depending on the data rate, with shielded, twisted data cable) |
---|
Termination resistor | 390 Ω |
---|
| 220 Ω |
---|
| 390 Ω (Can be connected) |
---|
Conductor cross section solid min. | 0.2 mm² |
---|
Conductor cross section solid max. | 2.5 mm² |
---|
Conductor cross section flexible min. | 0.2 mm² |
---|
Conductor cross section flexible max. | 2.5 mm² |
---|
Conductor cross section AWG min. | 24 |
---|
Conductor cross section AWG max. | 14 |
---|
Serial transmission speed | 4.8/ 9.6/ 19.2/ 38.4/ 57.6/ 75/ 93.75/ 115.2/ 136/ 187.5/ 375/ 500 kbps |
---|
Transmit capacity, minimum | -4 dBm (200/230 µm) |
---|
| -17.6 dBm (50/125 µm) |
---|
| -14 dBm (62,5/125 µm) |
---|
Minimum receiver sensitivity | -32.5 dBm (50/125 µm) |
---|
| -32.5 dBm (62,5/125 µm) |
---|
| -32.1 dBm (200/230 µm) |
---|
Overrange receiver | -3 dBm (200/230 µm) |
---|
Wavelength | 850 nm |
---|
Transmission length incl. 3 dB system reserve | 2800 m (with F-K 200/230 8 dB/km with quick mounting connector) |
---|
| 4200 m (with F-G 50/125 2.5 dB/km) |
---|
| 3300 m (with F-G 62,5/125 3.0 dB/km) |
---|
Transmission medium | PCF fiber |
---|
| Multi-mode fiberglass |
---|
Transmission protocol | Protocol-transparent to the RS-485 interface |
---|
Connection method | B-FOC (ST®) |
---|
Output name | Relay output |
---|
Output description | Alarm output |
---|
Number of outputs | 1 |
---|
Maximum switching voltage | 60 V DC |
---|
| 42 V AC |
---|
Limiting continuous current | 0.46 A |
---|
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
---|
Type of test | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 |
---|
Test result | 5g, 10...150 Hz, 2.5 h, in XYZ direction |
---|
Type of test | Shock in acc. with EN 60068-2-27/IEC 60068-2-27 |
---|
Test result | 15g, 11 ms period, half-sine shock pulse |
---|
Noise emission | EN 55011 |
---|
Noise immunity | EN 61000-6-2:2005 |
---|
Free from substances that could impair the application of coating | according to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard |
---|
Connection in acc. with standard | CUL |
---|
Standards/regulations | EN 61000-4-2 |
---|
Contact discharge | ± 6 kV |
---|
Standards/regulations | EN 61000-4-3 |
---|
| EN 61000-4-4 |
---|
Comments | Criterion B |
---|
Standards/regulations | EN 61000-4-5 |
---|
Signal | ± 1 kV |
---|
Standards/regulations | EN 55011 |
---|
| EN 61000-4-6 |
---|
Shock | 15g in all directions in acc. with IEC 60068-2-27 |
---|
Vibration (operation) | in acc. with IEC 60068-2-6: 5g, 150 Hz |
---|
Conformance | CE-compliant |
---|
ATEX | II 3 G Ex nA nC IIC T4 Gc X |
---|
| II (2) G [Ex op is Gb] IIC (PTB 06 ATEX 2042 U) |
---|
| II (2) D [Ex op is Db] IIIC (PTB 06 ATEX 2042 U) |
---|
UL, USA/Canada | Class I, Zone 2, AEx nc IIC T5 |
---|
| Class I, zone 2, Ex nC nL IIC T5 X |
---|
| Class I, Div. 2, Groups A, B, C, D |
---|
DNV GL-Temperature | B |
---|
DNV GL-Humidity | A |
---|
DNV GL-Vibration | A |
---|
DNV GL-EMC | B |
---|
DNV GL-Enclosure | Required protection according to the Rules shall be provided upon installation on board |
---|
Noxious gas test | ISA-S71.04-1985 G3 Harsh Group A |
---|
Shipbuilding approval | DNV GL |
---|
Windy Wang
HONGKONG XIEYUAN TECH CO., LIMITED
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com