PHOENIX MINI MCR-2-RTD-UI-PT 2902052 PHOENIX CONTACT Resistance thermometer measuring transducer
Phoenix Contact's roots are in Germany. Our headquarters are in Blomberg. Originally founded in Essen in 1923, we have grown over the years. This is true not only with regard to production and technology, but also in terms of the variety of products and business units. Learn more about our business areas and discover more about the members of the Executive Board on our website.
Contact insert, Range of articles: VARIOCON, Contact insert, housing material: PA 6.6, number of positions: 8, nom. voltage: 160, rated current: 10 A, Connection method: Screw connection, Type of contact: Pin. Connectors may only be connected/disconnected when under no load..
Orderkey | 2902052 |
---|
Packing unit | 1 pc |
---|
Note | Made to Order (non-returnable) |
---|
Catalog page | Page 80 (C-5-2017) |
---|
GTIN | 4046356652094 |
---|
Weight per Piece (excluding packing) | 110.000 g |
---|
Custom tariff number | 85437090 |
---|
Country of origin | DE (Germany) |
---|
Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
---|
Width | 6.2 mm |
---|
Height | 110.5 mm |
---|
Depth | 120.5 mm |
---|
Ambient temperature (operation) | -40 °C ... 70 °C |
---|
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
---|
Configurable/programmable | Yes |
---|
Sensor types (RTD) that can be used | Pt, Ni, Cu sensors |
---|
Linear resistance measuring range | 0 Ω ... 4000 Ω (Minimum measuring span: 10% of the selected measuring range) |
---|
Sensor input current | approx. 200 µA |
---|
Temperature measuring range | -200 °C ... 850 °C (Range depends on sensor type, range can be set freely via software or in increments from -150°C to 850°C via DIP switches) |
---|
Connection technology | 2, 3, 4-wire |
---|
Number of outputs | 1 |
---|
Configurable/programmable | Yes |
---|
Voltage output signal | 0 V ... 5 V (via DIP switch) |
---|
| 1 V ... 5 V (via DIP switch) |
---|
| 0 V ... 10 V (via DIP switch) |
---|
| 10 V ... 0 V (via DIP switch) |
---|
| 0 V ... 10.5 V (can be set via software) |
---|
Current output signal | 0 mA ... 20 mA (via DIP switch) |
---|
| 4 mA ... 20 mA (via DIP switch) |
---|
| 20 mA ... 0 mA (via DIP switch) |
---|
| 20 mA ... 4 mA (via DIP switch) |
---|
| 0 mA ... 21 mA (can be set via software) |
---|
Max. output voltage | approx. 12.3 V |
---|
Max. output current | 24.6 mA |
---|
Short-circuit current | < 31.5 mA |
---|
Load/output load voltage output | ≥ 10 kΩ |
---|
Load/output load current output | ≤ 600 Ω (at 20 mA) |
---|
Ripple | < 10 mVrms |
---|
| < 10 mVrms(at 600 Ω) |
---|
Supply voltage range | 9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715)) |
---|
Typical current consumption | 32 mA (24 V DC) |
---|
| 63 mA (12 V DC) |
---|
Power consumption | ≤ 850 mW (at IOUT= 20 mA, 9.6 V DC, 600 Ω load) |
---|
Connection method | Push-in connection |
---|
Single conductor/terminal point, solid, with ferrule, min. | 0.14 mm² |
---|
Single conductor/terminal point, solid, with ferrule, max. | 2.5 mm² |
---|
Single conductor/terminal point, solid, without ferrule, min. | 0.14 mm² |
---|
Single conductor/terminal point, solid, without ferrule, max. | 2.5 mm² |
---|
Conductor cross section flexible min. | 0.14 mm² |
---|
Conductor cross section flexible max. | 2.5 mm² |
---|
Min. AWG conductor cross section, flexible | 24 |
---|
Max. AWG conductor cross section, flexible | 12 |
---|
Stripping length | 10 mm |
---|
Transmission error resistance thermometer | 0.1 % * 350 K / set measuring range; 0.1 % > 350 K (Pt/Ni) |
---|
| 0.3 % * 200 K / set measuring range; 0.3 % > 200 K (Cu) |
---|
Transmission error resistance-type sensor | 2 Ω |
---|
Maximum temperature coefficient | 0.01 %/K |
---|
Protective circuit | Transient protection |
---|
Electrical isolation | Reinforced insulation in accordance with IEC 61010-1 |
---|
Overvoltage category | II |
---|
Degree of pollution | 2 |
---|
Rated insulation voltage | 300 V (effective) |
---|
Test voltage, input/output/supply | 3 kV (50 Hz, 1 min.) |
---|
Electromagnetic compatibility | Conformance with EMC directive |
---|
Noise emission | EN 61000-6-4 |
---|
Noise immunity | EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
---|
Housing material | PBT |
---|
Mounting position | any |
---|
Assembly instructions | The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715. |
---|
Conformance | CE-compliant |
---|
ATEX | II 3 G Ex nA IIC T4 Gc X |
---|
UL, USA/Canada | UL 508 Listed |
---|
| Class I, Div. 2, Groups A, B, C, D T6 |
---|
| Class I, Zone 2, Group IIC T6 |
---|
Certificate of classification | DNV GL 14445-15HH |
---|
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 |
---|
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 |
---|
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 |
---|
Designation | Electromagnetic RF field |
---|
Standards/regulations | EN 61000-4-3 |
---|
Typical deviation from the measuring range final value | 0.06 % |
---|
Designation | Fast transients (burst) |
---|
Standards/regulations | EN 61000-4-4 |
---|
Typical deviation from the measuring range final value | 0.1 % |
---|
Designation | Conducted interferences |
---|
Standards/regulations | EN 61000-4-6 |
---|
Typical deviation from the measuring range final value | 0.07 % |
---|
Electromagnetic compatibility | Conformance with EMC directive |
---|
Noise emission | EN 61000-6-4 |
---|
Standards/regulations | EN 61000-4-2 |
---|
Designation | Electromagnetic RF field |
---|
Standards/regulations | EN 61000-4-3 |
---|
| EN 61000-4-4 |
---|
| EN 61000-4-5 |
---|
Designation | Conducted interferences |
---|
Standards/regulations | EN 61000-4-6 |
---|
Electrical isolation | Reinforced insulation in accordance with IEC 61010-1 |
---|
Conformance | CE-compliant |
---|
ATEX | II 3 G Ex nA IIC T4 Gc X |
---|
UL, USA/Canada | UL 508 Listed |
---|
| Class I, Div. 2, Groups A, B, C, D T6 |
---|
| Class I, Zone 2, Group IIC T6 |
---|
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 |
---|
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 |
---|
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 |
---|
Windy Wang
HONGKONG XIEYUAN TECH CO., LIMITED
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com
Website: http://www.hkxytech.com/ | GMT/UTC +8