Phoenix Contact QUINT-PS-100-240AC/24DC/ 2.5 2938578 PHOENIX CONTACT Power supply unit With Good Price In Stock
Phoenix Contact's roots are in Germany. Our headquarters are in Blomberg. Originally founded in Essen in 1923, we have grown over the years. This is true not only with regard to production and technology, but also in terms of the variety of products and business units. Learn more about our business areas and discover more about the members of the Executive Board on our website.
Contact insert, Range of articles: VARIOCON, Contact insert, housing material: PA 6.6, number of positions: 8, nom. voltage: 160, rated current: 10 A, Connection method: Screw connection, Type of contact: Pin. Connectors may only be connected/disconnected when under no load.
Orderkey | 2938578 |
---|
Packing unit | 1 pc |
---|
Catalog page | Page 480 (IF-2007) |
---|
GTIN | 4017918890513 |
---|
Weight per Piece (excluding packing) | 850.000 g |
---|
Custom tariff number | 85044030 |
---|
Country of origin | TH (Thailand) |
---|
Width | 55 mm |
---|
Height | 130 mm |
---|
Depth | 125 mm |
---|
Width with alternative assembly | 122 mm |
---|
Height with alternative assembly | 130 mm |
---|
Depth with alternative assembly | 58 mm |
---|
Degree of protection | IP20 |
---|
Ambient temperature (operation) | -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) |
---|
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
---|
Max. permissible relative humidity (operation) | 95 % (at 25 °C, non-condensing) |
---|
Degree of pollution | 2 |
---|
Nominal input voltage range | 100 V AC ... 240 V AC |
---|
Input voltage range | 85 V AC ... 264 V AC |
---|
| 90 V DC ... 350 V DC |
---|
AC frequency range | 45 Hz ... 65 Hz |
---|
Frequency range DC | 0 Hz |
---|
Discharge current to PE | < 3.5 mA |
---|
Current consumption | approx. 0.86 A (120 V AC) |
---|
| approx. 0.47 A (230 V AC) |
---|
Nominal power consumption | 67 W |
---|
Inrush surge current | < 20 A (typical) |
---|
Mains buffering | > 30 ms (120 V AC) |
---|
| > 130 ms (230 V AC) |
---|
Input fuse | 5 A (slow-blow, internal) |
---|
Choice of suitable circuit breakers | 6 A ... 16 A (Characteristics B, C, D, K) |
---|
Type of protection | Transient surge protection |
---|
Protective circuit/component | Varistor |
---|
Nominal output voltage | 24 V DC ±1 % |
---|
Setting range of the output voltage (USet) | 22.5 V DC ... 28.5 V DC |
---|
Nominal output current (IN) | 2.5 A (up to 60°C) |
---|
POWER BOOST (IBoost) | 3.75 A |
---|
Derating | 60 °C ... 70 °C (2.5%/K) |
---|
Connection in parallel | Yes, for redundancy and increased capacity |
---|
Connection in series | yes |
---|
Feedback resistance | 35 V DC |
---|
Protection against surge voltage on the output | ≤ 35 V DC |
---|
Max. capacitive load | unlimited |
---|
Active current limitation | Approx. IBOOST= 3.75 A (for short-circuit) |
---|
Control deviation | < 1 % (change in load, static 10 % ... 90 %) |
---|
| < 2 % (change in load, dynamic 10 % ... 90 %) |
---|
| < 0.1 % (change in input voltage ±10 %) |
---|
Residual ripple | < 10 mVPP(with nominal values) |
---|
Output power | 60 W |
---|
Typical response time | < 1 s |
---|
Peak switching voltages nominal load | < 40 mVPP(20 MHz) |
---|
Maximum power dissipation in no-load condition | < 2 W |
---|
Power loss nominal load max. | < 8 W |
---|
Net weight | 0.85 kg |
---|
Operating voltage display | Green LED |
---|
Efficiency | > 86 % |
---|
Insulation voltage input/output | 4 kV AC (type test) |
---|
| 2 kV AC (routine test) |
---|
Insulation voltage input / PE | 3.5 kV AC (type test) |
---|
| 2 kV AC (routine test) |
---|
Insulation voltage output / PE | 500 V DC (routine test) |
---|
Protection class | I (with PE connection) |
---|
Degree of protection | IP20 |
---|
MTBF (IEC 61709, SN 29500) | > 500000 h |
---|
Mounting position | horizontal DIN rail NS 35, EN 60715 |
---|
Assembly instructions | alignable: horizontally 0 mm, vertically 50 mm |
---|
Connection method | Pluggable screw connection |
---|
Conductor cross section solid min. | 0.2 mm² |
---|
Conductor cross section solid max. | 2.5 mm² |
---|
Conductor cross section flexible min. | 0.2 mm² |
---|
Conductor cross section flexible max. | 2.5 mm² |
---|
Conductor cross section AWG min. | 24 |
---|
Conductor cross section AWG max. | 12 |
---|
Stripping length | 7 mm |
---|
Screw thread | M3 |
---|
Connection method | Pluggable screw connection |
---|
Conductor cross section solid min. | 0.2 mm² |
---|
Conductor cross section solid max. | 2.5 mm² |
---|
Conductor cross section flexible min. | 0.2 mm² |
---|
Conductor cross section flexible max. | 2.5 mm² |
---|
Conductor cross section AWG min. | 24 |
---|
Conductor cross section AWG max. | 12 |
---|
Stripping length | 7 mm |
---|
Screw thread | M3 |
---|
Output name | DC OK active |
---|
Output description | UOUT> 0.9 x UN: High signal |
---|
Maximum switching voltage | ≤ 24 V |
---|
Output voltage | + 24 V DC (Signal) |
---|
Maximum inrush current | ≤ 40 mA |
---|
Continuous load current | ≤ 40 mA |
---|
Status display | "DC OK" LED green |
---|
Note on status display | UOUT< 0.9 x UN: LED flashing |
---|
Conductor cross section solid min. | 0.2 mm² |
---|
Conductor cross section solid max. | 2.5 mm² |
---|
Conductor cross section flexible min. | 0.2 mm² |
---|
Conductor cross section flexible max. | 2.5 mm² |
---|
Conductor cross section AWG min. | 24 |
---|
Conductor cross section AWG max. | 12 |
---|
Tightening torque, min | 0.5 Nm |
---|
Tightening torque max | 0.6 Nm |
---|
Screw thread | M3 |
---|
Output name | DC OK floating |
---|
Output description | Relay contact, UOUT> 0.9 x UN: Contact closed |
---|
Maximum switching voltage | ≤ 30 V AC/DC |
---|
Maximum inrush current | ≤ 1 A |
---|
Continuous load current | ≤ 1 A |
---|
Status display | "DC OK" LED green |
---|
Electromagnetic compatibility | Conformance with EMC directive 89/336/EC |
---|
Noise emission | EN 55011 (EN 55022) |
---|
Noise immunity | EN 61000-6-2:2005 |
---|
Connection in acc. with standard | CUL |
---|
Standards/regulations | EN 61000-4-2 |
---|
Contact discharge | 8 kV |
---|
Standards/regulations | EN 61000-4-3 |
---|
Frequency range | 80 MHz ... 1 GHz |
---|
Test field strength | 10 V/m |
---|
Standards/regulations | EN 61000-4-4 |
---|
| EN 61000-6-3 |
---|
| EN 61000-4-6 |
---|
Frequency range | 0.15 MHz ... 80 MHz |
---|
Voltage | 10 V |
---|
Standards/regulations | EN 61000-4-11 |
---|
Standard - Safety of transformers | EN 61558-2-17 |
---|
Standard - Electrical safety | EN 60950-1/VDE 0805 (SELV) |
---|
| EN 61558-2-17 |
---|
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
---|
Standard – Safety extra-low voltage | EN 60950-1 (SELV) |
---|
| EN 60204 (PELV) |
---|
Standard - Safe isolation | DIN VDE 0100-410 |
---|
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment | EN 50178 |
---|
Standard – Limitation of mains harmonic currents | EN 61000-3-2 |
---|
Standard - Equipment safety | GS (tested safety) |
---|
Shipbuilding approval | DNV GL (EMC A), ABS |
---|
UL approvals | UL/C-UL Recognized UL 60950-1 |
---|
| UL/C-UL listed UL 508 |
---|
| UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) |
---|
Shock | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
---|
Vibration (operation) | < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
---|
| 15 Hz ... 150 Hz, 2.3g, 90 min. |
---|
Information technology equipment - safety (CB scheme) | CB Scheme |
---|
Overvoltage category (EN 62477-1) | III |
---|
if you are intersted in more more product, Please feel free to contct below contact me :windy@hkxytech.com
Windy Wang
HONGKONG XIEYUAN TECH CO., LIMITED
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com
Website: http://www.hkxytech.com/ | GMT/UTC +8