Power Supply Unit
Phoenix Contact Power supply unit - QUINT-PS-100-240AC/24DC/40 - 2938879

Phoenix Contact Power supply unit - QUINT-PS-100-240AC/24DC/40 - 2938879

Model: 2938879

$1.00

Supplier: Phoenix Contact

Categories: Power Supply Unit

After sales service. If you have any questions, click here.

Product Description

Phoenix Contact Power supply unit - QUINT-PS-100-240AC/24DC/40 - 2938879


Phoenix Contact's roots are in Germany. Our headquarters are in Blomberg. Originally founded in Essen in 1923, we have grown over the years. This is true not only with regard to production and technology, but also in terms of the variety of products and business units. Learn more about our business areas and discover more about the members of the Executive Board on our website.

Contact insert, Range of articles: VARIOCON, Contact insert, housing material: PA 6.6, number of positions: 8, nom. voltage: 160, rated current: 10 A, Connection method: Screw connection, Type of contact: Pin. Connectors may only be connected/disconnected when under no load.


Key Commercial Data

Orderkey2938879
Packing unit1 pc
Catalog pagePage 563 (IF-2009)
GTIN4017918987091
Weight per Piece (excluding packing)3,500.000 g
Custom tariff number85044030
Country of originCN (China)


Dimensions

Width240 mm
Height130 mm
Depth125 mm
Width with alternative assembly122 mm
Height with alternative assembly130 mm
Depth with alternative assembly243 mm

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Max. permissible relative humidity (operation)95 % (at 25 °C, non-condensing)
Climatic class3K3 (in acc. with EN 60721)
Degree of pollution2

Input data

Nominal input voltage range110 V AC ... 240 V AC
Input voltage range85 V AC ... 264 V AC (Derating < 100 V DC: 2.5%/V)

90 V DC ... 350 V DC (Derating < 110 V DC: 2.5%/V)
AC frequency range45 Hz ... 65 Hz
Frequency range DC0 Hz
Current consumptionapprox. 12.5 A (120 V AC)

approx. 4.5 A (230 V AC)
Nominal power consumption1051 W
Inrush surge current< 15 A (typical)
Mains buffering> 20 ms (120 V AC)

> 20 ms (230 V AC)
Input fuse20 A (fast blow, internal)
Choice of suitable circuit breakers16 A ... 20 A (Characteristics B, C, D, K)
Type of protectionTransient surge protection
Protective circuit/componentVaristor

Output data

Nominal output voltage24 V DC ±1 %
Setting range of the output voltage (USet)22.5 V DC ... 28.5 V DC (> 24 V DC, constant capacity restricted)
Nominal output current (IN)40 A (-25 °C ... 60 °C)
POWER BOOST (IBoost)45 A (-25°C ... 40°C permanent )
Derating60 °C ... 70 °C (2.5%/K)
Connection in parallelYes, for redundancy and increased capacity
Connection in seriesyes
Feedback resistance35 V DC
Output overvoltage protection≤ 35 V DC
Max. capacitive loadunlimited
Active current limitationApprox. IBOOST= 45 A (for short-circuit)
Control deviation< 1 % (change in load, static 10 % ... 90 %)

< 2 % (change in load, dynamic 10 % ... 90 %)

< 0.1 % (change in input voltage ±10 %)
Residual ripple< 30 mVPP(with nominal values)
Output power960 W
Typical response time< 1 s
Peak switching voltages nominal load< 50 mVPP(20 MHz)
Maximum power dissipation in no-load condition28 W
Power loss nominal load max.80 W

General

Net weight3.5 kg
Operating voltage displayGreen LED
Efficiency> 92 % (for 230 V AC and nominal values)
Insulation voltage input/output3 kV AC (type test)

2 kV AC (routine test)
Insulation voltage input / PE3 kV AC (type test)

1.5 kV AC (routine test)
Insulation voltage output / PE500 V DC (routine test)
Protection classI (with PE connection)
Degree of protectionIP20
MTBF (IEC 61709, SN 29500)> 500000 h
Mounting positionhorizontal DIN rail NS 35, EN 60715
Assembly instructionsalignable: horizontally 0 mm, vertically 50 mm

Connection data, input

Connection methodScrew connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.6 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.4 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.10
Stripping length7 mm
Screw threadM3

Connection data, output

Connection methodScrew connection
Conductor cross section solid min.0.5 mm²
Conductor cross section solid max.16 mm²
Conductor cross section flexible min.0.5 mm²
Conductor cross section flexible max.10 mm²
Conductor cross section AWG min.20
Conductor cross section AWG max.6
Stripping length10 mm
Screw threadM4

Signaling

Output nameDC OK active
Output descriptionUOUT> 0.9 x UN: High signal
Maximum switching voltage≤ 24 V
Output voltage+ 24 V DC (Signal)
Maximum inrush current≤ 20 mA (short-circuit-proof)
Continuous load current≤ 20 mA
Status display"DC OK" LED green
Note on status displayUOUT< 0.9 x UN: LED flashing
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.6 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.4 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.10
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm
Screw threadM3
Output nameDC OK floating
Output descriptionRelay contact, UOUT> 0.9 x UN: Contact closed
Maximum switching voltage≤ 30 V AC/DC
Maximum inrush current≤ 1 A
Continuous load current≤ 1 A
Status display"DC OK" LED green

Standards and Regulations

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Noise emissionEN 55011 (EN 55022)
Noise immunityEN 61000-6-2:2005
Connection in acc. with standardCUL
Standards/regulationsEN 61000-4-2
Contact discharge8 kV
Standards/regulationsEN 61000-4-3
Frequency range80 MHz ... 1 GHz
Test field strength10 V/m
Frequency range1.4 GHz ... 2 GHz
Test field strength10 V/m
Standards/regulationsEN 61000-4-4

EN 61000-6-3

EN 61000-4-6
Frequency range0.15 MHz ... 80 MHz
Voltage10 V
Standards/regulationsEN 61000-4-11
Low Voltage DirectiveConformance with LV directive 2006/95/EC
Standard - Safety of transformersEN 61558-2-17
Standard - Electrical safetyEN 60950-1/VDE 0805 (SELV)

EN 61558-2-17
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltageEN 60950-1 (SELV)

EN 60204 (PELV)
Standard - Safe isolationDIN VDE 0100-410
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipmentEN 50178
Standard – Limitation of mains harmonic currentsEN 61000-3-2
Standard - Equipment safetyGS (tested safety)
Shipbuilding approvalDNV GL (EMC A), ABS
UL approvalsUL/C-UL listed UL 508

UL/C-UL Recognized UL 60950-1

UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)

15 Hz ... 150 Hz, 2.3g, 90 min.
Information technology equipment - safety (CB scheme)CB Scheme
Overvoltage category (EN 62477-1)III

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 25;

For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”


Please contact me if you are interested in our products.


Contact: Windy


Phone: +86-15972199006


WhatsApp: +86-15972199006


Skype: windy@hkxytech.com


Email:  windy@hkxytech.com


QQ: 2148816382




Related Products