IFM PN2094 Pressure sensors /Vacuum sensors With Good Price In Stock
Feature of PN2094
Two switching outputs, one of them programmable as IO-Link and one as analogue output
Red/green display for clear identification of the acceptable range
The process connection can be rotated for optimum alignment
With long-term stability thanks to high overload protection
Robust design for use in harsh industrial environments
Product characteristics PN2094 | |
---|---|
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Measuring range | -1...10 bar-14.6...145 psi-0.1...1 MPa |
Process connection | threaded connection G 1/4 internal thread (DIN EN ISO 1179-2) |
Application of PN2094 | |
Special feature | Gold-plated contacts |
Measuring element | ceramic-capacitive pressure measuring cell |
Application | for industrial applications |
Media | liquids and gases |
Medium temperature [°C] | -25...80 |
Min. bursting pressure | 150 bar2175 psi15 MPa |
Pressure rating | 75 bar1087 psi7.5 Mpa |
Vacuum resistance [mbar] | -1000 |
Type of pressure | relative pressure; vacuum |
Electrical data of IFM PN2094 | |
Operating voltage [V] | 18...30 DC; (to SELV/PELV) |
Current consumption [mA] | < 35 |
Min. insulation resistance [MΩ] | 100; (500 V DC) |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 0.3 |
Integrated watchdog | yes |
Inputs / outputs OF PN2094 | |
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Outputs OF PN2094 | |
Total number of outputs | 2 |
Output signal | switching signal; analogue signal; IO-Link; (configurable) |
Electrical design | PNP/NPN |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 250 |
Switching frequency DC [Hz] | < 500 |
Number of analogue outputs | 1 |
Analogue current output [mA] | 4...20; (scalable 1:5) |
Max. load [Ω] | 500 |
Analogue voltage output [V] | 0...10; (scalable 1:5) |
Min. load resistance [Ω] | 2000 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Measuring/setting range of PN2094 | |
Measuring range | -1...10 bar-14.6...145 psi-0.1...1 MPa |
Analogue start point | -1...8 bar-14.6...116 psi-0.1...0.8 MPa |
Analogue end point | 1...10 bar14.6...145 psi0.1...1 MPa |
Factory setting / CMPT = 2 | |
Set point SP | -0.94...10 bar-13.6...145 psi-0.094...1 MPa |
Reset point rP | -0.98...9.96 bar-14.2...144.4 psi-0.098...0.996 MPa |
Min. difference between SP and rP | 0.06 bar0.6 psi0.006 MPa |
In steps of | 0.02 bar0.2 psi0.002 MPa |
Status_B High Resolution / CMPT = 3 | |
Set point SP | -0.94...10 bar-13.6...145 psi-0.094...1 MPa |
Reset point rP | -0.98...9.96 bar-14.2...144.4 psi-0.098...0.996 MPa |
Min. difference between SP and rP | 0.05 bar0.6 psi0.005 MPa |
In steps of | 0.01 bar0.1 psi0.001 MPa |
Accuracy / deviations | |
Notes on the accuracy / deviation | switch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1% |
Switch point accuracy [% of the span] | < ± 0,4; (Turn down 1:1) |
Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting) |
Hysteresis deviation [% of the span] | < ± 0,1; (Turn down 1:1) |
Long-term stability [% of the span] | < ± 0,05; (Turn down 1:1; per 6 months) |
Temperature coefficient zero point [% of the span / 10 K] | < ± 0,2; (-0...80 °C) |
Temperature coefficient span [% of the span / 10 K] | < ± 0,2; (-0...80 °C) |
Response times | |
Response time [ms] | < 1.5 |
Delay time programmable dS, dr [s] | 0...50 |
Damping for the switching output dAP [s] | 0...4 |
Damping for the analogue output dAA [s] | 0...4 |
Max. response time analogue output [ms] | 3 |
Software / programming | |
Parameter setting options | hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output |
Interfaces | |
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 |
SIO mode | yes |
Required master port type | A; (wenn PIN 2 nicht verbunden: B) |
Supported DeviceIDs | Type of operationDeviceIDFactory setting / CMPT = 2463Status_B High Resolution / CMPT = 3974 |
Note | For further information please see the IODD PDF file under "Downloads" |
Factory setting / CMPT = 2 | |
Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
Min. process cycle time [ms] | 2.3 |
IO-Link resolution pressure [bar] | 0.01 |
IO-Link process data (cyclical) | functionbit lengthpressure14binary switching information2 |
IO-Link functions (acyclical) | application specific tag |
Status_B High Resolution / CMPT = 3 | |
Profiles | Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) |
Min. process cycle time [ms] | 3 |
IO-Link resolution pressure [bar] | 0.005 |
IO-Link process data (cyclical) | functionbit lengthpressure16device status4binary switching information2 |
IO-Link functions (acyclical) | application specific tag |
Operating conditions | |
Ambient temperature [°C] | -25...80 |
Storage temperature [°C] | -40...100 |
Protection | IP 65; IP 67 |
Tests / approvals | |
EMC | DIN EN 61000-6-2DIN EN 61000-6-3 |
Shock resistance | DIN EN 60068-2-2750 g (11 ms) |
Vibration resistance | DIN EN 60068-2-620 g (10...2000 Hz) |
MTTF [years] | 138 |
UL approval | UL Approval no.J012 |
Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data | |
Weight [g] | 239 |
Materials | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC |
Materials (wetted parts) | stainless steel (1.4404 / 316L); Al2O3 (ceramics); FKM |
Min. pressure cycles | 100 million |
Tightening torque [Nm] | 25...35; (recommended tightening torque; depends on lubrication, seal and pressure rating) |
Process connection | threaded connection G 1/4 internal thread (DIN EN ISO 1179-2) |
Restrictor element integrated | no (can be retrofitted) |
Displays / operating elements | |
Display | Display unit3 x LED, green (bar, psi, MPa)switching status2 x LED, yellowmeasured valuesalphanumeric display, red/green 4-digit |
if you are intersted in more Allen-Bradley product, Please feel free to contct below contact me :windy@hkxytech.com
Windy Wang
HONGKONG XIEYUAN TECH CO., LIMITED
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com
Website: http://www.hkxytech.com/ | GMT/UTC +8