IFM offers a wide range of electronic pressure sensors to meet the requirements of various industrial applications. The ceramic-capacitive measuring cell, tried and tested millions of times, is complemented by a stainless steel measuring cell with thin-film or thick-film wire strain gauges (series PK, PV, PT) and a piezoresistive measuring technique (for pneumatic applications). All units have robust housings and do not require moving parts such as pistons or springs. The result: The sensors are extremely shock and vibration resistant and operate without any wear or maintenance. The tried and tested ceramic-capacitive measuring cell is corrosion-resistant and long-term stable. Units with wire strain gauge in thick-film technology on a stainless steel measuring cell are distinguished by their very compact and robust design. They can be used in almost all industrial areas.
Product characteristics | |
---|---|
Output signal | switching signal; analog signal; IO-Link; (configurable) |
Measuring range | 0...100 bar0...1450 psi0...10 MPa |
Process connection | threaded connection 1/4" NPT Internal thread |
Application | |
System | gold-plated contacts |
Measuring element | ceramic-capacitive pressure measuring cell |
Application | for industrial applications |
Media | Liquids |
Conditionally suitable for | use in gases at pressures > 25 bar only on request |
Medium temperature [°C] | -25...80 |
Min. bursting pressure | 650 bar9400 psi65 MPa |
Pressure rating | 300 bar4350 psi30 Mpa |
Vacuum resistance [mbar] | -1000 |
Type of pressure | relative pressure |
MAWP (for applications according to CRN) [bar] | 125 |
Electrical data | |
Operating voltage [V] | 18...30 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA] | < 35 |
Min. insulation resistance [MΩ] | 100; (500 V DC) |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 0.3 |
Integrated watchdog | yes |
Inputs / outputs | |
Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
Outputs | |
Total number of outputs | 2 |
Output signal | switching signal; analog signal; IO-Link; (configurable) |
Electrical design | PNP/NPN |
Number of digital outputs | 2 |
Output function | normally open / closed; (configurable) |
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 250 |
Switching frequency DC [Hz] | < 500 |
Number of analog outputs | 1 |
Analog current output [mA] | 4...20; (scalable 1:5) |
Max. load [Ω] | 500 |
Analog voltage output [V] | 0...10; (scalable 1:5) |
Min. load resistance [Ω] | 2000 |
Short-circuit protection | yes |
Type of short-circuit protection | yes (non-latching) |
Overload protection | yes |
Measuring/setting range | |
Measuring range | 0...100 bar0...1450 psi0...10 MPa |
Analog start point | 0...80 bar0...1160 psi0...8 MPa |
Analog end point | 20...100 bar290...1450 psi2...10 MPa |
Factory setting / CMPT = 2 | |
Set point SP | 0.6...100 bar10...1450 psi0.06...10 MPa |
Reset point rP | 0.2...99.6 bar4...1444 psi0.02...9.96 MPa |
Min. difference between SP and rP | 0.6 bar6 psi0.06 MPa |
In steps of | 0.2 bar2 psi0.02 MPa |
Status_B High Resolution / CMPT = 3 | |
Set point SP | 0.6...100 bar9...1450 psi0.06...10 MPa |
Reset point rP | 0.2...99.6 bar3...1444 psi0.02...9.96 MPa |
Min. difference between SP and rP | 0.5 bar6 psi0.05 MPa |
In steps of | 0.1 bar1 psi0.01 MPa |
Accuracy / deviations | |
Notes on the accuracy / deviation | switch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1% |
Switch point accuracy [% of the span] | < ± 0,4; (Turn down 1:1) |
Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting) |
Hysteresis deviation [% of the span] | < ± 0,1; (Turn down 1:1) |
Long-term stability [% of the span] | < ± 0,05; (Turn down 1:1; per 6 months) |
Temperature coefficient zero point [% of the span / 10 K] | < ± 0,2; (-0...80 °C) |
Temperature coefficient span [% of the span / 10 K] | < ± 0,2; (-0...80 °C) |
Reaction times | |
Response time [ms] | < 1.5 |
Delay time programmable dS, dr [s] | 0...50 |
Damping for the switching output dAP [s] | 0...4 |
Damping for the analog output dAA [s] | 0...4 |
Max. response time analog output [ms] | 3 |
Software / programming | |
Parameter setting options | hysteresis / window; normally open / closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output |
Interfaces | |
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 |
SIO mode | yes |
Required master port class | A; (wenn PIN 2 nicht verbunden: B) |
Supported DeviceIDs | Type of operationDeviceIDFactory setting / CMPT = 2471Status_B High Resolution / CMPT = 3987 |
Note | For further information please see the IODD PDF file at "Downloads" |
Factory setting / CMPT = 2 | |
Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
Min. process cycle time [ms] | 2.3 |
IO-Link resolution pressure [bar] | 0.1 |
IO-Link process data (cyclical) | Functionbit lengthpressure14binary switching information2 |
IO-Link functions (acyclical) | application specific tag |
Status_B High Resolution / CMPT = 3 | |
Profiles | Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) |
Min. process cycle time [ms] | 3 |
IO-Link resolution pressure [bar] | 0.05 |
IO-Link process data (cyclical) | Functionbit lengthpressure16device status4binary switching information2 |
IO-Link functions (acyclical) | application specific tag |
Operating conditions | |
Ambient temperature [°C] | -25...80 |
Storage temperature [°C] | -40...100 |
Protection | IP 65; IP 67 |
Tests / approvals | |
EMC | DIN EN 61000-6-2DIN EN 61000-6-3 |
Shock resistance | DIN EN 60068-2-2750 g (11 ms) |
Vibration resistance | DIN EN 60068-2-620 g (10...2000 Hz) |
MTTF [years] | 138 |
UL approval | UL approval numberJ013 |
Pressure equipment directive | sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data | |
Weight [g] | 261 |
Material | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC |
Materials (wetted parts) | stainless steel (1.4404 / 316L); Al2O3 (ceramics); FKM |
Min. pressure cycles | 100 million |
Tightening torque [Nm] | > 50 |
Process connection | threaded connection 1/4" NPT Internal thread |
Restrictor element integrated | no (can be retrofitted) |
Displays / operating elements | |
Display | Display unit3 x LED, green (bar, psi, MPa)Switching status2 x LED, yellowMeasured valuesalphanumeric display, red/green 4-digit |
Remarks | |
Pack quantity | 1 pcs. |
If you need more IFM Pressure sensors / Vacuum sensors, please click the "Need a Quote" button to fill in your quotation. We will reply you within 24 hours. Thank you!
Any inquiry,Please feel free to contact: | ||
Windy Wang | ||
windy@hkxytech.com | ||
HONGKONG XIEYUAN TECH CO., LIMITED | ||
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China | ||
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 |