IFM Flush pressure sensor with display PI2794 PI-010-REA01-MFRKG/US/ /P
Robust stainless steel housing for use in the food and beverage industry
Hygienic, flush design
Resistant to high-pressure cleaning with aggressive cleaning agents
High temperature resistance and high protection rating
Programmable analogue and switching output
Product characteristics | |
---|---|
Output signal | switching signal; analogue signal; IO-Link; (configurable) |
Measuring range | -1...10 bar-14.5...145 psi-0.1...1 MPa |
Process connection | threaded connection G 1 external thread Aseptoflex Vario |
Application | |
Special feature | Gold-plated contacts |
Application | flush mountable for the food and beverage industry |
Media | viscous media and liquids with suspended particles; liquids and gases |
Medium temperature [°C] | -25...125; (145 max. 1h) |
Min. bursting pressure | 150 bar2175 psi15 MPa |
Pressure rating | 50 bar725 psi5 Mpa |
Vacuum resistance [mbar] | -1000 |
Type of pressure | relative pressure; vacuum |
No dead space | yes |
MAWP (for applications according to CRN) | 50 bar725 psi5 MPa |
Electrical data | |
Min. insulation resistance [MΩ] | 100; (500 V DC) |
Protection class | III |
Reverse polarity protection | yes |
Integrated watchdog | yes |
2-wire | |
Operating voltage [V] | 20...32 DC |
Current consumption [mA] | 3.6...21 |
Power-on delay time [s] | 1 |
3-wire | |
Operating voltage [V] | 18...32 DC |
Current consumption [mA] | < 45 |
Power-on delay time [s] | 0.5 |
Inputs / outputs | |
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Outputs | |
Total number of outputs | 2 |
Output signal | switching signal; analogue signal; IO-Link; (configurable) |
Electrical design | PNP/NPN |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (parameterisable) |
Number of analogue outputs | 1 |
Analogue current output [mA] | 4...20, invertible; (scalable) |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
2-wire | |
Max. load [Ω] | 300 |
3-wire | |
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 250 |
Switching frequency DC [Hz] | 125 |
Max. load [Ω] | (Ub - 10 V) / 20 mA |
Measuring/setting range | |
Measuring range | -1...10 bar-14.5...145 psi-0.1...1 MPa |
Set point SP | -0.98...10 bar-14.2...145 psi-0.098...1 MPa |
Reset point rP | -1...9.98 bar-14.5...144.7 psi-0.1...0.998 MPa |
Analogue start point | -1...7.5 bar-14.5...108.7 psi-0.1...0.75 MPa |
Analogue end point | 1.5...10 bar21.8...145 psi0.15...1 MPa |
In steps of | 0.01 bar0.1 psi0.001 MPa |
Factory setting | SP1 = 2.50 barrP1 = 2.30 barSP2 = 7.50 barrP2 = 7.30 barASP = 0.00 barAEP = 10.00 bar |
Accuracy / deviations | |
Switch point accuracy [% of the span] | < ± 0,2; (Turn down 1:1) |
Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
Characteristics deviation [% of the span] | < ± 0,2; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1) |
Linearity deviation [% of the span] | < ± 0,15; (Turn down 1:1) |
Hysteresis deviation [% of the span] | < ± 0,15; (Turn down 1:1) |
Long-term stability [% of the span] | < ± 0,1; (Turn down 1:1; per year) |
Temperature coefficient zero point [% of the span / 10 K] | < ± 0,05; (0...70 °C) |
Temperature coefficient span [% of the span / 10 K] | < ± 0,15; (0...70 °C) |
Response times | |
Damping for the switching output dAP [s] | 0...30 |
Damping for the analogue output dAA [s] | 0.01...99.99 |
2-wire | |
Step response time analogue output [ms] | 45 |
3-wire | |
Min. response time of switching output (dAP) [ms] | 3 |
Step response time analogue output [ms] | 7 |
Interfaces | |
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.0 |
Profiles | no profile |
SIO mode | yes |
Required master port type | A |
Process data analogue | 1 |
Process data binary | 2 |
Min. process cycle time [ms] | 2.3 |
Supported DeviceIDs | Type of operationDeviceIDDefault157 |
Operating conditions | |
Ambient temperature [°C] | -25...80 |
Storage temperature [°C] | -40...100 |
Protection | IP 67; IP 68; IP 69K |
Tests / approvals | |
EMC | DIN EN 61000-6-2DIN EN 61000-6-3 |
Shock resistance | DIN EN 60068-2-2750 g (11 ms) |
Vibration resistance | DIN EN 60068-2-620 g (10...2000 Hz) |
MTTF [years] | 160 |
Note on approval | factory certificate available as download at www.factory-certificate.ifm |
Mechanical data | |
Weight [g] | 351.8 |
Materials | stainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFA |
Materials (wetted parts) | ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE |
Min. pressure cycles | 100 million |
Process connection | threaded connection G 1 external thread Aseptoflex Vario |
Displays / operating elements | |
Display | Display unitLED, greenswitching statusLED, yellowfunction displayalphanumeric display, 4-digitmeasured valuesalphanumeric display, 4-digit |
Display unit | bar; psi; MPa; % of the span |
Remarks | |
Pack quantity | 1 pcs. |
Electrical connection | |
Connection | Connector: 1 x M12; Contacts: gold-plated |
Related Products
PI2798
PI2797
PI2793
PI2789
PI2898
PI2894
PI2799
PI2796
PI2795
PI2897
PI2893
PI2602
PI2896
PI2899
PI2715
PI2714
PI2717
PI2889
PI2814
PI2817
PI2815
Windy Wang
HONGKONG XIEYUAN TECH CO., LIMITED
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com
Website: http://www.hkxytech.com/ | GMT/UTC +8