IFM Flow monitor SI5007 SID10ADBFPKG/US-100
Reliable monitoring of liquids and gases in pipes
Variable process connection using adapters
Easy setting of the switch points for quick set-up
Robust stainless steel housing for use in harsh industrial environments
LED bar graph for indication of switch point and flow
Product characteristics | |
---|---|
Number of inputs and outputs | Number of digital outputs: 2 |
Process connection | M18 x 1,5 internal thread |
Application | |
Media | Liquids; Gases |
Medium temperature [°C] | -25...80 |
Pressure rating [bar] | 300 |
Liquids | |
Medium temperature [°C] | -25...80 |
Gases | |
Medium temperature [°C] | -25...80 |
Electrical data | |
Operating voltage [V] | 18...36 DC |
Current consumption [mA] | < 60 |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 10 |
Inputs / outputs | |
Number of inputs and outputs | Number of digital outputs: 2 |
Outputs | |
Total number of outputs | 2 |
Output signal | switching signal; IO-Link; (configurable) |
Electrical design | PNP |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] | 2.5 |
Permanent current rating of switching output DC [mA] | 250 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Measuring/setting range | |
Probe length L [mm] | 45 |
Liquids | |
Setting range [cm/s] | 3...300 |
Greatest sensitivity [cm/s] | 3...100 |
Gases | |
Setting range [cm/s] | 200...3000 |
Greatest sensitivity [cm/s] | 200...800 |
Temperature monitoring | |
Measuring range [°C] | 2...80 |
Resolution [°C] | 1 |
Accuracy / deviations | |
Repeatability [cm/s] | 1...5 |
Note on repeatability | for water 5...100 cm/s; 25 °CFactory setting |
Temperature drift [cm/s x 1/K] | 0.1; (for water 5...100 cm/s; 10...70 °C) |
Temperature gradient [K/min] | 300 |
Switch point accuracy [cm/s] | ± 2...± 10; (for water 5...100 cm/s; 25 °C; Factory setting) |
Hysteresis [cm/s] | 2...5; (for water 5...100 cm/s; 25 °C; Factory setting) |
Temperature monitoring | |
Switch point accuracy [K] | ± 3 (v > 5cm/s); (Liquids) |
Resolution [K] | 1 |
Repeatability [K] | 2 |
Response times | |
Response time [s] | 1...10 |
Liquids | |
Response time [s] | 1...10 |
Gases | |
Response time [s] | 1...10 |
Temperature monitoring | |
Response time [s] | 1...10 |
Software / programming | |
Adjustment of the switch point | pushbutton |
Interfaces | |
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 |
Profiles | Smart Sensor: Process Data Variable; Device Identification |
SIO mode | yes |
Required master port type | A |
Process data analogue | 2 |
Process data binary | 2 |
Min. process cycle time [ms] | 3 |
Supported DeviceIDs | Type of operationDeviceIDDefault53 |
Operating conditions | |
Ambient temperature [°C] | -25...80 |
Storage temperature [°C] | -25...100 |
Protection | IP 65; IP 67 |
Tests / approvals | |
EMC | DIN EN 60947-5-9 |
Shock resistance | DIN IEC 60068-2-2750 g (11 ms) |
Vibration resistance | DIN EN 60068-2-620 g (55...2000 Hz) |
MTTF [years] | 277 |
Mechanical data | |
Weight [g] | 254 |
Dimensions [mm] | M18 x 1.5 |
Thread designation | M18 x 1.5 |
Materials | stainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PC; PBT-GF20; EPDM/X |
Materials (wetted parts) | stainless steel (1.4404 / 316L); O-ring: FKM 80 Shore A |
Process connection | M18 x 1,5 internal thread |
Displays / operating elements | |
Display | function10 x LED, three-colour |
Remarks | |
Pack quantity | 1 pcs. |
Electrical connection | |
Connection | Connector: 1 x M12 |
Windy Wang
HONGKONG XIEYUAN TECH CO., LIMITED
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com
Website: http://www.hkxytech.com/ | GMT/UTC +8