IFM Pressure sensor with display PN7094 PN-010-RER14-QFRKG/US/ /V With Good Price In Ready Stock
Two switching outputs, one of them with IO-Link communication interface
Red/green display for clear identification of the acceptable range
The process connection can be rotated for optimum alignment
With long-term stability thanks to high overload protection
Robust design for use in harsh industrial environments
Product characteristics | |
---|---|
Output signal | switching signal; IO-Link; (configurable) |
Measuring range | -1...10 bar-14.5...145 psi-0.1...1 MPa |
Process connection | threaded connection G 1/4 internal thread |
Application | |
Special feature | Gold-plated contacts |
Measuring element | ceramic-capacitive pressure measuring cell |
Application | for industrial applications |
Media | liquids and gases |
Medium temperature [°C] | -25...80 |
Min. bursting pressure | 150 bar2175 psi15 MPa |
Pressure rating | 75 bar1087 psi7.5 Mpa |
Vacuum resistance [mbar] | -1000 |
Type of pressure | relative pressure; vacuum |
Electrical data | |
Operating voltage [V] | 18...30 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA] | < 35 |
Min. insulation resistance [MΩ] | 100; (500 V DC) |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | < 0.3 |
Integrated watchdog | yes |
Inputs / outputs | |
Number of inputs and outputs | Number of digital outputs: 2 |
Outputs | |
Total number of outputs | 2 |
Output signal | switching signal; IO-Link; (configurable) |
Electrical design | PNP/NPN |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] | 2.5 |
Permanent current rating of switching output DC [mA] | 150; (200 (...60 °C) 250 (...40 °C)) |
Switching frequency DC [Hz] | < 170 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Measuring/setting range | |
Measuring range | -1...10 bar-14.5...145 psi-0.1...1 MPa |
Factory setting / CMPT = 2 | |
Set point SP | -0.9...10 bar-13.5...145 psi-0.09...1 MPa |
Reset point rP | -0.95...9.95 bar-14...144.5 psi-0.095...0.995 MPa |
Min. difference between SP and rP | 0.05 bar1 psi0.005 MPa |
In steps of | 0.05 bar0.5 psi0.005 MPa |
Status_B High Resolution / CMPT = 3 | |
Set point SP | -0.92...10 bar-13.3...145 psi-0.092...1 MPa |
Reset point rP | -0.97...9.95 bar-14...144.3 psi-0.097...0.995 MPa |
Min. difference between SP and rP | 0.05 bar0.8 psi0.005 MPa |
In steps of | 0.01 bar0.1 psi0.001 MPa |
Accuracy / deviations | |
Switch point accuracy [% of the span] | < ± 0,5 |
Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
Hysteresis deviation [% of the span] | < ± 0,25 |
Long-term stability [% of the span] | < ± 0,05; (per 6 months) |
Temperature coefficient zero point [% of the span / 10 K] | < ± 0,2; (0...80 °C) |
Temperature coefficient span [% of the span / 10 K] | < ± 0,2; (0...80 °C) |
Response times | |
Response time [ms] | < 3 |
Delay time programmable dS, dr [s] | 0...50 |
Software / programming | |
Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping; Display unit |
Interfaces | |
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 |
SIO mode | yes |
Required master port type | A; (when pin 2 not connected: B) |
Supported DeviceIDs | Type of operationDeviceIDFactory setting / CMPT = 2403Status_B High Resolution / CMPT = 3601PN7004311 |
Note | For further information please see the IODD PDF file under "Downloads" |
Factory setting / CMPT = 2 | |
Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
Min. process cycle time [ms] | 2.3 |
IO-Link resolution pressure [bar] | 0.01 |
IO-Link resolution pressure [MPa] | 0.001 |
IO-Link process data (cyclical) | functionbit lengthpressure14binary switching information2 |
IO-Link functions (acyclical) | application specific tag |
Status_B High Resolution / CMPT = 3 | |
Profiles | Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) |
Min. process cycle time [ms] | 3 |
IO-Link resolution pressure [bar] | 0.005 |
IO-Link resolution pressure [MPa] | 0.0005 |
IO-Link process data (cyclical) | functionbit lengthpressure16device status4binary switching information2 |
IO-Link functions (acyclical) | application specific tag |
Operating conditions | |
Ambient temperature [°C] | -25...80 |
Storage temperature [°C] | -40...100 |
Protection | IP 65; IP 67 |
Tests / approvals | |
EMC | DIN EN 61000-6-2DIN EN 61000-6-3 |
Shock resistance | DIN EN 60068-2-2750 g (11 ms) |
Vibration resistance | DIN EN 60068-2-620 g (10...2000 Hz) |
MTTF [years] | 260 |
UL approval | UL Approval no.J001 |
Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data | |
Weight [g] | 241.7 |
Materials | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC |
Materials (wetted parts) | stainless steel (1.4404 / 316L); ceramics; FKM |
Min. pressure cycles | 100 million |
Tightening torque [Nm] | 25...35; (recommended tightening torque; depends on lubrication, seal and pressure rating) |
Process connection | threaded connection G 1/4 internal thread |
Displays / operating elements | |
Display | Display unit3 x LED, green (bar, psi, MPa)switching status2 x LED, yellowmeasured valuesalphanumeric display, red/green 4-digit |
Remarks | |
Pack quantity | 1 pcs. |
Electrical connection | |
Connection | Connector: 1 x M12; Contacts: gold-plated |
HONGKONG XIEYUAN TECH CO.,LTD, established in 7th Nov.,2012, a comprehensive corporation with its independent rights of export and import.. We are committed to providing customers with convenient and efficient industrial supplies services. From the product, price, logistics, service process for customers to improve procurement efficiency, reduce procurement costs, and grow together with customers.
Xieyuan sales of major brands are: Yokogawa, Siemens, ABB, Schneider, Emerson, Rosemount, Honeywell, Pepper+Fuchs, MTL, Fluke, Fisher, Endress+Hauser, Phoenix Contact, Weidmüller, Triconex, KROHNE, Dräger, Allen-Bradley, Omron, Eaton, SMC, Eaton, RAE, Testo, MSA, FESTO, Vega, Yaskawa, Danfoss, GE, Fisher, Hirschmann, IFM, Turck, MOXA, Foxboro etc.
Our wide range of products include Field Instruments, Field Communicator, Gas Detectors, Process Analyzers, Pressure Transmitters, Temperature Transmitters, Flow Meters, Inverters, Multimeters, Safety Barriers, Positioners, Controllers, Valves, Circuit Breakers, Sensors, DCS, PLC etc.
We endeavor to provide our customer with high quality, 100% original brand new products at competitive prices. Our targeting market includes Oil and Gas Industry, Refinery, Chemical, Mineral, Power and Energy, Ocean Engneering, Electricity, Food, Environment Protection and many other fields.
We operate in more than 50 countries around the world. There are: Singapore, Indonesia, Malaysia, Philippines, Vietnam, Thailand, South Korea, Kazakhstan, Bangladesh, United Arab Emirates, Saudi Arabia, Iran, Iraq, Kuwait, Oman, Qatar,Germany, Italy, Austria, UK, Nigeria, Pakistan, Egypt, USA, Chile, Brazil, Mexico etc.
CHINA MAINLAND ADDRESS:
7-A16,CAISHEN COMMERCIAL PLAZA, HANKOU RAILWAY STATION, WUHAN, CHINA.
All products will send out within 72 hours, Please feel free to contact us! Thanks
Windy Wang
HONGKONG XIEYUAN TECH CO., LIMITED
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com
Website: http://www.hkxytech.com/ | GMT/UTC +8