inductive sensors
IFM Magnetic-inductive flow meter SM0504 SMR11GGX50KG/US100

IFM Magnetic-inductive flow meter SM0504 SMR11GGX50KG/US100

Model: SM0504

$1.00

Supplier: IFM

Categories: inductive sensors

After sales service. If you have any questions, click here.

Product Description

IFM Magnetic-inductive flow meter SM0504 SMR11GGX50KG/US100


IFM SM0504 product picture


Product characteristics
Number of inputs and outputsNumber of analog outputs: 2
Measuring range6...1800 gph0.1...30 gpm
Process connectionthreaded connection G 1 DN25 flat seal
Application
Systemgold-plated contacts
Applicationfor industrial applications
Installationconnection to pipe by means of an adapter
MediaConductive liquids; water; water-based media
Note on mediaconductivity: ≥ 20 µS/cmviscosity: < 70 mm²/s (40 °C)
Medium temperature [°F]14...158
Pressure rating [bar]16
Pressure rating [psi]232
Electrical data
Operating voltage [V]18...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]95; (24 V)
Min. insulation resistance [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Inputs / outputs
Number of inputs and outputsNumber of analog outputs: 2
Outputs
Total number of outputs2
Output signalanalog signal
Number of analog outputs2
Analog current output [mA]4...20; (scalable)
Max. load [Ω]500
Overload protectionyes
Measuring/setting range
Measuring range6...1800 gph0.1...30 gpm
Display range-1902...1902 gph-31.7...31.7 gpm
Resolution2 gph0.05 gpm
Analog start point ASP0...1268 gph0...21.15 gpm
Analog end point AEP318...1800 gph5.3...30 gpm
In steps of2 gph0.05 gpm
Temperature monitoring
Measuring range [°F]-4...176
Resolution [°F]0.5
Analog start point [°F]-4...140.5
Analog end point [°F]31.5...176
In steps of [°F]0.5
Accuracy / deviations
Flow monitoring
Accuracy (in the measuring range)± (0,8 % MW + 0,5 % MEW)
Repeatability± 0,2% MEW
Temperature monitoring
Accuracy [K]± 4,5 (Q > 0,26 gpm)
Reaction times
Flow monitoring
Response time [s]0.15; (dAP = 0)
Damping for the switching output dAP [s]0...5
Temperature monitoring
Dynamic response T05 / T09 [s]T09 = 20 (Q > 0,26 gpm)
Operating conditions
Ambient temperature [°F]14...140
Storage temperature [°F]-13...176
ProtectionIP 67
Tests / approvals
EMCDIN EN 60947-5-9500 V withstand voltage (V DC)
Shock resistanceDIN IEC 68-2-2720 g (11 ms)
Vibration resistanceDIN IEC 68-2-65 g (10...2000 Hz)
MTTF [years]175
Pressure equipment directivesound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight [g]612
Materialstainless steel (1.4404 / 316L); PBT-GF20; PC; EPDM/X
Materials (wetted parts)stainless steel (1.4404 / 316L); Hastelloy; PEEK; FKM
Process connectionthreaded connection G 1 DN25 flat seal
Displays / operating elements
DisplayDisplay unit6 x LED, green (l/min, m³/h, gpm, gph, °C, °F)Measured valuesalphanumeric display, 4-digitProgrammingalphanumeric display, 4-digit
Display unitl/min; m³/h; gpm; gph; °C; °F
Remarks
RemarksMW = Measured valueMEW = Final value of the measuring range
Pack quantity1 pcs.
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated
Diagrams and graphs
Pressure loss
dPPressure lossQvolumetric flow quantity


Windy Wang
HONGKONG XIEYUAN TECH CO., LIMITED
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com
Website: http://www.hkxytech.com/ | GMT/UTC +8

Related Products