Honeywell Module
Honeywell FC-TSAOH-0220m Safe Analog Output FTA with HART interface (0 - 20 mA, 2 channels) With Best Price In Stock

Honeywell FC-TSAOH-0220m Safe Analog Output FTA with HART interface (0 - 20 mA, 2 channels) With Best Price In Stock

Model: FC-TSAOH-0220m

$1.00

Supplier: Honeywell

Categories: Honeywell Module

After sales service. If you have any questions, click here.

Product Description

Honeywell FC-TSAOH-0220m Safe Analog Output FTA with HART interface (0 - 20 mA, 2 channels) With Best Price In Stock


HONEYWELL FC-TSAOH-0220m


FC-TSAOH-0220m Honeywell Module Fast Delivery


Introduction


The Honeywell Safety Manager™ is a highly reliable, high-integrity safety system for safety-critical control applications. As part of Honeywell’s Experion™ PKS, integrated into PlantScape, or in stand-alone applications, Safety Manager forms the basis for functional safety, thus providing protection of persons, plant equipment, and the environment, combined with optimum availability for continuous plant operation. Safety Manager is a user-programmable, modular, microprocessor-based safety system, which can perform a wide range of high-integrity process control and safety instrumented functions, including: 


• High-integrity process control,

• Burner/boiler management systems, 

• Process safeguarding and emergency shutdown, 

• Turbine and compressor safeguarding, 

• Fire and gas detection systems, and 

• Pipeline monitoring.


The 10102/1/2 module has potentiometers for calibration purposes (P1, P2, P4, P5). The module can be calibrated using the calibration option of the 'View FSC system and process status' program, an external calibrator, an extender module and an extender flatcable.The analog input module scans the analog inputs, the 26 V output voltages, the internal supply voltages, and a reference voltage generated by a D/A converter. This D/A converter generates several reference voltages which are used to test the analog input module completely. The self-test includes a leakage test of the input filter as this could influence the accuracy of the analog input value. Within the configured process safety time, the analog inputs are tested for: • absolute accuracy, • correct conversion over full range, • crosstalk between inputs, and • output voltage of the 26 Vdc outputs. The 26 Vdc outputs are generated by the DC/DC converter and stabilized at 26 Vdc. They are therefore independent of the voltage of the incoming 24 Vdc.


10102/2/1 AI FC-TSAI-0410 Fail-Safe Analog Input, 4channels
10105/2/1 AI FC-TSAI-1620m Fail-Safe 0(4)-20mA Analog Input, 16channels
10105/2/1 AI FC-TSFIRE-1624 Fail-Safe Fire Detector Input with Line Monitoring, 24Vdc, 16channels
10105/2/1 AI FC-TSGAS-1624 Fail-Safe Gas-Flame Detector Input, 0-20mA, 16channels
10105/2/1 AI FC-TSHART-1620m Fail-Safe 0(4)-20mA Analog Input with HART Interface, 16channels
10205/2/1 AO FC-TSAO-0220m Fail-Safe 0(4)-20mA Analog Output, 2channels
10101/2/1 DI FC-TIDI-1624 Isolated Passive Digital Input, 24Vdc, 16channels
10101/2/1 DI FC-TSDI-16115 Fail-Safe Active/Passive Digital Input, 115Vac/dc, 16channels
10101/2/1 DI FC-TSDI-1624C Current limited Digital Input, 24Vdc, 16channels
10101/2/1 DI FC-TSDI-16UNI Fail-Safe Digital Input, 24/48Vdc, NAMUR, 16channels
10101/2/3 DI FC-TSDI-16UNI Fail-Safe Digital Input, 24/48Vdc, NAMUR, 16channels
10106/2/1 DI FC-TSDI-16UNI Fail-Safe Digital Input, 24/48Vdc, NAMUR, 16channels
10201/2/1 DO FC-TSDO-0824C Fail-Safe Digital Output, Current limited 24Vdc, 8channels
10201/2/1 DO FC-TRO-0824 Digital Output, Relay Contact, 8channels NO/NC
10201/2/1 DO FC-TSDO-0824 Fail-Safe Digital Output, 24Vdc, 8channels
10201/2/1 DO FC-TSRO-0824 Digital Output, Relay for AK5/6 Applications, 8channels
10206/2/1 DO FC-TDO-1624 Digital Output, 24Vdc, 16channels
10208/2/1 DO FC-TRO-1024 Digital Output, Relay Contact, 10 channels
10209/2/1 DO FC-TDO-1624 Digital Output, 24Vdc, 16channels
10215/2/1 DO FC-TSDO-0424 Fail-Safe Digital Output, 24Vdc, 4channels
10216/2/1 DO FC-TSDOL-0424C Fail-Safe Digital Output, Current limited 24Vdc, 4channels
10216/2/1 DO FC-TSDO-04UNI Fail-Safe Digital Output, 24/48/60/110Vdc, 4channels
RUSIO-3224 MIXED FC-IOTA-R24 SM RIO Remote Universal Safe 32 ch 24Vdc
SAI-0410 AI FC-TSAI-0410 Fail-Safe Analog Input, 4channels
SAI-1620m AI FC-TSAI-1620m Fail-Safe 0(4)-20mA Analog Input, 16channels
SAI-1620m AI FC-TSFIRE-1624 Fail-Safe Fire Detector Input with Line Monitoring, 24Vdc, 16channels
SAI-1620m AI FC-TSGAS-1624 Fail-Safe Gas-Flame Detector Input, 0-20mA, 16channels
SAI-1620m AI FC-TSHART-1620m Fail-Safe 0(4)-20mA Analog Input with HART Interface, 16channels
SAI-1620m AI FC-TSGASH-1624 Safe Gas -Flame detector input FTA (0 - 20 mA, 16 channels) with HART interface
SAO-0220m AO FC-TSAO-0220m Fail-Safe 0(4)-20mA Analog Output, 2channels
SAO-0220m AO FC-TSAOH-0220m Safe Analog Output FTA with HART interface (0 - 20 mA, 2 channels)
SDI-1624 DI FC-TIDI-1624 Isolated Passive Digital Input, 24Vdc, 16channels
SDI-1624 DI FC-TSDI-16115 Fail-Safe Active/Passive Digital Input, 115Vac/dc, 16channels
SDI-1624 DI FC-TSDI-1624 Safe Digital Input, 24Vdc, 16channels
SDI-1624 DI FC-TSDI-1624C Current limited Digital Input, 24Vdc, 16channels
SDI-1624 DI FC-TSDI-16UNI Fail-Safe Digital Input, 24/48Vdc, NAMUR, 16channels
SDI-1624 DI FC-TDOL-0724 Digital output FTA, loop monitoring (2A, 24Vdc, 7 channels)
SDI-1624 DI FC-TDOL-07120 Digital output FTA, loop monitoring (120 V, 7 channels)
SDI-1648 DI FC-TSDI-1648 Safe digital input FTA (48 Vdc, 16 channels)
SDI-1648 DI FC-TSDI-16UNI Fail-Safe Digital Input, 24/48Vdc, NAMUR, 16channels
SDIL-1608 DI FC-TSDI-16UNI Fail-Safe Digital Input, 24/48Vdc, NAMUR, 16channels
DO-1224 DO FC-TDO-1624 Digital Output, 24Vdc, 16channels
DO-1624 DO FC-TDO-1624 Digital Output, 24Vdc, 16channels
RO-1024 DO FC-TRO-1024 Digital Output, Relay Contact, 10 channels
SDO-04110 DO FC-TSDO-04UNI Fail-Safe Digital Output, 24/48/60/110Vdc, 4channels
SDO-0424 DO FC-TSDO-0424 Fail-Safe Digital Output, 24Vdc, 4channels
SDO-0448 DO FC-TSDO-04UNI Fail-Safe Digital Output, 24/48/60/110Vdc, 4channels
SDO-0824 DO FC-TSDO-0824C Fail-Safe Digital Output, Current limited 24Vdc, 8channels
SDO-0824 DO FC-TRO-0824 Digital Output, Relay Contact, 8channels NO/NC
SDO-0824 DO FC-TSDO-0824 Fail-Safe Digital Output, 24Vdc, 8channels
SDO-0824 DO FC-TSRO-0824 Digital Output, Relay for AK5/6 Applications, 8channels
SDO-0824 DO FC-TDOL-0724 Digital output FTA, loop monitoring (2A, 24Vdc, 7 channels)
SDO-0824 DO FC-TDOL-07120 Digital output FTA, loop monitoring (120 V, 7 channels)
SDO-0824 DO FC-TSRO-08UNI Digital output (relay) FTA for SIL3 applications, common power (8 channels)
SDOL-0424 DO FC-TSDOL-0424C Fail-Safe Digital Output, Current limited 24Vdc, 4channels
SDOL-0424 DO FC-TSDO-04UNI Fail-Safe Digital Output, 24/48/60/110Vdc, 4channels
SDOL-0448 DO FC-TSDO-04UNI Fail-Safe Digital Output, 24/48/60/110Vdc, 4channels



Windy Wang
HONGKONG XIEYUAN TECH CO., LIMITED  
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com
Website:  http://www.hkxytech.com/   | GMT/UTC +8


Related Products