Switch Amplifier KFA6-SR2-Ex2.W
2-channel isolated barrier
230 V AC supply
Dry contact or NAMUR inputs
Relay contact output
Line fault detection (LFD)
Reversible mode of operation
Up to SIL 2 acc. to IEC 61508/IEC 61511
   
Technical data of Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
  
General specifications of Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
 
Signal type Digital Input
  
Functional safety related parameters of Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
 
Safety Integrity Level (SIL) SIL 2
  
Supply of Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
 
Connection terminals 14, 15
Rated voltage 207 ... 253 V AC, 45 ... 65 Hz
Power dissipation 1.2 W
Power consumption max. 1.3 W
  
Input of Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
 
Connection side field side
Connection terminals 1+, 2+, 3-; 4+, 5+, 6-
Rated values acc. to EN 60947-5-6 (NAMUR)
Open circuit voltage/short-circuit current approx. 8 V DC / approx. 8 mA
Switching point/switching hysteresis 1.2 ... 2.1 mA / approx. 0.2 mA
Line fault detection breakage I ≤ 0.1 mA , short-circuit I > 6 mA
Pulse/Pause ratio min. 20 ms / min. 20 ms
  
Output of Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
 
Connection side control side
Connection output I: terminals 7, 8, 9 ; output II: terminals 10, 11, 12
Output I, II signal ; relay
Contact loading 253 V AC/2 A/cos φ > 0.7; 126.5 V AC/4 A/cos φ > 0.7; 40 V DC/2 A resistive load
Energized/De-energized delay approx. 20 ms / approx. 20 ms
Mechanical life 107 switching cycles
  
Transfer characteristics of Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
 
Switching frequency ≤ 10 Hz
  
Galvanic isolation of Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
 
Input/Output reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Input/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output/Output reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
   
Indicators/settings of Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
 
Display elements LEDs
Labeling space for labeling at the front
  
Directive conformity of Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
 
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Low voltage
Directive 2014/35/EU EN 61010-1:2010
  
Conformity of Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
 
Electromagnetic compatibility NE 21:2006
Degree of protection IEC 60529:2001
Input EN 60947-5-6:2000
  
Ambient conditions of Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
 
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
  
Mechanical specifications of Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
 
Degree of protection IP20
Connection screw terminals
Mass approx. 150 g
Dimensions 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
  
Data for application in connection with hazardous areas of Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
 
EU-Type Examination Certificate PTB 00 ATEX 2081
Marking Ex-Hexagon II (1)G [Ex ia Ga] IIC
Ex-Hexagon II (1)D [Ex ia Da] IIIC
Ex-Hexagon I (M1) [Ex ia Ma] I
Input Ex ia
Voltage 10.6 V
Current 19.1 mA
Power 51 mW (linear characteristic)
Supply
Maximum safe voltage 253 V AC (Attention! Um is no rated voltage.)
Output
Contact loading 253 V AC/2 A/cos φ > 0.7; 126.5 V AC/4 A/cos φ > 0.7; 40 V DC/2 A resistive load
Maximum safe voltage 253 V AC (Attention! The rated voltage can be lower.)
Galvanic isolation
Input/input not available
Input/Output safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Input/power supply safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-11:2012
  
International approvals of Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
 
FM approval
Control drawing 116-0035
UL approval
Control drawing 116-0145
CSA approval
Control drawing 116-0047
IECEx approval IECEx PTB 11.0031
Approved for [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I


 
General information of Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
 
Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
 
Classifications of Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
 
System Classcode
ECLASS 11.0 27210121
ECLASS 10.0.1 27210121
ECLASS 9.0 27210121
ECLASS 8.0 27210121
ECLASS 5.1 27210121
ETIM 8.0 EC001485
ETIM 7.0 EC001485
ETIM 6.0 EC001485
ETIM 5.0 EC001485
UNSPSC 12.1 32101514
 
 
   
Similar models of Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
 
HiC2821
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
 
HiC2822
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, 2 relay contact outputs, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
 
KFA6-DU-Ex1.D
Switch Amplifier, Timer Relay
1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact and transistor output, Adjustable output timer functions from 10 ms ... 60 min, Input frequency up to 80 Hz; pulse divider up to 1 kHz, Reset function, Configurable by keypad, Line fault detection (LFD)
 
KFA6-SOT2-Ex2
Switch Amplifier
2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
 
KFA6-SR-2.3L
Switch Amplifier
2-channel signal conditioner, 115/230 V AC supply, 3-wire PNP/NPN sensor or push-pull input, Relay contact output, DIP switch selectable functions, Minimum/maximum control, Up to SIL 2 acc. to IEC 61508
  
Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
 
KFA6-SR-2.3L.FA
Switch Amplifier
2-channel, 115/230 V AC supply, 3-wire PNP/NPN sensor or push-pull input, Relay contact output, DIP switch selectable functions, Minimum/maximum control, Up to SIL 2 acc. to IEC 61508
 
Switch Amplifier
1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511KFA6-SR2-Ex1.W
 
KFA6-SR2-Ex1.W.LB
Switch Amplifier
1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
 
KFA6-SR2-Ex2.W
Switch Amplifier
2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
 
KFA6-SR2-Ex2.W.IR
Switch Amplifier
2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Latching relay contact output, Line fault detection (LFD)
 
Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
 
KFD2-SH-Ex1
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for approved dry contacts or SN/S1N sensors, Relay contact output, Fault indication output, Line fault detection (LFD), Up to SIL 3 acc. to IEC 61508, Up to PL d acc. to EN/ISO 13849
 
KFD2-SOT3-Ex1.LB
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
 
KFD2-SOT3-Ex1.LB.IO
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Isolated passive transistor output, non-polarized, Isolated passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
 
KFD2-SOT3-Ex2
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
 
KFD2-SOT3-Ex2.IO
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
 
Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
 
KFD2-SR2-Ex1.W
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
 
KFD2-SR2-Ex1.W.LB
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
 
KFD2-SR2-Ex2.W
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
 
KFD2-SR3-2.2S
Switch Amplifier
2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), 2 x 2 relay contact outputs with AND logic, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
 
KFD2-SR3-Ex2.2S
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), 2 x 2 relay contact outputs with AND logic, Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
  
Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
 
KFD2-SRA-Ex4
Switch Amplifier
4-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 50 % less wiring, 2:1 technology, Relay contact output, Line fault detection (LFD), Reversible mode of operation
 
KFD2-ST3-Ex1.LB
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
 
KFD2-ST3-Ex2
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Active transistor output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
 
KFU8-SR-1.3L.V
Switch Amplifier, Timer Relay
1-channel signal conditioner, Universal usage at different power supplies, 3-wire PNP/NPN sensor or push-pull input, 2 relay contact outputs, Adjustable energized/de-energized delay
 
KHA6-SH-Ex1
Switch Amplifier
1-channel isolated barrier, 115/230 V AC supply, Input for approved dry contacts or SN/S1N sensors, Relay contact output, Fault indication output, Line fault detection (LFD), Up to SIL 3 acc. to IEC 61508, Up to PL d acc. to EN/ISO 13849
 
HiD2824
Switch Amplifier
4-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, 4 relay contact outputs, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
 
HiD2844
Switch Amplifier
4-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, 4 passive transistor outputs, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
 
KCD2-SR-1.LB
Switch Amplifier
1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
KCD2-SR-2
Switch Amplifier
2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
KCD2-SR-Ex1.LB
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
  
Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
 
KCD2-SR-Ex2
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
HiC2831
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR input, Usable as signal splitter (1 input and 2 outputs), 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), SIL 2 (SC 3) acc. to IEC/EN 61508
 
HiC2831R1
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, Application-specific outputs, Usable as signal splitter (1 input and 2 outputs), 2 passive transistor outputs (resistive), Line fault transparency (LFT), SIL 2 (SC 3) acc. to IEC/EN 61508
 
HiC2831R2
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, Application-specific outputs, Usable as signal splitter (1 input and 2 outputs), 2 passive transistor outputs (resistive), Line fault transparency (LFT), SIL 2 (SC 3) acc. to IEC/EN 61508
 
HiC2832R1
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, Application-specific outputs, 2 passive transistor outputs (resistive), Line fault transparency (LFT), SIL 2 (SC 3) acc. to IEC/EN 61508
 
HiC2841
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR input, Usable as signal splitter (1 input and 2 outputs), 2 passive transistor outputs, Line fault detection (LFD), Reversible mode of operation, SIL 2 (SC 3) acc. to IEC/EN 61508
 
HiC2842
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, 2 passive transistor outputs, Line fault detection (LFD), Reversible mode of operation, SIL 2 (SC 3) acc. to IEC/EN 61508
 
HiC2853
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (bus powered), Input for approved dry contacts or SN/S1N sensors, Active voltage output, Passive transistor output (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Up to SIL 3 acc. to IEC 61508
 
HiC2853R1
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (bus powered), Input for approved dry contacts or SN/S1N sensors, Active voltage output, Passive transistor output (resistive), Line fault transparency (LFT), Up to SIL 3 acc. to IEC 61508
 
KCD2-SON-Ex1
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
  
Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
 
KCD2-SOT-1.LB
Switch Amplifier
1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
KCD2-SOT-Ex1.LB
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
KCD2-SOT-Ex2
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
KCD2-SOT-Ex2.SP
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
 
KCD2-ST-Ex1.LB
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 active transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
KCD2-ST-Ex2
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
KFA5-SR2-Ex1.W
Switch Amplifier
1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
 
KFA5-SR2-Ex1.W.LB
Switch Amplifier
1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
 
KFA5-SR2-Ex2.W
Switch Amplifier
2-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
 
KFD2-DU-Ex1.D
Switch Amplifier, Timer Relay
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact and transistor output, Adjustable output timer functions from 10 ms ... 60 min, Input frequency up to 80 Hz; pulse divider up to 1 kHz, Reset function, Configurable by keypad, Line fault detection (LFD)
 
Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
 
KFD2-SH-Ex1.T.OP
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for approved dry contacts or SN/S1N sensors, Active voltage output, Relay contact output, Fault indication output, Line fault detection (LFD), Up to SIL 3 acc. to IEC 61508, Up to PL d acc. to EN/ISO 13849
 
S1SD-1DI-1R
Switch Amplifier
1-channel signal conditioner, 24 V DC supply, Input for 2- or 3-wire sensors or AC/DC voltage sources, Relay contact output, Timer function, Configurable by DIP switches, Connection via screw terminals
WE 77/Ex-1 115V
Switch Amplifier
1-channel, Control circuit EEx ia IIC, 115 V AC supply voltage, Reversible mode of operation, Lead breakage (LB) monitoring, 1 relay contact output (change-over contact)
 
WE 77/Ex-1 230V
Switch Amplifier
1-channel, Control circuit EEx ia IIC, 230 V AC supply voltage, Reversible mode of operation, Lead breakage (LB) monitoring, 1 relay contact output (change-over contact)
WE 77/Ex-2 115V
Switch Amplifier
2-channel, Control circuit EEx ia IIC, 115 V AC supply voltage, Reversible mode of operation, Lead breakage (LB) monitoring, 1 relay contact output (change-over contact) per channel
WE 77/Ex-2 230V
Switch Amplifier
2-channel, Control circuit EEx ia IIC, 230 V AC supply voltage, Reversible mode of operation, Lead breakage (LB) monitoring, 1 relay contact output (change-over contact) per channel
 
HiC2831R3
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, Application-specific outputs, Usable as signal splitter (1 input and 2 outputs), 2 passive transistor outputs (resistive), Line fault transparency (LFT), SIL 2 (SC 3) acc. to IEC/EN 61508
 
HiC2832
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), SIL 2 (SC 3) acc. to IEC/EN 61508
 
HiC2832R2
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, Application-specific outputs, 2 passive transistor outputs (resistive), Line fault transparency (LFT), SIL 2 (SC 3) acc. to IEC/EN 61508
 
HiC2832R3
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, Application-specific outputs, 2 passive transistor outputs (resistive), Line fault transparency (LFT), Up to SIL 2 acc. to IEC 61508
  
Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
 
HiC2851
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (bus powered), Input for approved dry contacts or SN/S1N sensors, Active voltage output, Passive transistor output (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Up to SIL 3 acc. to IEC 61508
 
HiC2853R2
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (bus powered), Input for approved dry contacts or SN/S1N sensors, Application-specific outputs, Active voltage output, Passive transistor output (resistive), Line fault transparency (LFT), Up to SIL 3 acc. to IEC 61508
 
KCD2-SON-Ex1.R1
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs (resistive), Application-specific outputs, Line fault transparency (LFT), Usable as signal splitter (1 input and 2 outputs), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
KCD2-SON-Ex1.R2
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, Application-specific outputs, Usable as signal splitter (1 input and 2 outputs), 2 passive transistor outputs (resistive), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
KCD2-SON-Ex1.R3
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, Application-specific outputs, Usable as signal splitter (1 input and 2 outputs), 2 passive transistor outputs (resistive), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
KCD2-SON-Ex1.SP
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
 
KCD2-SON-Ex2
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
KCD2-SON-Ex2.R1
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs (resistive), Application-specific outputs, Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
KCD2-SON-Ex2.R2
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Application-specific outputs, 2 passive transistor outputs (resistive), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
KCD2-SON-Ex2.R3
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Application-specific outputs, 2 passive transistor outputs (resistive), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
 
KCD2-SON-Ex2.SP
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
 
KCD2-SOT-1.LB.SP
Switch Amplifier
1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
 
KCD2-SOT-2
Switch Amplifier
2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
KCD2-SOT-2.SP
Switch Amplifier
2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
 
KCD2-SOT-Ex1.LB.SP
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
 
KCD2-ST-1.LB
Switch Amplifier
1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 active transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
KCD2-ST-1.LB.SP
Switch Amplifier
1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 active transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
 
KCD2-ST-2
Switch Amplifier
2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
KCD2-ST-2.SP
Switch Amplifier
2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
 
KCD2-ST-Ex1.LB.SP
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 active transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
 
Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
 
KCD2-ST-Ex2.SP
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
 
KFA4-SR2-Ex2.W
Switch Amplifier
2-channel, Control circuit EEx ia IIC, Reversible mode of operation, 1 relay contact output (change-over contact) per channel, EMC acc. to NAMUR NE 21, LB/SC monitoring, Up to SIL 2 acc. to IEC 61508/IEC 61511
 
KFA5-DU-Ex1.D
Switch Amplifier, Timer Relay
1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact and transistor output, Adjustable output timer functions from 10 ms ... 60 min, Input frequency up to 80 Hz; pulse divider up to 1 kHz, Reset function, Configurable by keypad, Line fault detection (LFD)
 
KFA5-SOT2-Ex2
Switch Amplifier
2-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
 
KFA5-SR2-Ex2.W.IR
Switch Amplifier
2-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Latching relay contact output, Line fault detection (LFD)
 
KFD2-SOT3-Ex2.IO-Y1
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, TTL level, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
 
KFA4-SR2-Ex1.W
Switch Amplifier
1-channel, Control circuit EEx ia IIC, Reversible mode of operation, 1 relay contact output (change-over contact), EMC acc. to NAMUR NE 21, LB/SC monitoring, Up to SIL 2 acc. to IEC 61508/IEC 61511
 
KFA4-SR2-Ex1.W.LB
Switch Amplifier
1-channel, Control circuit EEx ia IIC, Reversible mode of operation, Output I: relay contact output (change-over contact), Output II: optionally signal output/fault signal, EMC acc. to NAMUR NE 21, LB/SC monitoring, Up to SIL 2 acc. to IEC 61508/IEC 61511
 
KFD2-SR2-2.2S
Switch Amplifier
2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), 2 x 2 relay contact outputs with AND logic, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
 
KFD2-SR2-Ex2.2S
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), 2 x 2 relay contact outputs with AND logic, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
 
Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
 
KFD2-SOT2-Ex2.IO-Y181008
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, TTL level, Line fault detection (LFD), Reversible mode of operation
 
KCD2-SR-Ex1.LB.SP
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
 
KCD2-SR-Ex2.SP
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
 
KFD2-SOT2-Ex1.LB
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
 
KFD2-SOT2-Ex1.LB.IO
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Isolated passive transistor output, non-polarized, Isolated passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
 
KFD2-SOT2-Ex2
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
 
KFD2-SOT2-Ex2.IO
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
 
KFD2-ST2-Ex1.LB
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Active transistor output, Active fault output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
 
KFD2-ST2-Ex2
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Active transistor output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
 
KCD2-SR-1.LB.SP
Switch Amplifier
1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
 
KCD2-SR-2.SP
Switch Amplifier
2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
 

 


Ordering Codes of Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
 
KFA6-SR2-Ex1.W.LB KFA6-SR2-Ex2.W.IR KFD2-DU-Ex1.D KFD2-ER-Ex1.W.LB KFD2-SH-Ex1.T KFD2-SH-Ex1.T.OP KFD2-SOT2-Ex1.N 
KFD2-SOT2-Ex2.IO KFD2-SOT2-Ex2.IO-Y181008 KFD2-SR2-Ex2.2S KFD2-SRA-Ex4 KFD2-ST2-Ex1.LB KHA6-SH-Ex1 KCD2-SON-Ex1 
KCD2-SON-Ex1.R1 KCD2-SON-Ex1.SP KCD2-SON-Ex2 KCD2-SON-Ex2.R1 KCD2-SON-Ex2.SP KCD2-SOT-Ex1.LB.SP KCD2-SOT-Ex2.SP 
KCD2-SR-Ex1.LB.SP KCD2-ST-Ex1.LB.SP KCD2-ST-Ex2 KCD2-ST-Ex2.SP KFA5-DU-Ex1.D KFD2-ELD-Ex16 KFD2-SOT2-Ex1.R1 KFD2
-UFC-Ex1.D KFU8-UFC-Ex1.D KFD2-DWB-Ex1.D KFA5-DWB-Ex1.D KFA6-DWB-Ex1.D KFD2-SR2-Ex2.W-SM KFD2-UFT-Ex2.D KFU8-
UFT-Ex2.D KFD2-RO-Ex2 KCD0-SD-Ex1.1245 KFD0-SD2-Ex1.1045 KFD2-SL2-Ex1 KFD2-SL2-Ex1.B KFD2-SL2-Ex1.LK KFD2-SL2-
Ex2.B KFD0-SD2-Ex2.1045 KFD2-SL2-Ex2 KFD2-VM-Ex1.35.L KFD0-SD2-Ex1.10100 KFD0-SD2-Ex1.1065 KFD0-SD2-Ex1.1180 

KFD0-SD2-Ex2.1245 KFD2-RCI-Ex1 KFD2-SL2-Ex1.LK.1045 KFD2-SL2-Ex1.LK.1270 KFD2-SL2-Ex1.LK-Y1 KCD0-SD-Ex1.1245.SP

 

Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived

 

KCD2-UT2-Ex1 KFD2-GUT-Ex1.D KFD2-UT2-Ex1 KFD2-UT2-Ex2 KFD0-CC-Ex1 KFD0-TR-Ex1 KFD0-TT-Ex1 KFD2-PT2-Ex2 KFD2-PT2-
Ex1-1 KFD2-PT2-Ex1-4 KFD2-PT2-Ex1-5 KFD2-PT2-Ex1-6-Y112844 KFD2-UT2-Ex1-1 KFD2-UT2-Ex2-1 KFD2-WAC2-Ex1.D KFU8-
GUT-Ex1.d KFD2-PT2-Ex1-Y98312 KFD2-WAC2-Ex1.D-Y1 KFD2-CRG2-Ex1.D KFD2-GUT-Ex1.D KFD2-GU-Ex1 KFD2-WAC2-Ex1.D KFU8
-CRG2-Ex1.D KFU8-GUT-Ex1.D KFD2-WAC2-Ex1.D-Y1 KCD2-SCD-Ex1 KFD2-SCD-Ex1.LK KFD2-SCD2-Ex1.LK KFD0-CS-Ex1.51P KFD2
-SCD2-Ex2.LK KFD2-CD-Ex1.32 KCD2-SCD-Ex1.HC KCD2-SCD-Ex1.SP KFD0-CS-Ex1.50P KFD0-CS-Ex1.53 KFD0-CS-Ex2.50P KFD0-
CS-Ex2.51P KFD2-CD2-Ex1 KFD2-CD2-Ex2 KFD2-SCD2-Ex1-Y1 KFD2-SCD2-Ex2-Y1 KCD2-SCD-Ex1.HC.SP KFD0-CS-Ex2.53 KFD0-
CS-Ex2.51P-Y107439 KCD2-STC-Ex1 KFD2-CRG2-Ex1.D KFD2-STC4-Ex1 KFD2-STC4-Ex1-Y1 KFD2-STC4-Ex1.2O KFD2-STC4-Ex2 
KFD2-STC4-Ex1.2O-Y1 KFD2-STC4-Ex1.H KCD2-STC-Ex1.2O KCD2-STC-Ex1.2O.DE KCD2-STC-Ex1.ES KCD2-STC-Ex1.HC KCD2-STC-
Ex1.SP KFD2-HLC-Ex1.D KFD2-HLC-Ex1.D.4S KFD2-STC3-Ex1 KFD2-STC4-Ex1.2O.H KFD2-STC4-Ex1.ES KFD2-STC4-Ex2-Y229428 
KFD2-STV3-Ex1-1 KFD2-STV3-Ex1-2 KFD2-STV4-Ex1-1 KFD2-STV4-Ex1-2 KFD2-STV4-Ex1.2O-1 KFU8-CRG2-Ex1.D KCD2-STC-
Ex1.ES.SP KCD2-STC-Ex1.HC.SP KFD2-HLC-Ex1.D.2W KFD2-STV4-Ex1.2O-2 KFD2-STV4-Ex2-1 KFD2-STV4-Ex2-2

 

Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived

 

KFD2-VR4-Ex1.26 KFD0-CS-Ex1.51P KFD0-SCS-Ex1.55 KCD2-RR-Ex1-Y1 KFD2-VR2-Ex1.50M KFD0-CS-Ex1.50P KFD0-CS-Ex1.52 
KFD0-CS-Ex1.53 KFD0-CS-Ex1.54 KFD0-CS-Ex2.50P KFD0-CS-Ex2.51P KFD0-CS-Ex2.52 KFD0-CS-Ex2.54 KFD2-FF-Ex2.RS232 
KFD2-VR-Ex1.12 KFD2-VR-Ex1.18 KFD2-VR-Ex1.19 KFD2-VR-Ex1.19-Y109129 KFD2-VR2-Ex1.500M KCD2-RR-Ex1 KCD2-RR-Ex1.SP 
KFD0-CS-Ex1.54-Y2 KFD0-CS-Ex2.53 KFD0-CS-Ex2.51P-Y107439

 

Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived

 

M-LB-2.275TN.D M-LB-2.275TT.D M-LB-1.275.D M-LB-2.150TN.D M-LB-2.255.T3.D M-LB-2.30.T3.D M-LB-3.275TNC.D M-LB-4.275TNS.D 
M-LB-4.275TT.D M-LB-1.150.D M-LB-1.150.M M-LB-1.275.M M-LB-1.NPE.M M-LB-2.150.T3.D M-LB-2.150.T3.M M-LB-2.255.T3.M M-LB-
2.30.T3.M M-LB-3.150TNC.D M-LB-4.150TNS.D P-LB-1.B.12 P-LB-1.C.123 P-LB-1.A.13 P-LB-1.D.1234 P-LB-2.A.1346 P-LB-2.B.1245 P-
LB-2.D.123456 P-LB-1.E.23 P-LB-1.F.1236 P-LB-2.C.2356 K-LB-1.30 K-LB-1.30G K-LB-1.6G K-LB-2.30 K-LB-2.3G K-LB-2.6 K-LB-2.6G 

K-LB-1.6 FN-LB-I FP-LB-I FS-LB-I

 

Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived

 

KFD2-SOT2-EX1.LB KFD2-SOT2-EX1.LB KFD2-SOT2-EX1.LB KFD2-SOT2-EX1.LB KFD2-SOT2-EX1.LB KFD2-STC4-EX1.H KFD2-UFT-EX2.D KFD2-STC4-EX1.2O-Y122582 KFD2-STC4-EX1-Y122583 KFD2-SH-EX1 KHA6-SH-EX1 KFD2-STC4-1 KFD2-STC4-1.20 KFD2-STC4-EX1 KFD2-STC4-EX1.H KFD2-STC3-EX1 KFD2-GUT-EX1.D K-CJC-BU KFA6-SR2-EX1.W.LB KFU8-FSSP-1.D KFD2-PT2-EX1 KFD2-PT2-EX1-5 K-ADP-USB KFD2-CRG2-EX1.D KFD2-CRG2-1.D UPR-03 UPR-05 KFD2-STC1-EX1 KFD2-WAC2-EX1.D KFD2-EB2.R4A.B KFD2-SOT2-EX2 KFD2-SOT2-EX1.LB KFD2-SL2-EX1 KFD2-SL2-EX2 KFD2-UT2-1 KFD2-UT2-2 KFD2-UT2-EX1 KFD2-UT2-EX2 WE77/EX2 WE77/EX1 WE77/EX1-BI KFD2-ST2-EX2 KFD2-ST2-EX1.LB KFD0-CS-EX2.51P KFD2-VD-EX1.1560 KFD2-VR4-EX1.26 HIC2025 HIC2031 KFA5-SR2-EX2.W KFA6-SR2-EX2.W KFD2-GUT-EX1.D KFD2-GUT-1.D KFD2-STC4-Ex2 KFD2-DWB-1.D KFU8-DWB-1.D KFA6-DWB-EX1.D KFD2-VR2-Ex1.50M KFD0-CS-EX1.54 KFD0-CS-EX2.54 KCD2-SR-EX2 KFD2-STC4-2 KFD2-ST-EX2 KFD0-SD-EX1.1065 KHD2-FF-EX2.P-RS232 KFD2-EB2 KFD2-CR4-1 KFD2-CR4-1.20 KFD2-RR-EX1 KFD2-SOT2-EX1.LB KFD2-STV4-EX1-1 KCD2-STC-EX1 KFD2-ST2-EX1.LB KFD2-CRG2-1.D KFD0-SD2-EX1.1045 KCD2-E KCD2-E2 KCD2-RR-EX1 KFD2-STV1-EX1-1 KFD0-RO-EX2 KCD2-SCD-1 KFD0-TR-EX1 KCD2-SR-EX1.LB KCD0-SD-EX1.1245 KFD0-RSH-1 KFD2-CD2-EX1 KFD2-CD2-EX2 KFD0-RSH-1-Y2 KFD2-CD-EX1.32-8 KCD0-SD-EX1.1245 Z954 Z728 Z787 Z787.H Z715 Z788 Z966 Z966.H Z964 Z728 Z728.H

 

Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived

 

HD2-FBPS-1.25.360 ELS-1 HCD2-FBPS-1.500 HD2-DM-A HD2-GTR-4PA KT-MB-GT2AD.FF KT-MB-GT2AD.FF.IO R-SP-E12 HCD2-FBPS-1.23.500 EI-0D2-10Y-10B FDH-1 HD2-DM-A.RO HD2-DM-B KFD2-BR-1.PA.1500 KFD2-BR-Ex1.3PA.93 KLD0-SAA KLD2-FBPS-1.25.360 KLD2-PR-1.IEC KT-MB-DMA KT-SRT-FF KT-SRT-PA USB-FBPS-1.11.45.NI BP-FBPS-1.30.1 FBTA-228-BPFB-R-8R HD2-GTR-4PA.PN KLD2-FBPS-1.12.220 FBTA-228-BPFB-8 FBTA-228-BPFB-R-4R HD2-FBPS-1.17.500 HD2-FBPS-1.23.500 HD2-FBPS-1.25.360 HD2-FBPS-1.500 KLD2-PR-Ex1.IEC KLD2-PR-Ex1.IEC1 MB-FB-4R.HO.SC EI-0D2-10Y-10B-Y1 DP-LBF-I1.36. F*-FT-Ex1 F*-FT-Ex1.D.IEC F*-FT-Ex1.I.IEC F*-LBF-D1.32 F*-LBF-I1.32 F.FB0.P**.A**.1.0.***.***.**** F.FB0.S**.A**.1.0.***.***.**** F.FB1.P14.A**.1.*.***.***.**** MBHC-FB-8R.HSC MBHC-FB-8R.RH MBHC-FB-8R.YO R2-SP-IC R4D0-FB-IA R8D0-MIO-Ex12.FF R8D0-MIO-Ex12.PA RD0-FB-Ex4. RD0-TI-Ex8.FF. RD0-TI-Ex8.PA. SCP-LBF-IA1.36.IE

 

Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived

 

HID2025 HID2026 HID2061 HID2061 HID2062 HID2062 HID2071 HID2071 HID2072 HID2072 HID2033 HID2034 HID2031 HID2032 HID2037 

HID2038 HID2029 HID2029 HID2030 HID2030 HID2029SK HID2030SK HID2035 HID2036 HID2000 HID2038Y HID2012 HID2038 HID2024 HID2096 HID2025 HID2026 HID2025SK HID2026SK HIC2095 HIC2065 HIC2027 HIC2068 HIC2077 HIC2000 HIC2025ES HIC2031HC HIC2025HC HID2025ES HIC2027DE HID2081 HID2082 H-CJC-SP-8 H-CJC-SC-8 HIC2031 HIC2025 HID2026 HIC2077-Y1 HIC2441 H-CJC-PT100 HIC2025 HIC2031 HIC2027 HIC2027DE HIC2081 HID2025ES HIC2025ES

 

Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived

 

KCD2-SCD-1   KCD2-SCD-EX1  KCD2-SR-EX1.LB    KCD2-SR-EX2   KCD2-STC-1   KCD2-STC-EX1   KCD2-STC-EX1.2O  KCD2-UT2-EX1
KFA6-SR2-Ex1.W  KFD0-SD2-Ex1.1045  KFD2-CD2-EX1  KFD2-CRG2-EX1.D  KFD2-DWB-1.D  KFD2-EB2   KFD2-GU-1   KFD2-GUT-Ex1.D
KFD2-SCD2-EX2.LK KFD2-SH-EX1.T.OP KFD2-SOT2-Ex2  KFD2-SR2-Ex1.W.LB  KFD2-SR2-Ex2.W  KFD2-ST2-Ex2  KFD2-STC4-1 
KFD2-STC4-EX2 KFD2-STC4-Ex2 KFD2-UT2-1 KFD2-UT2-2 KFD2-UT2-EX1  KFD2-UT2-Ex2 KFD2-VR4-EX1.26 KFD2-SR2-Ex2.W
KFD2-SL2-Ex1 KFD2-SR2-Ex1.W KFD2-STC4-Ex1 KFD2-SR2-EX.1.W.LB  KFD2-EB2.R4A.B KFD2-SCD2-EX1.LK KFD2-SR2-EX2.W
KFD2-SL2-EX2.B  KFD0-TT-EX1  KFD0-TR-EX1  KFD2-STC4-EX2  KFD2-UFC-EX1.D  KFD2-SCD2-EX2-LK  KFD2-CD-EX1.32-15
KFD2-STC4-EX1.2O KFD2-SH-EX1.T.OP KFD2-SR2-EX2.2S  KFD2-BR-1.PA.93 KFD2-UT2-EX2 KFD2-UFC-EX1.D KFD0-SD2-EX1.1045
KFD2-SOT2-EX1.LB KFD2-STC4-EX1.20  KFD2-STC4-1.20 KFD2-SCD2-EX2.LK KFD2-SCD2-2.LK KFD2-SH-EX1 KFD0-SD2-Ex2.1245

 

Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived

 

KFD2-SL2-Ex1.LK KFD2-BR-Ex1.3PA.93 KFD2-CD2-EX2 KFD2-UT2-EX2 KFD2-STC4-EX1.2O KFD2-CR4-1.2O KFD2-CD2-EX1 KFD2-SL2-EX2 KFD2-PR-1.IEC KFD2-WAC2-EX1.D KFD2-UFT-EX2.D KFD2-UFC-1.D KFD-STC4-EX1.2O.DE KFD2-SCD2-EX1 KFD2-PT2-Ex1 KFD2-SR2-EX2.2S KFD0-SD2-EX1.1045 KCD2-E2L KCD2-STC-EX1 KFD2-SR2-EX1.W KFD2-SCD2-EX1-LK KCD2-SCD-EX1 KFD2-UT2-EX1 KFD2-VR4-EX1.26 KFD2-SR2-EX1.W.LB KFDO-RSH-1 KFD2-GS-1.2W KFD2-EB.R4A.B KFD0-SCS-EX1.55 KFD2-EX1.32 KFD2-STC4-Ex1-Y1. KFD2-SR2-EX2.2S KFD2-SCD2-EX2.LK KCD2-SCD-1 KCD2-SCD-EX1 KCD2-SR-EX1.LB KCD2-SR-EX2 KCD2-STC-1 KCD2-STC-EX1 KCD2-STC-EX1.2O KCD2-UT2-EX1 KFA6-SR2-Ex1.W KFD0-SD2-Ex1.1045 KFD2-CD2-EX1 KFD2-CRG2-EX1.D KFD2-DWB-1.D KFD2-EB2 KFD2-GU-1 KFD2-GUT-Ex1.D KFD2-SCD2-EX2.LK KFD2-SH-EX1.T.OP KFD2-SOT2-Ex2 KFD2-SR2-Ex1.W.LB  KFD2-SR2-Ex2.W KFD2-ST2-Ex2 KFD2-STC4-1 KFD2-STC4-EX2 KFD2-STC4-Ex2 KFD2-UT2-1 KFD2-UT2-2 KFD2-UT2-EX1 KFD2-UT2-Ex2 KFD2-VR4-EX1.26

 

Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived

 

KCD2-STC-Ex1 KCD2-STC-Ex1.ES KFD2-CRG2-Ex1.D KFD2-HLC-Ex1.D KFD2-HLC-Ex1.D.2W KFD2-STC4-Ex1 KFD2-STC4-Ex1.2O KFD2-STC4-Ex1.2O.H KFD2-STC4-Ex1.H KFD2-STC4-Ex2 KFU8-CRG2-Ex1.D KCD2-STC-Ex1.2O KCD2-STC-Ex1.2O.ES KCD2-STC-Ex1.ES.SP KCD2-STC-Ex1.SP KFD2-STC3-Ex1 KFD2-STC4-Ex1-Y1 KFD2-STC4-Ex1.2O-Y1 KFD2-STC4-Ex1.ES KFD2-STC4-Ex2-Y1 KFD2-STC5-Ex1 KFD2-STC5-Ex1.2O KFD2-STC5-Ex1.2O.H KFD2-STC5-Ex1.H KFD2-STC5-Ex2 KFD2-STC5-Ex2 KFD2-STC5-Ex2 KFD2-STV4-Ex1.2O-1 KFD2-STV4-Ex2-1 KFD2-STV4-Ex2-2 KFD2-STV5-Ex1-1 KCD2-STC-Ex1.2O.DE KFD2-HLC-Ex1.D.4S KFD2-STV4-Ex1.2O-2 KCD2-STC-Ex1.HC KCD2-STC-Ex1.HC.SP KFD2-STC4-Ex1 KFD2-STC4-Ex1-Y1 KFD2-STC4-Ex1.2O KFD2-STC4-Ex1.2O-Y1 KFD2-STC4-Ex1.2O.H KFD2-STC4-Ex1.H KFD2-STV4-Ex1-1 KFD2-STV4-Ex1-2 KFD2-STV4-Ex1.2O-1 KFD2-STV4-Ex2-1 KFD2-STV4-Ex2-2 KFD2-STV4-Ex1.2O-2 KFD2-STC3-Ex1 KCD2-STC-Ex1-Y1

 

Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived

 

KCD2-STC-Ex1 KCD2-STC-Ex1.ES KFD2-CRG2-Ex1.D KFD2-HLC-Ex1.D KFD2-HLC-Ex1.D.2W KFD2-STC4-Ex1 KFD2-STC4-Ex1.2O KFD2-STC4-Ex1.2O.H KFD2-STC4-Ex1.H KFD2-STC4-Ex2 KFU8-CRG2-Ex1.D KCD2-STC-Ex1.2O KCD2-STC-Ex1.2O.ES KCD2-STC-Ex1.ES.SP KCD2-STC-Ex1.SP KFD2-STC3-Ex1 KFD2-STC4-Ex1-Y1 KFD2-STC4-Ex1.2O-Y1 KFD2-STC4-Ex1.ES KFD2-STC4-Ex2-Y1 KFD2-STC5-Ex1 KFD2-STC5-Ex1.2O KFD2-STC5-Ex1.2O.H KFD2-STC5-Ex1.H KFD2-STC5-Ex2 KFD2-STC5-Ex2 KFD2-STC5-Ex2 KFD2-STV4-Ex1.2O-1 KFD2-STV4-Ex2-1 KFD2-STV4-Ex2-2 KFD2-STV5-Ex1-1 KCD2-STC-Ex1.2O.DE KFD2-HLC-Ex1.D.4S KFD2-STV4-Ex1.2O-2 KCD2-STC-Ex1.HC KCD2-STC-Ex1.HC.SP KFD2-STC4-Ex1 KFD2-STC4-Ex1-Y1 KFD2-STC4-Ex1.2O KFD2-STC4-Ex1.2O-Y1 KFD2-STC4-Ex1.2O.H KFD2-STC4-Ex1.H KFD2-STV4-Ex1-1 KFD2-STV4-Ex1-2 KFD2-STV4-Ex1.2O-1 KFD2-STV4-Ex2-1 KFD2-STV4-Ex2-2 KFD2-STV4-Ex1.2O-2 KFD2-STC3-Ex1 KCD2-STC-Ex1-Y1

 

Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived

 

KCD2-SCD-1 KCD2-SCD-EX1 KCD2-SR-EX1.LB KCD2-SR-EX2 KCD2-STC-1 KCD2-STC-EX1 KCD2-STC-EX1.2O KCD2-UT2-EX1 KFA6-SR2-Ex1.W KFD0-SD2-Ex1.1045 KFD2-CD2-EX1 KFD2-CRG2-EX1.D KFD2-DWB-1.D KFD2-EB2 KFD2-GU-1 KFD2-GUT-Ex1.D KFD2-SCD2-EX2.LK KFD2-SH-EX1.T.OP KFD2-SOT2-Ex2 KFD2-SR2-Ex1.W.LB KFD2-SR2-Ex2.W KFD2-ST2-Ex2 KFD2-STC4-1 KFD2-STC4-EX2 KFD2-STC4-Ex2 KFD2-UT2-1 KFD2-UT2-2 KFD2-UT2-EX1 KFD2-UT2-Ex2 KFD2-VR4-EX1.26 KFU8-FSSP-1.D KCD2-SR-Ex1.LB KCD2-SR-Ex2 KFA6-DU-Ex1.D KFA6-ER-Ex1.W.LB KFA6-SOT2-Ex2 KFA6-SR2-Ex1.W KFA6-SR2-Ex1.W.LB KFA6-SR2-Ex2.W 

 

Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived
 

KFA6-SR2-Ex2.W.IR KFD2-DU-Ex1.D KFD2-ELD-Ex16 KFD2-ER-Ex1.W.LB KFD2-SH-Ex1 KFD2-SH-Ex1.T.OP KFD2-SOT3-Ex1.LB KFD2-SOT3-Ex1.LB.IO KFD2-SOT3-Ex2 KFD2-SOT3-Ex2.IO KFD2-SR2-Ex1.W KFD2-SR2-Ex1.W.LB KFD2-SR2-Ex2.W KFD2-SR3-Ex2.2S KFD2-SRA-Ex4 KFD2-ST3-Ex1.LB KFD2-ST3-Ex2 KHA6-SH-Ex1 KCD2-SON-Ex1 KCD2-SOT-Ex1.LB KCD2-SOT-Ex2 KCD2-SOT-Ex2.SP

 

Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived

 

KCD2-SR-Ex1.LB.SP KCD2-SR-Ex2.SP KCD2-ST-Ex1.LB KCD2-ST-Ex2 KFA5-SOT2-Ex2 KFA5-SR2-Ex1.W KFA5-SR2-Ex1.W.LB KFA5-SR2-Ex2.W KFA5-SR2-Ex2.W.IR KFD2-SH-Ex1.T KFD2-SOT3-Ex2.IO-Y1 KCD2-SON-Ex1.R1  KCD2-SON-Ex1.SP KCD2-SON-Ex2 KCD2-SON-Ex2.R1 KCD2-SON-Ex2.SP KCD2-SOT-Ex1.LB.SP KCD2-ST-Ex1.LB.SP KCD2-ST-Ex2.SP KFA4-SR2-Ex2.W KFA5-DU-Ex1.D KFA4-SR2-Ex1.W KFA4-SR2-Ex1.W.LB KFD2-SOT2-Ex1.LB KFD2-SOT2-Ex1.LB.IO KFD2-SOT2-Ex2 KFD2-SOT2-Ex2.IO KFD2-SOT2-Ex2.IO-Y181008 KFD2-SR2-Ex2.2S KFD2-ST2-Ex1.LB KFD2-ST2-Ex2 KFD2-STC4-EX1 KFD2-SR2-EX1.W KFD2-SR2-EX2.W KFD2-CD-EX1.32 KFD2-UT2-EX1. KFD2-ST-EX1 KFD2-UFC-EX1.D KFA5-SR2-EX2.W KFA5-SR2-EX1.W KFA6-SR2-EX2.W KFA5-SR2-EX1.W KFD2-ST-EX1 KFD2-SOT2-EX1 KFU8-UFC-EX1.D KFD2-CD-EX1.32 KFU8-FSSP-1.D KFA6-DWB-EX1.D 

 

Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived

 

KFD2-DWB-EX1.D KFA5-SR2-EX1,W KFA5-SR2-EX2,W KFD2-VR4-EX1.26 KFD2-STC4-EX1.20 KFD2-SOT2-EX2 KFD2-ST2-EX1.B KFD2-DWB-EX1.D KFD2-UFC-EX1.D KFA6-STR-1.24.500 KFD2-UT2-1 KFD2-UT2-2 KFD2-CD-1.32 KFD2-SOT2-EX1.LB KFA6-SR2-EX1.LB KFA6-SOT2-EX2 KFU8-FSSP-1.D KFU8-UFC-EX1,D KFU8-UFT-EX2.D KFA6-DWB-EX1.D KFD0-SCS-EX1.55 KFD2-STC4-EX2 KFD2-STC4-EX1Y125882 KFD2-UT2-EX2 UPR-03 KFD2-EB2.B4.AB KFD2-CD-EX1.32 KFD2-STC4-EX1 KFD2-UT2-EX1 KFD2-SR2-Ex1.W KFD2-SCD-EX1.LK KFD2-SOT2-EX2 KFD2-STC4-EX2 KFD2-SR2-Ex2.W KFD2-SR2-Ex1.W KFD2-STC4-EX1.2O KFD0-SCS-EX1.55 KFU8-UFC-EX1.D KFD2-SOT2-EX2 KFD2-STC4-EX1 KFD2-UT2-EX2 KFD2-VR4-EX1.26 KFD2-EB2.R4A.B KFD2-BR-1.PA.93 KFU8-DWB-1.D KFU8-DW-1.D KFU8-UFT-EX2.D Z787.H UPR-03

 

Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived

 

KCD2-SR-EX1.LB KFD2-SR2.Ex1.W KFA5-SR2-Ex1.W KFA6-SR2-Ex1.W KFD2-SR2-Ex1.W.LB KFA5-SR2-Ex1.W.LB KFA6-SR2-Ex1.W.LB KCD2-SR-EX2 KFD2-SR2-Ex2.W KFA5-SR2-Ex2.W KFA6-SR2-Ex2.W KFA5-SR2-EX2.W.IR KFA6-SR2-EX2.W.IR KFD2-SR2-Ex2.2S KFD2-SRA-Ex4 KFD2-SRT-Ex1 KFD2-SR-Ex1.4S.LK KFD2-DU-Ex1.D KFA5-DU-EX1.D KFA6-DU-EX1.D KFD2-ER-EX1.W.LB KFA5-ER-EX1.W.LB KFA6-ER-EX1.W.LB KFD2-ST2-Ex1.LB KFD2-ST2-Ex2 KFD2-SOT2-Ex1.LB KFD2-SOT2-EX1.LB.IO KFD2-SOT2-Ex1.N KFD2-SOT2-Ex2 KFA5-SOT2-Ex2 KFA6-SOT2-Ex2 KFD2-SOT2-Ex2.IO KFD2-SH-Ex1 KFD2-SH-Ex1.T.OP KHA6-SH-Ex1 KFD2-SR2-EX2.W.SM KFD2-DWB-Ex1.D KFA5-DWB-EX1.D KFA6-DWB-EX1.D KFD2-UFC-EX1.D KFU8-UFC-EX1.D KFD2-UFT-Ex2.D KFU8-UFT-Ex2.D KFD0-SD2-Ex1.1045 KFD0-SD2-Ex2.1045 KCD0-SD-EX1.1245 KFD0-SD2-EX2.1245 KFD0-SD2-Ex1.1065 KFD0-SD2-Ex1.1180 KFD0-SD2-Ex1.10100 KFD2-SL2-EX1 KFD2-SL2-EX1.B KFD2-SL2-Ex1.LK KFD2-SL2-Ex2 

 

Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived

 

KFD2-SL2-Ex2.B KFD2-VM-Ex1.35 KFD2-VM-Ex1.35.L KFD0-RO-Ex2 KCD2-STC-EX1 KFD2-STC4-Ex1 KFD2-STC4-Ex1-Y122583 KFD2-STC4-Ex1.H KFD2-STV4-EX1-1 KFD2-STV4-EX1-2 KFD2-STC4-Ex1.2O KFD2-STC4-Ex1.2O-Y122582 KFD2-STC4-Ex1.2O.H KFD2-STV4-EX1.2O-1 KFD2-STV4-Ex1.2O-2 KFD2-STC4-Ex2 KFD2-STC4-Ex2-Y203646 KFD2-STV4-EX2-1 KFD2-STV4-EX2-2 KFD2-STC3-Ex1 KFD2-STV3-Ex1-1 KFD2-STV3-Ex1-2 KFD2-CRG-Ex1.D KFU8-CRG-Ex1.D KFD0-CS-Ex1.52 KFD0-CS-Ex2.52 KFD0-CS-Ex1.54 KFD0-CS-Ex2.54 KFD2-VR2-Ex1.50m KFD2-VR-Ex1.500m KFD2-VR-Ex1.12 KFD2-VR-Ex1.18 KFD2-VR-Ex1.19 KFD2-VR4-EX1.26 KFD0-CC-Ex1 KFD2-WAC2-EX1.D KFD2-UT2-Ex1 KFD2-UT2-Ex1-1 KFD2-UT2-Ex2 KFD2-UT2-Ex2-1 KFD0-TR-Ex1 KFD0-TT-Ex1 KCD2-RR-Ex1 KFD2-GU-Ex1 KFD2-GUT-Ex1.D KFU8-GUT-EX1.D KFD2-UT2-Ex1 KFD2-UT2-Ex1-1 KFD2-UT2-Ex2 KFD2-UT2-Ex2-1 KFD2-RR-Ex1 KFD2-PT2-Ex1 KFD2-PT2-Ex1-1 KFD2-PT2-Ex1-4 KFD2-PT2-Ex1-5 KFD0-RC-Ex1 KFD2-HLC-EX1.D KFD2-HLC-EX1.D.2W KFD2-HLC-EX1.D.4S KFD2-FF-Ex2.RS232 KFD2-ELD-Ex16

 

Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived

 

KCD2-SCD-EX1 KFD2-SCD-Ex1.LK KFD2-SCD2-Ex1.LK KFD2-CD2-EX1 KFD2-CD-EX1.32 KFD2-SCD2-EX2.LK KFD2-CD2-EX2 KFD0-SCS-Ex1.55 KFD0-CS-Ex1.50P KFD0-CS-Ex1.51P KFD0-CS-Ex1.53 KFD0-CS-Ex2.50P KFD0-CS-Ex2.51P KFD0-CS-Ex2.53 KFD2-EB2.R4A.B KFD2-EB2 KFA6-STR-1.24.500 KFA6-STR-1.24.4 UPR-03 UPR-03-S UPR-05 UPR-05-S UPR-I UPR-E K-MS K-CJC-BU KF-FKC-3G2B KF-FKC-5B KF-FKC-5G K-500R0%1 KCD0-LGH KFD0-LGH KFD0-LGH-GN KFD0-LGH-Y34868 F-KD-Ex2 F-KDR-Ex2 IS01 F-MPN-1 K-ADP1 K-ADP-USB


 Pepperl-fuchs  Explosion Protection KFA6-SR2-EX1.W Part no103374 (1)_副本

Pepperl+Fuchs KFA6-SR2-Ex2.W Safety Barriers KFA6-SR2-Ex2.W Switch Amplifiers Arrived


Windy Wang
HONGKONG XIEYUAN TECH CO., LIMITED  
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com
Website:  http://www.hkxytech.com/   | GMT/UTC +8


Related Products