Pepperl fuchs HiD2824 Switch Amplifier With Good Price In Stock
Pepperl + Fuchs HiD2824 4-channel-channel isolated barrier is used for intrinsic safety applications. It transfers digital signals (NAMUR sensors/mechanical contacts) from a hazardous area to a safe area.
Brand: Pepperl + Fuchs
Place of origin: Singapore / Germany
1. General Introduction
Pepperl + Fuchs HiD2824 4-channel isolated barrier for ADV151 is used for intrinsic safety applications. It transfers digital signals (NAMUR sensors/mechanical contacts) from a hazardous area to a safe area. The proximity sensor or switch controls two form A normally open relay outputs for the safe area load. The module output changes state when the input signal changes state. The normal output state can be reversed withthe selector switches on the side of the unit. Line fault detection (LFD) can be selected or disabled via a selector switch. During an error condition, the relay reverts to its de-energized state and the LEDs indicate the fault. A separate fault output bus is available. The fault conditions can be monitored via a Fault Indication Board. This module mounts on a HiD Termination Board.
2. Features
• 4-channel isolated barrier
• 24 V DC supply (bus powered)
• Dry contact or NAMUR inputs
• 4 relay contact outputs
• Line fault detection (LFD)
• Up to SIL2 acc. to IEC 61508
3. General Specification for HiD2824
Technical data | HiD2824 |
Supply | |
Rated voltage | 20.4 ... 30 V DC via Termination Board |
Rated current | 15 mA at 24 V, relay energized (per channel) |
Power loss | 0.35 W at 24 V (per channel) |
Input | |
Rated values | acc. to EN 60947-5-6 (NAMUR) |
Connectable sensor types | potential free contact or proximity sensor |
Switching point | contact open 0.2 ... 1.2 mA, contact closed 2.1 ... 6.5 mA |
Line fault detection | breakage 0 ... 0.2 mA, short-circuit 6.5 mA ... maximum value |
Output | |
Output | signal: relay SPST per channel, phase selectable |
Response time | 20 ms |
Contact loading | 50 V DC/0.5 A non-inductive |
Mechanical life | 107 switching cycles |
Error message output | |
Output type | open collector transistor (internal fault bus) |
Transfer characteristics | |
Switching frequency | < 10 Hz |
Ambient conditions | |
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Mechanical specifications | |
Protection degree | IP20 |
Mass | approx. 100 g |
Dimensions | 12.5 x 128 x 106 mm (0.5 x 5.1 x 4.2 in) |
Data for application in connection with Ex-areas | |
EC-Type Examination Certificate | CESI 02 ATEX 086 |
Statement of conformity | PF 11 CERT 2109 X |
CSA approval | |
Control drawing | 366-005CS-12B (cCSAus) |
4. Selection tables
Termination Board & Barrier Module Selection table for Yokogawa CENTUM VP DCS system | ||||||
Yokogawa | Pepperl+Fuchs Termination Board | Pepperl+Fuchs Barrier Module | ||||
CENTUM VP | Channel | Class | Number of module | Type | Channel | Type |
Selection of Digital Input signals | ||||||
ADV151 | 32 | IS | 32 | HiCTB32-YC3-RRB-AK-CC-DX32 | 1 | HiC2821 |
ADV151 | 32 | IS | 36 | HiCTB16-YC3-RRB-AK-CC-DX32 | 2 | HiC2822 |
ADV151 | 32+ | IS | 40 | HiCTB08-YC3-RRB-AK-CC-DX32 | 4 | HiC2824 |
Selection of Digital Output signals | ||||||
ADV551 | 32 | IS | 32 | HiCTB32-YC3-RRB-AK-CC-DX32-Y1 | 1 | HiC2871 |
ADV551 | 32 | IS | 16 | HiCTB16-YC3-RRB-AK-CC-DX32 | 2 | HiD2872 HiD2876 |
Selection of Analog Input signals | ||||||
AAl143 | 16 | IS | 16 | HiCTB16-YC3-RRB-KS-CC-Al16 | 1 | HiC2025 |
AAl143 | 16 | IS | 8 | HiDTB08-YC3-RRB-KS-CC- Al16 | 2 | HiD2026 HiD2030 HiD2082 |
AAl143 | 16 | IS | 16 | HiCTB08-YC3-RRB-AK-CC- Al16 | 1 | HiD2081 |
AAl141 | 16 | IS | 16 | HiCTB16-YC3-RRB-KS-CC- Al16-Y1 | 1 | HiC2025 |
AAl141 | 16 | IS | 16 | HiCTB16-YC3-RRB-KS-CC- Al16-Y2 | 1 | HiC2025 |
AAl141 | 16 | IS | 8 | HiDTB08-YC3-RRB-KS-CC- Al16-Y1 | 2 | HiD2026 HiD2030 |
Selection of Analog Output signals | ||||||
AA1543 | 16 | IS | 16 | HiCTB16-YC3-RRB-KS-CC-AO16 | 1 | HiC2031 |
AA1543 | 16 | IS | 8 | HiCTB16-YC3-RRB-KS-CC-AO16 | 2 | Hid2038Y |
ADV151 | 32+ | IS | 40 | HiCTB08-YC3-RRB-AK-CC-DX32 | 4 | HiC2824 |
Selection of Analog Input and Output signals | ||||||
AAI841 | 16 | IS | 16 | HiCTB16-YC3-RRB-KS-CC-AM16 | 1 | HiC2025 HiC2031 |
AAI841 | 16 | IS | 8 | HiDTB08-YC3-RRB-KS-CC-AM16-Y1 | 2 | HiD2026 HiD2030 HiD2032 |
AAI135 AAI835 | 8 | IS | 8 | HiCTB08-YC3-RRB-KS-CC-AM08 | 1 | HiC2025 HiC2031 |
AAI841 | 16 | IS | 16 | HiCTB16-YC3-RRB-KS-CC-AM16-Y1 | 1 | HiC2025 HiC2031 |
AAI841 | 16 | IS | 8 | HiDTB08-YC3-RRB-KS-CC-AM16 | 2 | HiD2026 HiD2038Y |
5. Diagrams
Hot Tags: HiD2824, China, Pepperl+Fuchs, suppliers, price, quotation, contractor, revamping, engineering, upgrading, installation, commissioning, immigration, integrator, configuration, programming, barrier
HID2025 | HID2038 | HiC2842 |
HID2026 | HID2024 | HiC2851 |
HID2061 | HID2096 | HiC2853 |
HID2062 | HID2025SK | HiC2853R1 |
HID2071 | HID2026SK | HiC2853R2 |
HID2072 | HIC2095 | HiC2831R3 |
HID2033 | HIC2065 | HiC2832 |
HID2034 | HIC2027 | HiC2832R2 |
HID2031 | HIC2068 | HiC2832R3 |
HID2032 | HIC2077 | HiD2822 |
HID2037 | HIC2000 | HiC2025Y1 |
HID2029 | HIC2025ES | HiC2000 Blank |
HID2030 | HIC2031HC | HiD2000 Blank |
HID2029SK | HIC2025HC | HiC2877 |
HID2030SK | HID2025ES | HiD2876 |
HID2035 | HIC2027DE | HiC2871 |
HID2036 | HID2081 | HiC2873 |
HID2000 | HID2082 | HiC2873Y1 |
HID2038Y | H-CJC-SP-8 | HiC5861 |
HID2012 | H-CJC-SC-8 | HiC5861Y1 |
HiC2441 | HIC2077-Y1 | HiC5863 |
HiC2821 | HIC2441 | HiC5863Y1 |
HiC2822 | H-CJC-PT100 | HiC2025A |
HiD2824 | HIC2025 | HiD2022 |
HiD2844 | HIC2031 | HiD2022SK |
HiC2831 | HIC2081 | HiC2027ES |
HiC2831R1 | HiD2842 | HiC2832R1 |
HiC2831R2 | HiC2871A | HiC2841 |
HiD2872 | HiC2883 |
\
Windy Wang
HONGKONG XIEYUAN TECH CO., LIMITED
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com
Website: http://www.hkxytech.com/ | GMT/UTC +8