Pepperl+Fuchs Temperature Multi-Input Device for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 With Good Price In Stock
Product Features of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock
Temperature Multi-Input Device for Cabinet InstallationRD0-TI-Ex8.FF.*
< For 8 temperature or analog sensors
< Installation in Zone 1/Div. 1, intrinsically safe
< Sensors in Zone 0/Div. 1
< Connection to fieldbus acc. to FISCO or Entity
< For FOUNDATION Fieldbus H1
< PCS integration via device description and function blocks
< Concentrator method for simplified configuration
< Monitors sensor condition
< For T/C, RTD 2-, 3-, 4-wire, voltage and resistance
< Cold junction compensation
< Removable terminals
Product Function of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock
The Temperature Multi-Input (TM-I) for DIN rail installation connects up to 8 analog inputs to the DCS via fieldbus. It is installed in a typically prewired field enclosure close to the sensors in the hazardous area. The TM-I is certified intrinsically safe and as associated apparatus: inputs are intrinsically safe even when the fieldbus connection is not. Analog inputs can be resistance temperature sensors with 2, 3, and 4 wires, measuring sensors, thermocouples, or millivolt signals.
The TM-I communicates all data, configuration, and alarms via one fieldbus address and function blocks (8xAI or 1xMAI) to the DCS. For simplified configuration it supports the concentrator method: inputs can be configured all at once or individually. Fieldbus powers the sensors and the temperature interface itself, additional power or wiring is not required.
Cold junction compensation for thermocouples is integrated. The TM-I detects and reports lead breakage and short circuit conditions.
Technical Specification of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock
General specifications of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock
Design / Mounting Cabinet installation
Fieldbus interface of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock
Fieldbus type FOUNDATION Fieldbus
Physical layer profile profile type 511 (FISCO), profile type 111 (Entity)
ITK version 6.2.0 (DEV_REV 02)
1
Release
date:
2021-01-- 12 Date of
Release date: 2021-01-12 Date of issue: 2021-01-12 Filename: t158061_eng.pdf
Pepperl+Fuchs Group Germany: +49 621 776 2222
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
USA: +1 330 486 0002 Singapore: +65 6779 9091
www.pepperl-fuchs.com pa-info@us.pepperl-fuchs.com pa-info@de.pepperl-fuchs.com pa-info@sg.pepperl-fuchs.com
Technical Data
Implementation resource block1x RS
function block8x AI, 1x MAI
transducer block8x sensor TB, 1x concentrator TB
Execution time AI, MAI 40 ms max.
Macro cycle typical for one device 8xAI or 1xMAI max. 500 ms
Firmware update via separate plug connection
FDE (Fault Disconnect Equipment) 6.7 mA
Polarity not polarity sensitive
Rated voltage UN 9 ... 32 V
Rated current IN max. 23 mA
Indicators/operating means of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock
LED PWR green: on, bus voltage existent
LED COM ERR red, continuous lightning: hardware error; red, flashing: no bus activities or bus fault;
off: no error
LED CHANNEL ERROR red: 2 Hz flashing: lead breakage, overrange; off: no error
Input of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock
Number 8
Sensor types see table 1
Grounding grounding of thermoelements possible
Error detection lead breakage, wiring error, hardware device error
Common mode voltage Input to Input 600 Vpeak
Transfer characteristics of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock
Deviation
Cold junction compensation ± 0.5 °C (32.9 °F)
Resolution/accuracy see table 2
Influence of ambient temperature see table 3
Linearization T/C input 0.1°C RTD input 0.03°C
Internal measurement cycle for all sensor types max. 1 s
Galvanic isolation of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock
Fieldbus/inputs safe galvanic isolation acc. to EN 60079-11, voltage peak value 375 V
Directive conformity of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013
Standard conformity of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock
Galvanic isolation EN 60079-11
Electromagnetic compatibility NE 21:2011
Degree of protection IEC 60529
Fieldbus standard IEC 61158-2
Shock resistance EN 60068-2-27
Vibration resistance EN 60068-2-6
Ambient conditions of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock
Ambient temperature -40 ... 70 °C (-40 ... 158 °F) hazardous area
-40 ... 85 °C (-40 ... 185 °F) safe area
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Relative humidity ≤ 95 % non-condensing
Shock resistance 15 g , 11 ms
Vibration resistance 5 g , 10 ... 150 Hz
Corrosion resistance acc. to ISA-S71.04-1985, severity level G3
Mechanical specifications of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock
Connection type plug-in terminals , spring terminal and screw terminal
Core cross-section
Bus up to 2.5 mm2
Inputs up to 2.5 mm2
Housing material Polycarbonate
Degree of protection IP20
Mass 360 g
Mounting mounting on DIN rail in cabinet
Data for application in connection with hazardous areas of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock
EU-type examination certificate PTB 03 ATEX 2237
Marking 1 II 2 (1) G Ex ia [ia Ga] IIC T4 Gb , 1 II (1) G [Ex ia Ga] IIC , 1 II (1) D [Ex ia Da] IIIC
, 1 II 3 G Ex ic IIC T4 Gc
Bus FISCO see EC-Type Examination Certificate
Inputs see EC-Type Examination Certificate
Certificate PTB 03 ATEX 2238 X
Marking 1 II 3 G Ex nA IIC T4 Gc
Galvanic isolation
Bus see Statement of Conformity
Input see EC-Type Examination Certificate
Directive conformity
Directive 2014/34/EU EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010
International approvals of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock
IECEx approval IECEx PTB 05.0001 , IECEx PTB 05.0002X
Approved for Ex ia [ia Ga] IIC T4 Gb , [Ex ia Ga] IIC , [Ex ia Da] IIIC , Ex ic IIC T4 Gc , Ex nA IIC T4
Gc
Certificates and approvals
Marine approval DNV A-14038
General information of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock
Supplementary information EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity,
Attestation of Conformity and instructions have to be observed where applicable. For
information see www.pepperl-fuchs.com.
Similar Models of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock
RD0-TI-EX8.FF.ST-Y1
Temperature Multi-Input Device for Cabinet Installation
Temperature Multi-Input Device for Cabinet Installation
F2D0-TI-Ex8.FF.*
Temperature Multi-Input Device with Aluminum Housing
For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1
F2D0-TI-Ex8.PA.*
Temperature Multi-Input Device with Aluminum Housing
For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA
RD0-TI-Ex8.FF.*
Temperature Multi-Input Device for Cabinet Installation
For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1
RD0-TI-Ex8.PA.*
Temperature Multi-Input Device for Cabinet Installation
For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA
Product Description |
|
---|
Temperature Multi-Input Device for Cabinet Installation |
General specifications |
---|
Design / Mounting | Cabinet installation |
Fieldbus connection |
---|
Fieldbus type | FOUNDATION Fieldbus |
Mechanical specifications |
---|
Connection type | plug-in terminals , screw terminal |
Classifications
System | Classcode |
---|
ECLASS 11.0 | 27242610 |
ECLASS 10.0.1 | 27242610 |
ECLASS 9.0 | 27242610 |
ECLASS 8.0 | 27242610 |
ECLASS 5.1 | 27242610 |
ETIM 8.0 | EC001601 |
ETIM 7.0 | EC001601 |
ETIM 6.0 | EC001601 |
ETIM 5.0 | EC001604 |
UNSPSC 12.1 | 39121008 |
RD0-FB-EX4.COM |
RD0-FB-EX4 |
RD0-TI-EX8.FF.ST |
RD0-T1-EX8.FF.SC |
RD0-TI-EX8.FF.SC |
RD0-FR-EX4 |
RD0-FB.EX4 |
Windy Wang
HONGKONG XIEYUAN TECH CO., LIMITED
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com
Website: http://www.hkxytech.com/ | GMT/UTC +8