Pepperl+Fuchs
Pepperl+Fuchs Temperature Multi-Input Device for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 With Good Price In Stock

Pepperl+Fuchs Temperature Multi-Input Device for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 With Good Price In Stock

Model: RD0-TI-EX8.FF.ST-Y1

$1.00

Supplier: Products

Categories: Pepperl+Fuchs

After sales service. If you have any questions, click here.

Product Description

Pepperl+Fuchs Temperature Multi-Input Device for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 With Good Price In Stock


Product Features of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock


Temperature Multi-Input Device for Cabinet Installation

RD0-TI-Ex8.FF.*


  • < For 8 temperature or analog sensors
  • < Installation in Zone 1/Div. 1, intrinsically safe
  • < Sensors in Zone 0/Div. 1
  • < Connection to fieldbus acc. to FISCO or Entity
  • < For FOUNDATION Fieldbus H1
  • < PCS integration via device description and function blocks
  • < Concentrator method for simplified configuration
  • < Monitors sensor condition
  • < For T/C, RTD 2-, 3-, 4-wire, voltage and resistance
  • < Cold junction compensation
  • < Removable terminals


Product Function of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock


The Temperature Multi-Input (TM-I) for DIN rail installation connects up to 8 analog inputs to the DCS via fieldbus. It is installed in a typically prewired field enclosure close to the sensors in the hazardous area. The TM-I is certified intrinsically safe and as associated apparatus: inputs are intrinsically safe even when the fieldbus connection is not. Analog inputs can be resistance temperature sensors with 2, 3, and 4 wires, measuring sensors, thermocouples, or millivolt signals.


The TM-I communicates all data, configuration, and alarms via one fieldbus address and function blocks (8xAI or 1xMAI) to the DCS. For simplified configuration it supports the concentrator method: inputs can be configured all at once or individually. Fieldbus powers the sensors and the temperature interface itself, additional power or wiring is not required.


Cold junction compensation for thermocouples is integrated. The TM-I detects and reports lead breakage and short circuit conditions.



Technical Specification of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock


General specifications of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock


Design / Mounting Cabinet installation



Fieldbus interface of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock


Fieldbus type FOUNDATION Fieldbus
Physical layer profile profile type 511 (FISCO), profile type 111 (Entity)
ITK version 6.2.0 (DEV_REV 02)
1
Release
date:
2021-01-- 12 Date of
Release date: 2021-01-12 Date of issue: 2021-01-12 Filename: t158061_eng.pdf
Pepperl+Fuchs Group Germany: +49 621 776 2222
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
USA: +1 330 486 0002 Singapore: +65 6779 9091
www.pepperl-fuchs.com pa-info@us.pepperl-fuchs.com pa-info@de.pepperl-fuchs.com pa-info@sg.pepperl-fuchs.com
Technical Data
Implementation resource block1x RS
function block8x AI, 1x MAI
transducer block8x sensor TB, 1x concentrator TB
Execution time AI, MAI 40 ms max.
Macro cycle typical for one device 8xAI or 1xMAI max. 500 ms
Firmware update via separate plug connection
FDE (Fault Disconnect Equipment) 6.7 mA
Polarity not polarity sensitive
Rated voltage UN 9 ... 32 V
Rated current IN max. 23 mA



Indicators/operating means of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock


LED PWR green: on, bus voltage existent
LED COM ERR red, continuous lightning: hardware error; red, flashing: no bus activities or bus fault;
off: no error
LED CHANNEL ERROR red: 2 Hz flashing: lead breakage, overrange; off: no error



Input of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock


Number 8
Sensor types see table 1
Grounding grounding of thermoelements possible
Error detection lead breakage, wiring error, hardware device error
Common mode voltage Input to Input 600 Vpeak



Transfer characteristics of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock


Deviation
Cold junction compensation ± 0.5 °C (32.9 °F)
Resolution/accuracy see table 2
Influence of ambient temperature see table 3
Linearization T/C input 0.1°C RTD input 0.03°C
Internal measurement cycle for all sensor types max. 1 s



Galvanic isolation of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock


Fieldbus/inputs safe galvanic isolation acc. to EN 60079-11, voltage peak value 375 V


Directive conformity of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock


Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013



Standard conformity of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock


Galvanic isolation EN 60079-11
Electromagnetic compatibility NE 21:2011
Degree of protection IEC 60529
Fieldbus standard IEC 61158-2
Shock resistance EN 60068-2-27
Vibration resistance EN 60068-2-6



Ambient conditions of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock


Ambient temperature -40 ... 70 °C (-40 ... 158 °F) hazardous area
-40 ... 85 °C (-40 ... 185 °F) safe area
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Relative humidity ≤ 95 % non-condensing
Shock resistance 15 g , 11 ms
Vibration resistance 5 g , 10 ... 150 Hz
Corrosion resistance acc. to ISA-S71.04-1985, severity level G3



Mechanical specifications of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock


Connection type plug-in terminals , spring terminal and screw terminal
Core cross-section
Bus up to 2.5 mm2
Inputs up to 2.5 mm2
Housing material Polycarbonate
Degree of protection IP20
Mass 360 g
Mounting mounting on DIN rail in cabinet



Data for application in connection with hazardous areas of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock


EU-type examination certificate PTB 03 ATEX 2237
Marking 1 II 2 (1) G Ex ia [ia Ga] IIC T4 Gb , 1 II (1) G [Ex ia Ga] IIC , 1 II (1) D [Ex ia Da] IIIC
, 1 II 3 G Ex ic IIC T4 Gc
Bus FISCO see EC-Type Examination Certificate
Inputs see EC-Type Examination Certificate
Certificate PTB 03 ATEX 2238 X
Marking 1 II 3 G Ex nA IIC T4 Gc
Galvanic isolation
Bus see Statement of Conformity
Input see EC-Type Examination Certificate
Directive conformity
Directive 2014/34/EU EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010


International approvals of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock


IECEx approval IECEx PTB 05.0001 , IECEx PTB 05.0002X
Approved for Ex ia [ia Ga] IIC T4 Gb , [Ex ia Ga] IIC , [Ex ia Da] IIIC , Ex ic IIC T4 Gc , Ex nA IIC T4
Gc
Certificates and approvals
Marine approval DNV A-14038


General information of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock


Supplementary information EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity,
Attestation of Conformity and instructions have to be observed where applicable. For
information see www.pepperl-fuchs.com.

Similar Models of Pepperl+Fuchs RD0-TI-EX8.FF.ST-Y1 Temperature Multi-Input Devices for Cabinet Installation RD0-TI-EX8.FF.ST-Y1 Temperature Multi Input Junction Box In Stock


RD0-TI-EX8.FF.ST-Y1
Temperature Multi-Input Device for Cabinet Installation
Temperature Multi-Input Device for Cabinet Installation


F2D0-TI-Ex8.FF.*
Temperature Multi-Input Device with Aluminum Housing
For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1


F2D0-TI-Ex8.PA.*
Temperature Multi-Input Device with Aluminum Housing
For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA


RD0-TI-Ex8.FF.*
Temperature Multi-Input Device for Cabinet Installation
For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1


RD0-TI-Ex8.PA.*
Temperature Multi-Input Device for Cabinet Installation
For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA




Product Description
Temperature Multi-Input Device for Cabinet Installation
General specifications
Design / MountingCabinet installation
Fieldbus connection
Fieldbus typeFOUNDATION Fieldbus
Mechanical specifications
Connection typeplug-in terminals , screw terminal


Classifications


SystemClasscode
ECLASS 11.027242610
ECLASS 10.0.127242610
ECLASS 9.027242610
ECLASS 8.027242610
ECLASS 5.127242610
ETIM 8.0EC001601
ETIM 7.0EC001601
ETIM 6.0EC001601
ETIM 5.0EC001604
UNSPSC 12.139121008


Pepperl+Fuchs Temperature Multi-Input Device for Cabinet Installation RD0-TI-EX8.FF.ST-Y1


RD0-FB-EX4.COM
RD0-FB-EX4
RD0-TI-EX8.FF.ST
RD0-T1-EX8.FF.SC
RD0-TI-EX8.FF.SC
RD0-FR-EX4
RD0-FB.EX4


Windy Wang    

HONGKONG XIEYUAN TECH CO., LIMITED  
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com 
Website:  http://www.hkxytech.com/   | GMT/UTC +8



Related Products