Pepperl+Fuchs Temperature Multi-Input Device with Aluminum Housing F2D0-TI-Ex8.FF.* With Good Price In Stock
The FieldBarrier, a device coupler for DIN rail mounting, connects 4 instruments with intrinsic safety (Ex ia/Ex ib) and short circuit current limitation at each output. This ensures proper operation of the segment during faults or hot work at the spur. High power on the trunk enables maximum cable lengths and device count in any hazardous area. The integrated fieldbus terminator features high-availability design and is selectable. Output terminals with a choice of fixed or plug-in screw terminals connect 1 device each. LEDs simplify troubleshooting and help decrease repair time. Any grounding and shielding concept is possible based on FieldConnex® enclosure solutions.
Pepperl+Fuchs Temperature Multi-Input Device with Aluminum Housing F2D0-TI-Ex8.FF.*
For 8 temperature or analog sensors
Installation in Zone 1/Div. 1, intrinsically safe
Sensors in Zone 0/Div. 1
Connection to fieldbus acc. to FISCO or Entity
For FOUNDATION Fieldbus H1
PCS integration via device description and function blocks
Concentrator method for simplified configuration
Monitors sensor condition
For T/C, RTD 2-, 3-, 4-wire, voltage and resistance
Cold junction compensation
Removable terminals
Pepperl+Fuchs Temperature Multi-Input Device with Aluminum Housing F2D0-TI-Ex8.FF.*
General specifications | ||
---|---|---|
Design / Mounting | Outside installation | |
Electronic component | Temperature Multi-Input Device RD0-TI-Ex8.FF* For technical data on installed electronic component see data sheet. | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 | |
Standard conformity | ||
Galvanic isolation | EN 60079-11 | |
Electromagnetic compatibility | NE 21:2011 | |
Degree of protection | IEC 60529 | |
Fieldbus standard | IEC 61158-2 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Ambient conditions | ||
Ambient temperature | see table 1 | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | ≤ 95 % non-condensing | |
Shock resistance | 15 g , 11 ms | |
Vibration resistance | 10 g , 10 ... 150 Hz | |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Connection type | plug-in terminals , spring terminal and screw terminal | |
Core cross-section | ||
Bus | up to 2.5 mm2 | |
Inputs | up to 2.5 mm2 | |
Cable diameter | see table 2 | |
Cable gland | sensor inputs M16, fieldbus M20 | |
Housing material | EN 1780-1 46000 , ISO AlSi9Cu3(Fe) , anodized | |
Degree of protection | IP67 | |
Mass | 1800 g | |
Mounting | wall mounting |
RD0-FB-EX4.COM |
RD0-FB-EX4 |
RD0-TI-EX8.FF.ST |
RD0-T1-EX8.FF.SC |
RD0-TI-EX8.FF.SC |
RD0-FR-EX4 |
RD0-FB.EX4 |
Windy Wang
HONGKONG XIEYUAN TECH CO., LIMITED
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com
Website: http://www.hkxytech.com/ | GMT/UTC +8