Sensors
Pepperl+Fuchs Thru-beam sensor LA31/LK31/25/31/115 With Good Price In Stock

Pepperl+Fuchs Thru-beam sensor LA31/LK31/25/31/115 With Good Price In Stock

Model: LA31/LK31/25/31/115

$1.00

Supplier: Pepperl+Fuchs

Categories: Sensors

After sales service. If you have any questions, click here.

Product Description

Pepperl+Fuchs Thru-beam sensor LA31/LK31/25/31/115 With Good Price In Stock


  • Cost-optimized series for standard tasks

  • Large construction with small housing

  • Highly visible LED

  • Version for universal voltages

  • Relay output

  • Wide range of mounting options

Product Description of LA31/LK31/25/31/115
Thru-beam sensor, 30 m detection range, red light, light on, AC/DC version, relais output, fixed cable
System components
EmitterLA31/115
ReceiverLK31/25/31/115
General specifications
Effective detection range0 ... 30 m
Threshold detection range43 m
Light sourceLED
Light typemodulated visible red light , 630 nm
Alignment aidLED yellow:
1. LED illuminates: Sufficient light signal received, emitter and receiver alignment is correct
2. LED flashes: Reaching switching point
3. LED off: Light beam is interrupted or the alignment is out
Diameter of the light spotapprox. 800 mm at a distance of 30 m
Opening angleEmitter: 0.5 ° , Receiver: 1.5 °
Ambient light limit50000 Lux ; according EN 60947-5-2
Functional safety related parameters
MTTFd620 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
Operation indicatorLED green: power on
Function indicatorLED yellow:
1. LED lit constantly: signal > 2 x switching point (function reserve)
2. LED flashes: signal between 1 x switching point and 2 x switching point
3. LED off: signal < switching point
Electrical specifications
Operating voltage24 ... 240 V AC
12 ... 240 V DC
No-load supply currentEmitter: ≤ 20 mA
Receiver: ≤ 20 mA
Power consumptionEmitter: ≤ 1 VA
Receiver: ≤ 1 VA
Output
Switching typelight-on
Signal outputRelay, 1 alternator
Switching voltagemax. 250 V AC/DC
Switching currentmax. 3 A
Switching powerDC: max. 150 W AC: max. 750 VA
Switching frequency≤ 20 Hz
Response time≤ 25 ms
Conformity
Product standardEN 60947-5-2
Compliance with standards and directives
Standard conformity

StandardsEN 62103
Approvals and certificates
EAC conformityTR CU 020/2011
TR CU 004/2011
Protection classII , rated voltage ≤ 250 V AC with pollution degree 1-2 according to IEC 60664-1 Output circuit basis insulation of input circuit according to EN 50178, rated insulation voltage 240 V AC
CCC approvalCertified by China Compulsory Certification (CCC)
Ambient conditions
Ambient temperature-25 ... 55 °C (-13 ... 131 °F)
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
Mechanical specifications
Housing width18 mm
Housing height62 mm
Housing depth35 mm
Degree of protectionIP67
ConnectionEmitter: 2 m fixed cable , 2-wire
Receiver: 2 m fixed cable , 5-wire
Material

HousingPolycarbonate

Optical facePMMA
MassEmitter: 116 g
Receiver: 131 g

p+f la31 lk31 25 31 115_PP

Pepperl+Fuchs LA31/LK31/25/31/115

Thru-beam sensor

Thru-beam sensor, 30 m detection range, red light, light on, AC/DC version, relais output, fixed cable, Cost-optimized series for standard tasks, Large construction with small housing, Highly visible LED, Version for universal voltages, Relay output


Pepperl+Fuchs LA31/LK31/31/115

Thru-beam sensor

Thru-beam sensor, 30 m detection range, red light, dark on, AC/DC version, relais output, fixed cable, Cost-optimized series for standard tasks, Large construction with small housing, Highly visible LED, Version for universal voltages, Relay output


Pepperl+Fuchs LA31/LK31/16/25/31/115

Thru-beam sensor

Thru-beam sensor, 30 m detection range, red light, light on, sensitivity adjustment, AC/DC version, relais output, fixed cable, Cost-optimized series for standard tasks, Large construction with small housing, Highly visible LED, Version for universal voltages, Relay output


Pepperl+Fuchs LA31/LK31/25/31/115 SET

Thru-beam sensor

Photoelectric sensor for detecting people, objects and vehicles, Large construction with small housing, Not sensitive to ambient light, Version for universal voltages, Relay output, Construction type(S2): Rectangular type, Light source: LED, Light type: modulated visible red light , 630 nm, Operating voltage: 24 ... 240 V AC

12 ... 240 V DC, Signal output: Relay, 1 alternator, EAC conformity: TR CU 020/2011

TR CU 004/2011, CCC approval: Certified by China Compulsory Certification (CCC)


Pepperl+Fuchs LA31/LK31/25/31/115 SET2

Thru-beam sensor

Photoelectric sensor for detecting people, objects and vehicles, Large construction with small housing, Not sensitive to ambient light, Version for universal voltages, Relay output, Construction type(S2): Rectangular type, Light source: LED, Light type: modulated visible red light , 630 nm, Operating voltage: 24 ... 240 V AC

12 ... 240 V DC, Signal output: Relay, 1 alternator, EAC conformity: TR CU 020/2011

TR CU 004/2011, CCC approval: Certified by China Compulsory Certification (CCC)


PDE AND BRE


if you are intersted in more  product, Please feel free to contct below contact me :windy@hkxytech.com 


Windy Wang 
HONGKONG XIEYUAN TECH CO., LIMITED  
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com