CROWCON XGARD TYPE 1 FIXED GAS DETECTOR WITH GOOD PRICE IN STOCK
Oxygen or Toxic gas
IS approved
Zones 0, 1 or 2, Div 1 or 2
The Crowcon Xgard Type 1 is an Exia Intrinsically Safe toxic and oxygen gas detector using an electrochemical sensor within an Xgard enclosure, which also contains the amplifier/transmitter to provide a two-wire 4 to 20mA sink output. A Zener barrier or galvanic isolator is required for I.S. hazardous area operation.
Suitable for use with a range of cable glands; M20 or 1/2″ NPT or 3/4″ NPT. There is a choice of housing; glass-reinforced nylon, durable aluminium with a tough polyester coating, or 316 stainless steel suitable for deployment in extreme environments, such as offshore or in heavy industry- corrosion resistant.
Units can be installed on walls or ceilings, with three junction box choices—replacement sensors plugin. Accessories are available for duct mounting, sampling applications and remote gassing – simple sensor checking. In wash down areas or marine applications, splash guards and weatherproof caps are available.
Features of XGARD TYPE 1
Simple install and maintenance, common spares for all Xgard types, minimise inventory
Validated to IEC 61508 (SIL 1 to SIL 3)
Ingress protection IP65
Operating temperature -40 to +50°C (range varies for some sensor types)
Response time T90 <15s Oxygen. T90 <30s to 120s Toxic
Global approvals ATEX/ IECEx UL, INMETRO & GOST-R
Size 156 x 166 x 111 mm (6.1 x 6.5 x 4.3 inches)
Weight Nylon 0.5kg, Aluminium 1kg & Stainless Steel 3.1kg
Accessories
C011061 Accessory adaptor(spare) – M20 threaded adaptor for connecting other accessories
C01051 Collector cone – includes accessory adaptor. For aiding detection of light gases such as methane
C01052 Spray deflector – includes accessory adaptor. For outdoor installations & protection from water sprays
C01442 Weatherproof cap – includes accessory adaptor for use offshore or very wet environments
C01339 Flow adaptor, for use in sampling applications
C011063 Sun shield. Protects against excessive heat build-up due to direct sunlight. Supplied with fixing rivets
C03005 Calibration adaptor
S011918 Duct mounting kit. Stainless steel plate with 6mm remote calibration fitting. Max duct airflow: 6m/s
2575/1 Detector pulley system. Enables Xgard methane and hydrogen detectors to be lowered from a high level for calibration
00109A Calibration termination box (ABS box which enables gas to be applied to detectors remotely, a spray deflector or collector cone is also required)
M04214 PTFE tube 6 mm OD x 1 mm wall for use with calibration termination box
Enquire About This Product
Xgard Type 1: Intrinsically safe toxic and oxygen gas detector
Xgard Type 2: Flameproof toxic and oxygen gas detector
Xgard Type 3: Flameproof flammable gas detector
Xgard Type 4: Flameproof high temperature flammable gas detector
Xgard Type 5: Flameproof flammable gas detector with 4-20mA output
Xgard Type 6: Flameproof thermal conductivity type gas detector
Xsafe: Safe area flammable gas detector
Xgard The Xgard range of gas detectors has been specifically designed to meet your requirements. The dangers presented by toxic and flammable gases as well as oxygen deficiency vary with each application. Xgard offers three different sensor concepts so you can choose exactly what you need for your site. Xgard is available in flameproof, intrinsically safe or safe area formats for use in all environments, whatever the classification.
Low cost of ownership of XGARD TYPE 1
• Xgard detectors are designed for easy installation and maintenance to keep costs down.
• The three junction box options are all designed to make replacement of sensors and sinters extremely simple. Spare sensors simply plug-in.
• Many spare parts are common to all Xgard models, which keeps spares holding requirements to a minimum.
Wide range of sensors of XGARD TYPE 1
Xgard offers an extremely wide range of sensors for all applications:
• Poison resistant pellistors, for all flammable detection needs including hydrocarbons, hydrogen, ammonia, jet fuel, leaded petrol and vapours containing halogens.
• Electrochemical sensors are used to detect a vast range of toxic gases and oxygen.
• Thermal conductivity sensors are available to monitor volume concentrations of gases.
CROWCON XGARD TYPE 1 FIXED GAS DETECTOR WITH GOOD PRICE IN STOCK
Low cost of ownership of XGARD TYPE 1
Designed for easy installation and maintenance – keeps costs down
Three junction box options – designed to make replacement of sensors and sinters extremely simple. Spare sensors simply plug-in
Many spare parts are common to all Xgard models – keeps spares holding requirements to a minimum
Flexible installation options of XGARD TYPE 1
Designed for either wall or ceiling mounting – no need for additional brackets
Can accommodate M20, 1/2″ NPT or 3/4″ NPT cable glands – suits all site requirements
High temperature models are available for hot environments (up to 150oc)
Accessories are available for duct mounting and sampling applications as well as remote gassing – simple sensor checking
Wide range of sensors of XGARD TYPE 1
Poison resistant pellistors, for all flammable detection needs including hydrocarbons, hydrogen, ammonia, jet fuel, leaded petrol and vapours containing halogens
Electrochemical sensors are used to detect a vast range of toxic gases and oxygen
Thermal conductivity sensors are available to monitor % volume concentrations of gases
Rugged and reliable of XGARD TYPE 1
Manufactured using a choice of three materials: glass reinforced nylon, highly durable aluminium with a tough polyester coating, or 316 stainless steel for ultimate corrosion resistance – designed to operate even in the harshest environments
Spray deflectors and weatherproof caps are available for use in areas subject to regular wash-downs, or offshore environments
All models have been validated to the functional safety standard IEC 61508 (SIL 1 to SIL 3)
XG1-N1-01-CU | Hexane 0-100% LEL C6H14(IR) |
XG1-N1-01-FY | Hexane 0-100%LEL |
XG1-N1-01-FA | Hydrogen 0-100%LEL |
XG1-N1-01-TQ | Hydrogen 0-20000ppm (0-50% LEL) H2 |
XG1-N1-01-AQ | Hydrogen 0-2000ppm H2 |
XG1-N1-01-AP | Hydrogen 0-200ppm H2 |
XG1-N1-01-FS | Hydrogen 0-25%LEL |
XG1-N1-01-TF | Hydrogen 0-40000ppm (0-100% LEL) H2 |
XG1-N1-01-SW | Hydrogen chloride 0-10ppm HCl |
XG1-N1-01-SX | Hydrogen chloride 0-25ppm HCl |
XG1-N1-01-TG | Hydrogen chloride 0-5ppm HCl |
XG1-N1-01-SY | Hydrogen cyanide 0-25ppm HCl |
XG1-N1-01-AV | Hydrogen fluoride 0-10ppm HF |
XG1-N1-01-AG | Hydrogen sulphide 0-1000ppm H2S |
XG1-N1-01-AC | Hydrogen sulphide 0-100ppm H2S |
XG1-N1-01-TJ | Hydrogen sulphide 0-10ppm H2S |
XG1-N1-01-AD | Hydrogen sulphide 0-200ppm H2S |
XG1-N1-01-TK | Hydrogen sulphide 0-20ppm H2S |
XG1-N1-01-AE | Hydrogen sulphide 0-250ppm H2S |
XG1-N1-01-AA | Hydrogen sulphide 0-25ppm H2S |
XG1-N1-01-AF | Hydrogen sulphide 0-300ppm H2S |
XG1-N1-01-AB | Hydrogen sulphide 0-50ppm H2S |
XG1-N1-01-TI | Hydrogen sulphide 0-5ppm H2S |
XG1-N1-01-FV | hydrogen: 0-10% vol. in air |
XG1-N1-01-FT | hydrogen: 0-20% vol. in nitrogen |
XG1-N1-01-TBA | hydrogen: 0-25% vol. in nitrogen |
XG1-N1-01-TBA | hydrogen: 0-30% vol. in nitrogen |
XG1-N1-01-TBA | hydrogen: 0-5% vol. in air |
XG1-N1-01-TBA | hydrogen: 0-50% vol. in air |
XG1-N1-01-FU | hydrogen: 0-50% vol. in nitrogen |
XG1-N1-01-FK | IPA 0-100%LEL |
XG1-N1-01-FR | Jet Fuel 0-100%LEL |
XG1-N1-01-CV | LPG 0-100% LEL(IR) |
XG1-N1-01-FW | LPG 0-100%LEL |
XG1-N1-01-BJ | Methane 0-100% LEL CH4(IR) |
XG1-N1-01-FD | Methane 0-100%LEL |
XG1-N1-01-BC | Methanol 0-100% LEL CH3OH(IR) |
XG1-N1-01-FL | Methanol 0-100%LEL |
XG1-N1-01-SP | Nitric oxide 0-100ppm NO |
XG1-N1-01-SN | Nitric oxide 0-25ppm NO |
XG1-N1-01-SO | Nitric oxide 0-50ppm NO |
XG1-N1-01-SM | Nitrogen dioxide 0-100ppm NO2 |
XG1-N1-01-SK | Nitrogen dioxide 0-10ppm NO2 |
XG1-N1-01-SL | Nitrogen dioxide 0-50ppm NO2 |
XG1-N1-01-OA | Oxygen 0-25% vol O2 |
XG1-N1-01-HA | Ozone 0-1ppm O3 |
XG1-N1-01-CX | Pentane 0-100% LEL C5H12(IR) |
XG1-N1-01-FI | Pentane 0-100%LEL |
XG1-N1-01-FN | Petrol Vapour (leaded) 0-100%LEL |
XG1-N1-01-FF | Petrol Vapour (unleaded) 0-100%LEL |
XG1-N1-01-TN | Phosgene, 0-1ppm |
XG1-N1-01-TM | Phosphine 0-1ppm PH3 |
XG1-N1-01-BN | Propane 0-100% LEL C3H8(IR) |
XG1-N1-01-FH | Propane 0-100%LEL |
XG1-N1-01-TP | Silane 0-1ppm SiH4 |
XG1-N1-01-ST | Sulphur dioxide 0-100ppm SO2 |
XG1-N1-01-SQ | Sulphur dioxide 0-10ppm SO2 |
XG1-N1-01-SR | Sulphur dioxide 0-20ppm SO2 |
XG1-N1-01-SV | Sulphur dioxide 0-250ppm SO2 |
XG1-N1-01-SS | Sulphur dioxide 0-50ppm SO2 |
XG1-N1-01-FJ | Toluene 0-100%LEL |
XG1-N1-01-FO | VCM 0-100%LEL |
XG1-N1-01-TO | Volatile organics 0-100ppm VO |
if you are intersted in more Phoenix Contact product, Please feel free to contct below contact me :windy@hkxytech.com
Windy Wang
HONGKONG XIEYUAN TECH CO., LIMITED
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com
Website: http://www.hkxytech.com/ | GMT/UTC +8