Honeywell SPXCDDM4 Replacement display module for RTD (4~20mA) With Best Price In Stock
Each replacement Display Module includes pre-configured PCB (for sensor and range), backlit LCD and plastic housing. The unit is a plug in replacement and simply requires confiiguration after fitting via the menu.
Sensepoint XCD of SPXCDDM4
Sensepoint XCD with Flammable and Primary Toxic Sensor Cartridge
Honeywell SPXCDDM4
Sensepoint XCD-RTD transmitter (use with oxygen and toxic Sensepoint sensors) |
Sensepoint XCD-RTD (Remote Toxic Detector) allows for a gas sensor from a wider selection of 2-wire 4 to 20 mA input type Toxic and Oxygen sensors to be fitted directly to the transmitter housing, or wired remotely from another location. KIT includes Transmitter, Magnetic Wand and Allen Key |
INSTRUMENT |
Without Modbus |
SPXCDALMTX4 ATEX, IECEx & AP approved SP XCD-RTD 4~20mA Input Transmitter, 2 x M20 Entries, 1 x M25 Entry, painted LM25 |
SPXCDASMTX4 ATEX, IECEx & AP approved SP XCD-RTD 4~20mA Input Transmitter, 2 x M20 Entries, 1 x M25 Entry, painted 316SS |
SPXCDULNTX4 cCSAus approved SP XCD-RTD 4~20mA Input Transmitter, 3 x 3/4'' NPT Entries, painted LM25 |
SPXCDUSNTX4 cCSAus approved SP XCD-RTD 4~20mA Input Transmitter, 3 x 3/4'' NPT Entries, painted 316SS |
With Modbus |
SPXCDALMTX4M ATEX, IECEx & AP approved SP XCD-RTD 4~20mA Input Transmitter with MODBUS, 2 x M20 Entries, 1 x M25 Entry, painted LM25 |
SPXCDASMTX4M ATEX, IECEx & AP approved SP XCD-RTD 4~20mA Input Transmitter with MODBUS, 2 x M20 Entries, 1 x M25 Entry, painted 316SS |
SPXCDULNTX4M cCSAus approved SP XCD-RTD 4~20mA Input Transmitter with MODBUS, 3 x 3/4'' NPT Entries, painted LM25 |
SPXCDUSNTX4M cCSAus approved SP XCD-RTD 4~20mA Input Transmitter with MODBUS, 3 x 3/4'' NPT Entries, painted 316SS |
Note: Refer to "Sensepoint" pricelist for the new M25 for ATEX/IECEx and 3/4''NPT for cCSA threaded range of Sensepoint Toxic sensors that may be fitted directly to the 4-20mA input XCD-RTD transmitter. |
Sensepoint XCD-RFD transmitter (use with Standard & Hi-Temp Sensepoint sensors) |
Sensepoint XCD-RFD (Remote Flammable Detector) allows for remotely mounted flammable gas detectors such as Hi-Temperature version of Sensepint Flamable to be located in adverse applications and monitored from a convenient location. KIT includes Transmitter, Magnetic Wand and Allen Key |
INSTRUMENT |
Without Modbus |
SPXCDALMRFD ATEX, IECEx & AP approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input Transmitter, 2 x M20 Entries,1 x M25 Entry,painted LM25 |
SPXCDASMRFD ATEX, IECEx & AP approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input Transmitter, 2 x M20 Entries,1 x M25 Entry,painted 316SS |
SPXCDULNRFD cCSAus approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input Transmitter, 3 x 3/4'' NPT Entries, painted LM25 |
SPXCDUSNRFD cCSAus approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input Transmitter, 3 x 3/4'' NPT Entries, painted 316SS |
With Modbus |
SPXCDALMRFDM ATEX, IECEx & AP approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input Transmitter with MODBUS, 2 x M20 Entries, 1 x M25 Entry, paited LM25 |
SPXCDASMRFDM ATEX, IECEx & AP approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input Transmitter with MODBUS, 2 x M20 Entries, 1 x M25 Entry, paited 316SS |
SPXCDULNRFDM cCSAus approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input Transmitter with MODBUS, 3 x 3/4'' NPT Entries, painted LM25 |
SPXCDUSNRFDM cCSAus approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input Transmitter with MODBUS, 3 x 3/4'' NPT Entries, painted 316SS |
Remote Flammable Sensor (XCD Sensor Cartridge + Socket Housing) |
SPXCDXSRFXSS Flammable CAT 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) Sensor Cartridge with Socket Housing |
SPXCDXSRRXSS Methane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) Sensor Cartridge with Socket Housing |
SPXCDXSRPXSS Propane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) Sensor Cartridge with Socket Housing |
SPXCDXSRB1SS Carbon Dioxide IR 0-2.00%VOL only with Socket Housing Sensor Cartridge with Socket Housing |
SPXCDXSRB2SS Carbon Dioxide IR 0-5.00%VOL only with Socket Housing Sensor Cartridge with Socket Housing |
00780-A-0100 Term Hsg-Bartec DE1155 With Continuity Plate 1x25mm- 3x20mm Entries (ATEX certified) |
Sensepoint XCD |
ACCESSORIES, CONSUMABLES & SPARES |
ACCESSORIES |
S3KCAL Calibration cap |
SPXCDCC Collecting cone for use with lighter than air gases |
SPXCDDMK Duct mounting kit |
SPXCDMTBR Mounting bracket (inc. bolts, nuts, brackets) |
SPXCDSDP Sunshade / Deluge Protection |
SPXCDFH Flow Housing for Sample Panel |
Consumables |
SPXCDXSFXSS Flammable CAT 0-100%LEL (20,0 to 100.0%LEL) |
SPXCDXSRXSS CH4(Methane) IR 0-100%LEL (20,0 to 100.0%LEL) |
SPXCDXSPXSS C3H8 (Propane) IR 0-100%LEL (20,0 to 100.0%LEL) |
SPXCDXSO1SS Oxygen 25.0%/Vol only |
SPXCDXSHXSS Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm) |
SPXCDXSCXSS Carbon Monoxide 0-300ppm (100 to 1000ppm) |
SPXCDXSG1SS Hydrogen 0-1000ppm only |
SPXCDXSNXSS Nitrogen Dioxide 10-50ppm (10.0 to 50.0ppm) |
SPXCDXSB1SS Carbon Dioxide IR 0-2%VOL only |
SPXCDXSB2SS Carbon Dioxide IR 0-5%VOL only |
Spares (Miscellaneous) |
SPXCDWP Sensepoint XCD Standard Weather Protection |
SPXCDSRLS Sensor Retainer with locking screw |
SPXCDAKS Allen key for stopper |
SPXCDHWES Hex wrench for earth screw |
SPXCDEBS Earth Bracket and Screws |
SPXCDMAG Magnetic wand |
SPXCDRSSH Sensor Socket Housing for XCD |
SPXCDMBUS Replacement Modbus Module |
SPXCDSERVK Service Kit, Including O-ring front cover (2 pieces), Terminal module screw (3 pieces), Earth screw and bracket (2 pieces), O-ring weather housing, O-ring cardridge retainer (2 pieces), O-ring on the cartridge (2 pieces), Locking screw for front cover and sensor retainer (2 pieces) |
SPXCDTOOLK XCD Service Tool Kit, Including Magnet, Hex wrench for earth screw and Allen key for locking screws |
SPXCDTMK XCD Terminals Kit, Including Terminal block for relays (green) and Terminal block power |
SPXCDNPTP 3/4"NPT plug (Certified as part of Ex d enclosure) |
SPXCDM20P M20 plug (Certified as part of Ex d enclosure) |
Spares (Replacement Display Module) |
Each replacement Display Module includes pre-configured PCB (for sensor and range), backlit LCD and plastic housing. The unit is a plug in replacement and simply requires confiiguration after fitting via the menu. |
SPXCDDMT Replacement display module for O2 & Toxic |
SPXCDDMF Replacement display module for FL & IR |
SPXCDDM4 Replacement display module for RTD (4~20mA) |
SPXCDDMR Replacement display module for RFD |
SPXCDDMT12 Replacement O2 & Toxic display module Without Modbus for 12-32 Vdc |
SPXCDDMF12 Replacement FL & IR display module Without Modbus for 12-32 Vdc |
SPXCDDMTM12 Replacement O2 & Toxic display module with Modbus for 12-32 Vdc |
SPXCDDMFM12 Replacement FL & IR display module with Modbus for 12-32 Vdc |
SPXCDDMTM Replacement display module for O2 & Toxic with Modbus |
SPXCDDMFM Replacement display module for FL & IR with Modbus |
SPXCDDM4M Replacement display module for RTD with Modbus |
SPXCDDMRM Replacement display module for RFD with Modbus |
Spares (Replacement Terminal Module) |
Each replacement terminal module includes pre-configured PCB (for sensor and range), terminals, screws, 'U' clamp, plastic cover and fixing screws. |
SPXCDTMO Replacement terminal module for O2 |
SPXCDTMT Replacement terminal module for Toxic |
SPXCDTMF Replacement terminal module for FL & IR |
SPXCDTMO12 Replacement O2 terminal module for 12-32 Vdc |
SPXCDTMT12 Replacement Toxic terminal module for 12-32 Vdc |
SPXCDTMF12 Replacement FL & IR terminal module for 12-32 Vdc |
SPXCDTM4 Replacement terminal module for RTD (4~20mA) |
SPXCDTMR Replacement terminal module for RFD |
Spares (ATEX APPROVAL Replacement XCD STD version Transmitter only without MODBUS ) |
SPXCDALMTXO ATEX/IECEX & AP approved SP XCD O2 Transmitter with LM25, M20 Entry |
SPXCDALMTXT ATEX/IECEX & AP approved SP XCD Toxic Transmitter with LM25, M20 Entry |
SPXCDALMTXF ATEX/IECEX & AP approved SP XCD FL/IR Transmitter with LM25, M20 Entry |
SPXCDASMTXO ATEX/IECEX & AP approved SP XCD O2 Transmitter with SS316, M20 Entry |
SPXCDASMTXT ATEX/IECEX & AP approved SP XCD Toxic Transmitter with SS316, M20 Entry |
SPXCDASMTXF ATEX/IECEX & AP approved SP XCD FL/IR Transmitter with SS316, M20 Entry |
Spares (ATEX APPROVAL Replacement XCD STD version Transmitter only with MODBUS ) |
SPXCDALMTXOM ATEX/IECEX & AP approved SP XCD O2 Transmitter with LM25, M20 Entry |
SPXCDALMTXTM ATEX/IECEX & AP approved SP XCD Toxic Transmitter with LM25, M20 Entry |
SPXCDALMTXFM ATEX/IECEX & AP approved SP XCD FL/IR Transmitter with LM25, M20 Entry |
SPXCDASMTXOM ATEX/IECEX & AP approved SP XCD O2 Transmitter with SS316, M20 Entry |
SPXCDASMTXTM ATEX/IECEX & AP approved SP XCD Toxic Transmitter with SS316, M20 Entry |
SPXCDASMTXFM ATEX/IECEX & AP approved SP XCD FL/IR Transmitter with SS316, M20 Entry |
Spares (UL APPROVAL Replacement XCD STD version Transmitter only without MODBUS ) |
SPXCDULNTXO UL approved SP XCD O2 Transmitter with LM25, 3/4"NPT Entry |
SPXCDULNTXT UL approved SP XCD Toxic Transmitter with LM25, 3/4"NPT Entry |
SPXCDULNTXF UL approved SP XCD FL/IR Transmitter with LM25, 3/4"NPT Entry |
SPXCDUSNTXO UL approved SP XCD O2 Transmitter with SS316, 3/4"NPT Entry |
SPXCDUSNTXT UL approved SP XCD Toxic Transmitter with SS316, 3/4"NPT Entry |
SPXCDUSNTXF UL approved SP XCD FL/IR Transmitter with SS316, 3/4"NPT Entry |
Spares (UL APPROVAL Replacement XCD STD version Transmitter only with MODBUS ) |
SPXCDULNTXOM UL approved SP XCD O2 Transmitter with LM25, 3/4"NPT Entry |
SPXCDULNTXTM UL approved SP XCD Toxic Transmitter with LM25, 3/4"NPT Entry |
SPXCDULNTXFM UL approved SP XCD FL/IR Transmitter with LM25, 3/4"NPT Entry |
SPXCDUSNTXOM UL approved SP XCD O2 Transmitter with SS316, 3/4"NPT Entry |
SPXCDUSNTXTM UL approved SP XCD Toxic Transmitter with SS316, 3/4"NPT Entry |
SPXCDUSNTXFM UL approved SP XCD FL/IR Transmitter with SS316, 3/4"NPT Entry |
Special Flammable Gas Calibrations |
SPXCDSFGC1 Special Flammable Gas Calibration, 0-100%LEL |
SPXCDSFGC2 Special Flammable Gas Calibration, 0-100%LEL |
SPXCDSFGC3 Special Flammable Gas Calibration, 0-100%LEL |
SPXCDSFGC4 Special Flammable Gas Calibration, 0-100%LEL |
SPXCDSFGC5 Special Flammable Gas Calibration, 0-100%LEL |
SPXCDSFGC6-H Special Flammable Gas Calibration, 0-100%LEL,6* - Hydrogen |
SPXCDSFGC7 Special Flammable Gas Calibration, 0-100%LEL |
SPXCDSFGC8 Special Flammable Gas Calibration, 0-100%LEL if you are intersted in more Allen-Bradley product, Please feel free to contct below contact me :windy@hkxytech.com Windy Wang |