IFM O1D100 Photoelectric distance sensor With Good Price In Stock
Feature of O1D100
Reliable optical distance measurement with high ranges up to 10 m
Two switching outputs, one of them programmable as analogue output
Scalable measuring range and window function
Use in applications with background suppression
Excellent price/performance ratio
Product characteristics of O1D100 | |
---|---|
Laser protection class | 2 |
Housing | rectangular |
Electrical data of O1D100 | |
Operating voltage [V] | 18...30 DC; (operating voltage "supply class 2" according to cULus) |
Current consumption [mA] | < 150 |
Protection class | III |
Reverse polarity protection | yes |
Typ. lifetime [h] | 50000 |
Inputs / outputs of O1D100 | |
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Outputs | |
Total number of outputs | 2 |
Electrical design | PNP |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (parameterisable) |
Max. current load per output [mA] | 200 |
Number of analogue outputs | 1 |
Analogue current output [mA] | 4...20; (IEC 61131-2) |
Max. load [Ω] | 250 |
Analogue voltage output [V] | 0...10; (IEC 61131-2) |
Min. load resistance [Ω] | 5000 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Detection zone | |
Max. light spot width [mm] | 15 |
Max. light spot height [mm] | 15 |
Light spot dimensions refer to | 10 m |
Background suppression [m] | 0...19 |
Measuring/setting range | |
Measuring range [m] | 0.2...10; (white paper 200 x 200 mm 90% remission) |
Sampling rate [Hz] | 1...50 |
Interfaces | |
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 |
Profiles | Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis |
SIO mode | yes |
Required master port type | A |
Process data analogue | 2 |
Process data binary | 3 |
Min. process cycle time [ms] | 6 |
Supported DeviceIDs | Type of operationDeviceIDDefault806 |
Operating conditions | |
Ambient temperature [°C] | -10...60 |
Protection | IP 67 |
Tests / approvals | |
EMC | EN 60947-5-2 |
Laser protection class | 2 |
Notes on laser protection | Caution:laser lightPower:<= 4 mWWave length:650 nmpulse:1,3 nsDo not stare into beam.Avoid exposure to the laser light.laser class:2EN / IEC60825-1:2007EN / IEC60825-1:2014Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007. |
MTTF [years] | 182 |
Mechanical data | |
Weight [g] | 303 |
Housing | rectangular |
Dimensions [mm] | 59 x 42 x 52 |
Materials | housing: diecast zinc; front lens: glass; LED window: PC |
Lens alignment | side lens |
Displays / operating elements | |
Display | switching status2 x LED, yellowoperationLED, greendistance value, programmingalphanumeric display, 4-digit |
Accessories | |
Accessories (optional) | Protective cover, E21133 |
Remarks | |
Remarks | For more information about the measuring range / application please refer to the operating instructions. |
Pack quantity | 1 pcs. |
Electrical connection | |
Connection | Connector: 1 x M12 |
Other data | |
ParameterSetting rangeFactory settingUnimm, m, inchmmOU1Hno, Hnc, Fno, FncHnoSP1 [mm]200...99991000nSP1 [mm]200...9999800FSP1 [mm]200...99991200OU2Hno, Hnc, Fno, Fnc, I, UISP2 [mm]200...99992000nSP2 [mm]200...99991800FSP2 [mm]200...99992200ASP [mm]0...99990AEP [mm]0...99999999rATE [Hz]1...5050dS1 [s]0...0.1...50dr1 [s]0...0.1...50dS2 [s]0...0.1...50dr2 [s]0...0.1...50dFo [s]0...0.1...50dISd1...3 ; rd1...3; OFFd3 | |
repeatability/accuracy | |
read/write distance (mm)repeatability of the measured valuesAccuracywhite (90 % remission)grey (18 % remission)white (90 % remission)grey (18 % remission)200...1000 mm± 5.0 mm±7.5 mm± 15.0 mm± 18.0 mm1000...2000 mm± 5.5 mm±10.0 mm± 15.0 mm± 20.0 mm2000...4000 mm± 17.5 mm±22.5 mm± 25.0 mm± 32.0 mm4000...6000 mm± 27.5 mm±40.0 mm± 35.0 mm± 50.0 mm6000...10000 mm± 60.0 mm± 70.0mm | |
Sampling rate50 HzExtraneous light on the object< 40 klx | |
repeatability/accuracy | |
read/write distance (mm)repeatability of the measured valuesAccuracywhite (90 % remission)grey (18 % remission)white (90 % remission)grey (18 % remission)200...1000 mm± 16.5 mm±16.5 mm± 26.5 mm± 26.5 mm1000...2000 mm± 16.5 mm±16.5 mm± 26.5 mm± 26.5 mm2000...4000 mm± 30.0 mm±37.0 mm± 40.0 mm± 47.0 mm4000...6000 mm± 37.0 mm±57.0 mm± 47.0 mm± 67.0 mm6000...10000 mm± 75.0 mm—± 85.0mm— | |
Sampling rate50 HzExtraneous light on the object40...100 klx | |
repeatability/accuracy | |
read/write distance (mm)repeatability of the measured valuesAccuracywhite (90 % remission)grey (18 % remission)white (90 % remission)grey (18 % remission)200...1000 mm± 4.0 mm±4.5 mm± 14.0 mm± 15.0 mm1000...2000 mm± 4.5 mm±6.0 mm± 14.5 mm± 16.0 mm2000...4000 mm± 13.5 mm±14.5 mm± 23.5 mm± 24.0 mm4000...6000 mm± 19.0 mm±21.0 mm± 29.0 mm± 31.0 mm6000...10000 mm± 37.0 mm–± 47.0mm– | |
Sampling rate1 HzExtraneous light on the object< 40 klx | |
repeatability/accuracy | |
read/write distance (mm)repeatability of the measured valuesAccuracywhite (90 % remission)grey (18 % remission)white (90 % remission)grey (18 % remission)200...1000 mm± 10.0 mm± 10.0 mm± 20.0 mm± 20.0 mm1000...2000 mm± 10.0 mm± 10.0 mm± 20.0 mm± 20.0 mm2000...4000 mm± 17.0 mm± 18.0 mm± 27.0 mm± 28.0 mm4000...6000 mm± 22.0 mm± 25.0 mm± 32.0 mm± 35.0 mm6000...10000 mm± 37.0 mm–± 47.0mm– | |
Sampling rate1 HzExtraneous light on the object< 40...100 klx--Range on black object (6 % remission)<= 4000 mm--The values apply atconstant ambient conditions23 °C / 960 hPaminimum power-on time in minutes10 |
if you are intersted in more Allen-Bradley product, Please feel free to contct below contact me :windy@hkxytech.com
Windy Wang
HONGKONG XIEYUAN TECH CO., LIMITED
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com
Website: http://www.hkxytech.com/ | GMT/UTC +8