100% Original MTL3081 MILLIVOLT ISOLATOR for low-level signals In Good Price Ready To Ship
The MTL3081 takes the signal from a thermocouple or dc millivolt source in a hazardous area, isolates it, and passes it on to the receiving instrument in the safe area. It is ideally suited to applications where the thermocouple signal is fed directly into the receiving instrument, rather than converted beforehand into 4/20mA. The safety drive, which is optional, can be enabled by a link to initiate either a high or low output in the event of thermocouple burnout or cable breakage. The direction of the safety drive is set by a switch in the top of the unit. The unit is very easy to use since its ±50mV input range is sufficient to cope with all common thermocouple outputs, and so there are no calibration procedures to worry about. Furthermore, its input terminals are non-energy-storing which allows installation in virtually any IS system without further certification.
MTL3081 MILLIVOLT ISOLATOR for low-level signals.The MTL3081 takes the signal from a thermocouple or dc millivolt source in a hazardous area, isolates it, and passes it on to thereceiving instrument
SPECIFICATION of MTL3081
See also 'Common specification'
Number of channels
One, fully floating
Signal source
Any dc millivolt source
Location of thermocouple
Zone 0, IIC, T4 hazardous area
Div 1, Group A, hazardous location
Location of millivolt source
Zone 0, IIC, T4 hazardous area if suitably certified
Div 1, Group A, hazardous location
Input and output signal range
0 to ±50mV
Output impedance
≤250Ω
Transfer accuracy at 20°C
0.05% of reading (input ≥ ±10mV)
±5µV (input < ±10mV)
Temperature drift (with source impedance of <500Ω)
(1µV + 0.002% of input) per °C, typically
(2µV + 0.004% of input) per °C, maximum
Response time
Settles to within 10% of final value after typically 50ms
Safety drive on THC burnout (selectable)
Upscale or downscale at >10mV/s, or off
Power requirement
10mA maximum at 20 to 35V
Power dissipation within unit
0.35W maximum at 35V
Replaceable fuse
50mA, 5x20mm glass to DIN 41571 sht. 2, semi-time-lag (M)
Safety description
Input terminals (Nos. 5 & 6): non-energy-storing apparatus
(≤1.2V, ≤0.1A, ≤20µJ and ≤25mW). Can be connected
without further certification into any IS loop with opencircuit voltage not more than 28V.
FM max entity parameters
Voc = 1.2V, Isc = 22.5mA, Ca = 1000µF, La = 75mH
Weight
170g
MTL3992
MTL3099
MTL3081
MTL3073
MTL3072
MTL3071
MTL3058
MTL3059
MTL3054
MTL3052
MTL3046B
MTL3045
MTL3043
MTL3042
MTL3041
MTL3021
MTL3014
MTL3013
MTL3011
if you are intersted in more Allen-Bradley product, Please feel free to contct below contact me :windy@hkxytech.com
Windy Wang
HONGKONG XIEYUAN TECH CO., LIMITED
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com
Website: http://www.hkxytech.com/ | GMT/UTC +8