MTL
100% Original MTL3054 AND MTL3055 COMMUNICATIONS ISOLATORS/REPEATERS In Good Price Ready To Ship

100% Original MTL3054 AND MTL3055 COMMUNICATIONS ISOLATORS/REPEATERS In Good Price Ready To Ship

Model: MTL3054

$1.00

Supplier: Products

Categories: MTL

After sales service. If you have any questions, click here.

Product Description

100% Original MTL3054 AND MTL3055 COMMUNICATIONS ISOLATORS/REPEATERS In Good Price Ready To Ship


MTL3054 AND MTL3055 COMMUNICATIONS ISOLATORS/REPEATERS.The MTL3054 and 3055 enable the extension of LONWORKS® into hazardous areas. The units provide power and communications via the signal conductor


The MTL3054 and 3055 enable the extension of LONWORKS® into hazardous areas. The units provide power and communications via the signal conductors. MTL3054: the number of devices that can be supported is a function of the power required by each device. MTL3055: two units may be used for communication across hazardous areas or for communication to LONWORKS nodes mounted in explosionproof (flameproof) enclosures in a hazardous area. Two MTL3055s may be used to give dual-redundant connection to a hazardous-area node.


SPECIFICATION OF MTL3054

See also 'Common specification'

Location of field devices (MTL3054)

Zone 0, IIC, T4–6 hazardous area if suitably certified

Location of field devices (MTL3055)

Zone 0, IIC, T4–6 hazardous area if suitably certified

Zone 0, IIC, T4–6 hazardous area if suitably certified when two

MTL3055s are connected together.

Hazardous-area power supply (MTL3054)

19.4V, 105Ω dc impedance typical

Maximum current 90mA

Hazardous-area power supply (MTL3055)

19.4V, 210Ω dc impedance typical

Maximum current 45mA

Hazardous-area maximum cable length

Determined by IS requirements depending upon devices attached

and maximum acceptable voltage drop along cable.

Free topology: 300m maximum (provisional value)

Bus topology: 1000m maximum

Hazardous-area digital signal transmission

78.1kbit/s, carried on same wires as power.

Signals are repeated between safe-area LONWORKS physical channel and IS physical channel.

Safe-area transceiver (MTL3054)

Similar to TP-78 devices with additional safety components required

by IS regulations. Operates with conventional TP-78 transceivers

but maximum number of nodes and maximum bus length are reduced.

Power requirement (MTL3054)

140mA typical at 24V with full load

110mA at 35V to 170mA at 20V with full load

Power requirement (MTL3055)

100mA typical at 24V with full load

90mA at 35V to 130mA at 20V with full load

Power dissipation within unit

2.5W typical at 24V with full load

2.8W maximum at 35V with full load

Replaceable fuse

250mA

Weight

170g

Safety description (MTL3054)

Terminals 5 to 6 and 7 to 8

22V, 102Ω, 216mA, Um = 250V rms or dc

Safety description (MTL3055)

Terminals 5 to 6 and 7 to 8

22V, 200Ω, 110mA, Um = 250V rms or dc


MTL3054

MTL3992

MTL3099

MTL3081

MTL3073

MTL3072

MTL3071

MTL3058

MTL3059

MTL3054

MTL3052

MTL3046B

MTL3045

MTL3043

MTL3042

MTL3041

MTL3021

MTL3014

MTL3013

MTL3011


PDE AND BRE


if you are intersted in more Allen-Bradley product, Please feel free to contct below contact me :windy@hkxytech.com 


Windy Wang 
HONGKONG XIEYUAN TECH CO., LIMITED  
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com 
Website:  http://www.hkxytech.com/   | GMT/UTC +8