100% Original MTL3046B REPEATER POWER SUPPLY, 4/20mA for "smart" transmitters In Good Price Ready To Ship
MTL3046B REPEATER POWER SUPPLY, 4/20mA for ‘smart’ transmitters.The MTL3046B performs a similar function to the MTL3041, but is tailored for use with ‘smart’ transmitters whose digital communicati
The MTL3046B performs a similar function to the MTL3041, but is tailored for use with smart transmitters whose digital communication signals are superimposed on a standard 4/20mA analogue signal. The unit provides a minimum of 15V at 20mA to energise the transmitter while at the same time repeating the current accurately in a separate circuit to drive a load in the safe area. The transmitter can be calibrated, interrogated or tested from the host computer, or by using a hand-held communicator connected in either the safe or hazardous area. The MTL3046B is a development of the MTL3046, which it replaces, and it is compatible with the majority of smart transmitters available.
SPECIFICATION OF MTL3046B
See also 'Common specification'
Number of channels
One, fully floating
Location of transmitter
Zone 0, IIC, T46 hazardous area if suitably certified
Div 1, Group A, hazardous location
Voltage available for transmitter and lines
15V minimum at 20mA
Note: maximum open-circuit voltage is 28V
Maximum permitted line resistance
[(15 minus transmitter voltage requirement) x 50]
Input and output signal range
4 to 20mA with superimposed digital signal
Digital signal bandwidth (safe area to hazardous area)
10Hz to 8kHz
Digital signal bandwidth (hazardous area to safe area)
dc to 10kHz
Input resistance (terminals 6 & 8)
30
OTHER APPLICATIONS OF MTL3046B
Although designed for smart transmitter applications, the MTL3046B operates with standard analogue 4/20mA transmitters, and therefore can be especially useful if upgrading later to smart transmitters. The MTL3046B can be used to repeat a current generated by hazardous-area equipment in an existing barrier-protected safe-area circuit, to provide a fully isolated output with a high load handling capability. The MTL3046B operating with an MTL3045 can pass measurement and control signals through a hazardous area separating two safe areas (see MTL3045). The frequency response of dc to 10kHz (hazardous to safe area) makes the MTL3046B ideal for some flowmeter applications such as vortex and turbine meters.
MTL3992
MTL3099
MTL3081
MTL3073
MTL3072
MTL3071
MTL3058
MTL3059
MTL3054
MTL3052
MTL3046B
MTL3045
MTL3043
MTL3042
MTL3041
MTL3021
MTL3014
MTL3013
MTL3011
if you are intersted in more Allen-Bradley product, Please feel free to contct below contact me :windy@hkxytech.com
Windy Wang
HONGKONG XIEYUAN TECH CO., LIMITED
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com
Website: http://www.hkxytech.com/ | GMT/UTC +8