MTL
100% Original MTL3021 AND 3022 SOLENOID/ALARM DRIVERS In Ready Stock

100% Original MTL3021 AND 3022 SOLENOID/ALARM DRIVERS In Ready Stock

Model: MTL3021

$1.00

Supplier: Products

Categories: MTL

After sales service. If you have any questions, click here.

Product Description

100% Original MTL3021 AND 3022 SOLENOID/ALARM DRIVERS In Ready Stock


MTL3021 AND 3022,  loop powered.SOLENOID/ALARM DRIVERSMTL3021 – IIC, loop poweredMTL3022 – IIB, loop poweredThe MTL3021 enables a device in a hazardous area to be controlled by a switch or voltage 


The MTL3021 enables a device in a hazardous area to be controlled by a switch or voltage change in the safe area. It can drive any certified intrinsically safe, low-power load, for example a solenoid or alarm, as well as non-energy-storing ‘simple apparatus’ such as an LED. The unit’s input/output isolation allows field cables to be earthed and the control switch to be connected into either side of the 24V dc supply circuit. The MTL3022 is similar but provides more power for driving heavy-duty loads eg high-powered solenoid valves in areas where the explosion risk is limited to IIB atmospheres.


SPECIFICATION OF MTL3021

See also 'Common specification'

Number of channels

One, fully floating

Location of load

Zone 0, IIC, T4–6 hazardous area if suitably certified (3021)

Zone 0, IIB, T4–6 hazardous area if suitably certified (3022)

Div 1, Group A, hazardous location (3021)

Div 1, Group C, hazardous location (3022)

Input voltage

20 to 35V dc

Input current

20mA + (35V ÷ input voltage) x output current in mA

Maximum input current

130mA (MTL3021)

170mA (MTL3022)

Minimum output voltage


Maximum output voltage

28V from 300Ω, current limited at 65mA (MTL3021)

28V from 151Ω, current limited at 86mA (MTL3022)

Output ripple

<0.5% of maximum output, peak-to-peak

Response time

Settles to within 10% of final value after typically 10ms

Power requirement (MTL3021)

95mA typical at 24V

130mA maximum at 20 to 35V

Power requirement (MTL3022)

130mA typical at 24V

170mA maximum at 20 to 35V

Power dissipation within unit (MTL3021)

1.9W typical at 24V with 50mA output

2.1W maximum at 35V with 50mA output

Power dissipation within unit (MTL3022)

2.3W typical at 24V with 75mA output

2.5W maximum at 35V with 75mA outpu

Replaceable fuse

200mA, 5x20mm glass to DIN 41571 sht.2, semi-time-lag (M)

Safety description

28V, 300Ω, 93mA, Um = 250V rms or dc (MTL3021)

28V, 151Ω, 185mA, Um = 250V rms or dc (MTL3022)

FM max entity parameters

Voc = 28V, Isc = 93mA, Ca = 0.13µF, La = 4.0mH (MTL3021)

Voc = 28V, Isc = 185mA, Ca = 0.4µF, La = 4.0mH (MTL3022)

Weight

140g


100% Original MTL3021 AND 3022 SOLENOID/ALARM DRIVERS In Readt Stock


MTL3992

MTL3099

MTL3081

MTL3073

MTL3072

MTL3071

MTL3058

MTL3059

MTL3054

MTL3052

MTL3046B

MTL3045

MTL3043

MTL3042

MTL3041

MTL3021

MTL3014

MTL3013

MTL3011


PDE AND BRE


if you are intersted in more Allen-Bradley product, Please feel free to contct below contact me :windy@hkxytech.com 


Windy Wang 
HONGKONG XIEYUAN TECH CO., LIMITED  
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com 
Website:  http://www.hkxytech.com/   | GMT/UTC +8



Related Products