New Arrival MTL3013 SWITCH/ PROXIMITY DETECTORRELAY 2–channel In Good Price
MTL3013 SWITCH/ PROXIMITY DETECTORRELAY 2–channel.The MTL3013 has the same basic function as the MTL3011 but incorporates two channels in one unit. It enables two safe-area loadsto be controlled inde
The MTL3013 has the same basic function as the MTL3011 but incorporates two channels in one unit. It enables two safe-area loads to be controlled independently by proximity detectors or switches located in hazardous areas. The two input circuits are interconnected but fully floating, enabling two safe-area loads to be controlled by a single changeover switch if required. Each channel is provided with a phase reversal switch so that an alarm condition (output open) can be signalled for either state of the sensor. The status of each relay is indicated by an LED on top of the unit and an additional terminal block provides the four terminals needed for the connections from the two sets of relay contacts. If the application calls for line-fault detection, MTL3011 or MTL3014 units should be used instead.
SPECIFICATION OF MTL3013
See also 'Common specification'
Number of channels
Two, interconnected, fully floating
Location of switch
Zone 0, IIC, T6 hazardous area
Div 1, Group A, hazardous location
Location of proximity detector
Zone 0, IIC, T4–6 if suitably certified
Div 1, Group A, hazardous location
Voltage applied to sensor
7.0 to 8.5V dc from 970Ω
Input/output characteristics (each channel)
Output closed if >2.1mA* (<2kΩ) in sensor circuit
Output open if <1.2mA* (>10kΩ) in sensor circuit
Hysteresis: 200µA (650Ω) typical
*NAMUR and DIN19234 standards for proximity detectors
Phase reverse facility
Operations reversed by switches on top of unit
Power supply failure protection
Output circuits open if supply fails
Relay characteristics
Each single-pole on/off, open when relay de-energised
Response time: 10ms typical
Contact rating: 250V 5A 100VA (ac); 250V 5A 100W (dc)
Contact life expectancy: 1.5 x 105 operations at max. load,
>106 operations at 200V ac peak or dc, 10VA (resistive load)
Note: reactive loads must be adequately suppressed
LED indicators (each channel)
ON when output circuit is closed
Power requirement
55mA typical at 24V
75mA maximum at 20 to 35V
Power dissipation within unit
1.4W typical at 24V
1.6W maximum at 35V
Replaceable fuse
80mA, 5 x 20mm glass to DIN41571 sht 2, semi-time-lag (M)
Safety description (each channel)
10.5V, 800Ω, 14mA, Um = 250V rms or dc
FM max entity parameters
Voc = 10.5V, Isc = 14mA, Ca = 2.4µF, La = 165mH
Weight
170g
MTL3992
MTL3099
MTL3081
MTL3073
MTL3072
MTL3071
MTL3058
MTL3059
MTL3054
MTL3052
MTL3046B
MTL3045
MTL3043
MTL3042
MTL3041
MTL3021
MTL3014
MTL3013
MTL3011
if you are intersted in more Allen-Bradley product, Please feel free to contct below contact me :windy@hkxytech.com
Windy Wang
HONGKONG XIEYUAN TECH CO., LIMITED
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com
Website: http://www.hkxytech.com/ | GMT/UTC +8