MTL
100% Original MTL3011 AND 3012 SWITCH /PROXIMITY DETECTOR RELAYS In Good Price Ready To Ship

100% Original MTL3011 AND 3012 SWITCH /PROXIMITY DETECTOR RELAYS In Good Price Ready To Ship

Model: MTL3011

$1.00

Supplier: Products

Categories: MTL

After sales service. If you have any questions, click here.

Product Description

100% Original MTL3011 AND 3012 SWITCH /PROXIMITY DETECTOR RELAYS In Good Price Ready To Ship


MTL3011 AND 3012 SWITCH /PROXIMITY DETECTOR RELAYSMTL3011 – volt-free contacts MTL3012 – solid stateThese basically similar units both enable a safe-area load to be controlled by a proximity detecto


MTL3011 AND 3012 SWITCH /PROXIMITY DETECTOR RELAYS MTL3011 – volt-free contacts 

MTL3012 – solid state


These basically similar units both enable a safe-area load to be controlled by a proximity detector or switch located in a hazardous area, the MTL3011 having a relay output for general use, and the MTL3012 a floating solid-state on/off switch compatible with logic circuits. In both units a built-in phase-reverse control allows an alarm condition (output open) to be signalled for either state of the sensor. A line-fault detection feature opens the output in the event of short or open-circuit lines: intended for use primarily with proximity detectors, it can also be used with switches made to resemble them electrically by adding two resistors, or disabled by a link if not required.


SPECIFICATION OF MTL3011

See also 'Common specification'

Number of channels

One, fully floating

Location of switch

Zone 0, IIC, T6 hazardous area

Div 1, Group A, hazardous location

Location of proximity detector

Zone 0, IIC, T4–6 if suitably certified

Div 1, Group A, hazardous location

Voltage applied to sensor

7.7 to 9.0V dc from 1kΩ

Input/output characteristics

Output closed if >2.1mA* (<2kΩ) in sensor circuit

Output open if <1.2mA* (>10kΩ) in sensor circuit

Hysteresis: 200µA (650Ω) nominal

*NAMUR and DIN 19234 standards for proximity detectors

Phase reverse facility

Operation reversed by switch on top of unit

Power supply failure protection

Output circuit opens if supply fails

Broken/shorted lines protection

By built-in line-fault detection feature (LFD)

Output open if input current <100µA (broken line)

Output open if input current >6.5mA (shorted lines)

Note: to prevent false triggering of LFD, switch-type

sensors must be fitted with resistors as shown or LFD be

disabled by linking terminals 7 and 8

Output characteristics, MTL3011

Response time: 1ms typical

Contact rating: 200V, 0.5A, 10VA (ac); 200V, 0.5A, 10W (dc)

(USA: 60V) individual maxima, resistive loads

Contact life expectancy: 0.75 x 106 operations at max. load

Note: reactive loads must be adequately suppressed to protect the light-duty

contacts in this unit

Output characteristics, MTL3012

Operating frequency: typically dc to 2kHz

Maximum off-state voltage: 35V

Maximum off-state leakage current: 10µA

Maximum on-state voltage drop: 1+ (0.13 x current in mA) V

Maximum on-state current: 50mA

Note: the solid-state output is Zener-diode protected

against inductive loads

LED indicator

ON when output circuit is closed

Power requirement

25mA typical at 24V

35mA maximum at 20 to 35V

Power dissipation within unit

0.6W typical at 24V

1.3W maximum at 35V


Replaceable fuse

50mA, 5 x 20mm glass to DIN 41571 sht. 2, semi-time-lag (M)

Safety description

10.5V, 800Ω, 14mA, Um = 250V rms or dc

FM max entity parameters

Voc =10.5V, Isc =10.7mA, Ca = 3.0µF, La = 300mH

Weight

140g


MTL3011 AND 3012


MTL3992

MTL3099

MTL3081

MTL3073

MTL3072

MTL3071

MTL3058

MTL3059

MTL3054

MTL3052

MTL3046B

MTL3045

MTL3043

MTL3042

MTL3041

MTL3021

MTL3014

MTL3013

MTL3011


PDE AND BRE



Windy Wang 
HONGKONG XIEYUAN TECH CO., LIMITED  
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com 
Website:  http://www.hkxytech.com/   | GMT/UTC +8

Related Products