100% Original MTL3011 AND 3012 SWITCH /PROXIMITY DETECTOR RELAYS In Good Price Ready To Ship
MTL3011 AND 3012 SWITCH /PROXIMITY DETECTOR RELAYSMTL3011 – volt-free contacts MTL3012 – solid stateThese basically similar units both enable a safe-area load to be controlled by a proximity detecto
MTL3011 AND 3012 SWITCH /PROXIMITY DETECTOR RELAYS MTL3011 – volt-free contacts
MTL3012 – solid state
These basically similar units both enable a safe-area load to be controlled by a proximity detector or switch located in a hazardous area, the MTL3011 having a relay output for general use, and the MTL3012 a floating solid-state on/off switch compatible with logic circuits. In both units a built-in phase-reverse control allows an alarm condition (output open) to be signalled for either state of the sensor. A line-fault detection feature opens the output in the event of short or open-circuit lines: intended for use primarily with proximity detectors, it can also be used with switches made to resemble them electrically by adding two resistors, or disabled by a link if not required.
SPECIFICATION OF MTL3011
See also 'Common specification'
Number of channels
One, fully floating
Location of switch
Zone 0, IIC, T6 hazardous area
Div 1, Group A, hazardous location
Location of proximity detector
Zone 0, IIC, T4–6 if suitably certified
Div 1, Group A, hazardous location
Voltage applied to sensor
7.7 to 9.0V dc from 1kΩ
Input/output characteristics
Output closed if >2.1mA* (<2kΩ) in sensor circuit
Output open if <1.2mA* (>10kΩ) in sensor circuit
Hysteresis: 200µA (650Ω) nominal
*NAMUR and DIN 19234 standards for proximity detectors
Phase reverse facility
Operation reversed by switch on top of unit
Power supply failure protection
Output circuit opens if supply fails
Broken/shorted lines protection
By built-in line-fault detection feature (LFD)
Output open if input current <100µA (broken line)
Output open if input current >6.5mA (shorted lines)
Note: to prevent false triggering of LFD, switch-type
sensors must be fitted with resistors as shown or LFD be
disabled by linking terminals 7 and 8
Output characteristics, MTL3011
Response time: 1ms typical
Contact rating: 200V, 0.5A, 10VA (ac); 200V, 0.5A, 10W (dc)
(USA: 60V) individual maxima, resistive loads
Contact life expectancy: 0.75 x 106 operations at max. load
Note: reactive loads must be adequately suppressed to protect the light-duty
contacts in this unit
Output characteristics, MTL3012
Operating frequency: typically dc to 2kHz
Maximum off-state voltage: 35V
Maximum off-state leakage current: 10µA
Maximum on-state voltage drop: 1+ (0.13 x current in mA) V
Maximum on-state current: 50mA
Note: the solid-state output is Zener-diode protected
against inductive loads
LED indicator
ON when output circuit is closed
Power requirement
25mA typical at 24V
35mA maximum at 20 to 35V
Power dissipation within unit
0.6W typical at 24V
1.3W maximum at 35V
Replaceable fuse
50mA, 5 x 20mm glass to DIN 41571 sht. 2, semi-time-lag (M)
Safety description
10.5V, 800Ω, 14mA, Um = 250V rms or dc
FM max entity parameters
Voc =10.5V, Isc =10.7mA, Ca = 3.0µF, La = 300mH
Weight
140g
MTL3992
MTL3099
MTL3081
MTL3073
MTL3072
MTL3071
MTL3058
MTL3059
MTL3054
MTL3052
MTL3046B
MTL3045
MTL3043
MTL3042
MTL3041
MTL3021
MTL3014
MTL3013
MTL3011
Windy Wang
HONGKONG XIEYUAN TECH CO., LIMITED
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com
Website: http://www.hkxytech.com/ | GMT/UTC +8