MTL5000 Series
MTL5061 FIRE/SMOKE DETECTOR INTERFACE two-channel With Good Price In Ready Ship

MTL5061 FIRE/SMOKE DETECTOR INTERFACE two-channel With Good Price In Ready Ship

Model: MTL5061

$1.00

Supplier: MTL

Categories: MTL5000 Series

After sales service. If you have any questions, click here.

Product Description

MTL5061 FIRE/SMOKE DETECTOR INTERFACE two-channel With Good Price In Ready Ship


MTL5061 FIRE/SMOKE

DETECTOR INTERFACE two-channel, loop-powered


The MTL5061 is a loop-powered two-channel interface for use with conventional fire and smoke detectors located in hazardous areas. In

operation, the triggering of a detector causes a corresponding change in the safe-area circuit. The unit has reverse input polarity protection, while ‘non-fail’ earth fault detection on either line can be provided by connecting an earth leakage detector to terminals 3 or 6.


SPECIFICATION OF MTL5061

See also common specification

Number of channels

Two

Location of detectors

Zone 0, IIC, T4–6 hazardous area if suitably certified

Div. 1, Group A hazardous location

Current range

1 to 40mA, nominal

Integral input polarity protection

Input circuit protected against reverse polarity

‘No-fail‘ earth fault protection (optional)

Enabled by connecting terminals 3 and 6 to the MTL4220 earth

leakage detector. If a fault on either line of each channel is

proclaimed: unit continues working.

Note:1. The earth leakage detector introduces a 100µA, 1Hz ripple to the

field circuit.

Minimum output voltage Vout at 20ºC

whichever is the lower of:

Vin – (0.38 x current in mA) – 2V or

21V – (0.35 x current in mA)

Response time to step input

Settles to within 500µA of final value within 30ms

Hazardous-area output

Maximum output voltage 28V from 300Ω

Transfer accuracy at 20°C

Better than 400µA

Temperature drift

<10µA/°C (–20 to 60°C)


Loop supply voltage

6 to 35V dc

Quiescent safe-area current at 20°C

(hazardous-area terminals open-circuit)

<400µA/ channel, Vin = 24V dc

Maximum power dissipation within unit

0.7W at 24V with 40mA signal (each channel)

1.2W at 35V with 40mA signal (each channel)

Safety description

28V, 300Ω, 93mA; Um = 250V rms or dc



Approx weight:500G


Related Products: MTL5051 MTL5314 MTL5501-SR MTL5510 MTL5510B MTL5511 MTL5513 MTL5514 MTL5514-T MTL5514D MTL5516C MTL5517 MTL5521 MTL5521-T MTL5522 MTL5523 MTL5523V MTL5523VL MTL5524 MTL5525 MTL5526 MTL5531 MTL5532 MTL5532-R MTL5541 MTL5541-T MTL5541A MTL5541AS MTL5541S MTL5541S-T MTL5544 MTL5544A MTL5544AS MTL5544D MTL5544S MTL5546 MTL5546Y MTL5546Y-T MTL5549 MTL5549Y MTL5553 MTL5561 MTL5573 MTL5575 MTL5575-R MTL5576-RTD MTL5576-THC MTL5581 MTL5582 MTL5599 MTL5531 Pulse Isolator, with Current, Pluse, Voltage Inputs MTL 4525 MTL 4526 MTL 4531 MTL 4532 MTL 4533 MTL 4541 MTL 4541A MTL 4541AS MTL 4541B MTL 4541P MTL 4541S MTL 4541T MTL 4544 MTL 4544A MTL 4544AS MTL 4544B MTL 4544D MTL 4544S MTL 4546 MTL 4546C MTL 4546S MTL 4546Y MTL 4549 MTL 4549C MTL 4549Y MTL 4561 MTL 4575 MTL 4576-RTD MTL 4576-THC MTL 4581 MTL4599 MTL4599N 


MTL5061 FIRE/SMOKE DETECTOR INTERFACE two-channel With Good Price In Ready Ship


Windy Wang 

HONGKONG XIEYUAN TECH CO., LIMITED   

Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China 

Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | 

Skype: windy@hkxytech.com Mail: windy@hkxytech.com 

Website:  http://www.hkxytech.com/   | GMT/UTC +8




Related Products