MTL5000 Series
MTL5014 SWITCH/ PROXIMITY DETECTOR INTERFACE With Good Price In Ready Ship

MTL5014 SWITCH/ PROXIMITY DETECTOR INTERFACE With Good Price In Ready Ship

Model: MTL5014

$1.00

Supplier: MTL

Categories: MTL5000 Series

After sales service. If you have any questions, click here.

Product Description

MTL5014 SWITCH/ PROXIMITY DETECTOR INTERFACE With Good Price In Ready Ship


MTL5014 SWITCH/

PROXIMITY DETECTOR INTERFACE single-channel, dual-output, with phase reversal and line fault detection 



The MTL5014 enables two safe-area loads to be controlled by a single switch or proximity detector located in the hazardous area. The safearea interface has two changeover relays: output 1 and output 2. The output 1 relay reflects the status of the input and may be configured to operate in reverse phase. The output 2 relay may be configured either to repeat (slave) the output 1 relay, or to act as a line integrity monitor. A selectable line-fault-detect (LFD) facility enables an openor short- circuit fault to be detected in the field wiring.


SPECIFICATION OF MTL5014

See also common specification

Number of channels

One

Location of switches

Zone 0, IIC, T6 hazardous area

Div. 1, Group A hazardous location

Location of proximity detectors

Zone 0, IIC, T4–6 hazardous area if suitably certified

Div. 1, Group A hazardous location

Safe-area output

Two relays with changeover contacts

Hazardous-area input

One input conforming to NAMUR/DIN 19234 standards for

proximity detectors

Voltage applied to sensor

7.0 to 9.0V from 1kΩ ±10%

Input/output characteristics

Normal (reverse) phase:

 output energised (de-energised) if Iin >2.1mA or Rin <2kΩ

 output de-energised (energised) if Iin <1.2mA or Rin <10kΩ

Hysteresis: 250µA typical

Phase reversal

User selectable

Relay type

Single pole, changeover contacts

Note: reactive loads must be adequately suppressed

Relay characteristics

Response time: 10ms maximum

Contact rating: 250V ac, 2A, cosø >0.7

 40V dc, 2A, resistive load

Contact life expectancy: 3 x 105 operations at maximum load

Line fault detection (LFD)

User selectable: Off or On

A detected line fault de-energises Output 1 relay

Open circuit alarm on if Iin< 100µA

Short circuit alarm on if Iin > 6.5mA

Note: For contact input, resistors must be fitted

500Ω to 1kΩ in series with switch

20kΩ to 25kΩ in parallel with switch

Output 2 mode

User selectable: Slave or LFD mode

In LFD mode, a line fault de-energises Output 2 relay

Open circuit alarm on if Iin < 100µA

Short circuit alarm on if Iin > 6.5mA

See note above on use of resistors

In Slave mode output 2 repeats output 1

Power supply failure protection

Relays de-energised if supply fails


Related Products: MTL5051 MTL5314 MTL5501-SR MTL5510 MTL5510B MTL5511 MTL5513 MTL5514 MTL5514-T MTL5514D MTL5516C MTL5517 MTL5521 MTL5521-T MTL5522 MTL5523 MTL5523V MTL5523VL MTL5524 MTL5525 MTL5526 MTL5531 MTL5532 MTL5532-R MTL5541 MTL5541-T MTL5541A MTL5541AS MTL5541S MTL5541S-T MTL5544 MTL5544A MTL5544AS MTL5544D MTL5544S MTL5546 MTL5546Y MTL5546Y-T MTL5549 MTL5549Y MTL5553 MTL5561 MTL5573 MTL5575 MTL5575-R MTL5576-RTD MTL5576-THC MTL5581 MTL5582 MTL5599 MTL5531 Pulse Isolator, with Current, Pluse, Voltage Inputs MTL 4525 MTL 4526 MTL 4531 MTL 4532 MTL 4533 MTL 4541 MTL 4541A MTL 4541AS MTL 4541B MTL 4541P MTL 4541S MTL 4541T MTL 4544 MTL 4544A MTL 4544AS MTL 4544B MTL 4544D MTL 4544S MTL 4546 MTL 4546C MTL 4546S MTL 4546Y MTL 4549 MTL 4549C MTL 4549Y MTL 4561 MTL 4575 MTL 4576-RTD MTL 4576-THC MTL 4581 MTL4599 MTL4599N 


MTL5014 SWITCH/ PROXIMITY DETECTOR INTERFACE With Good Price In Ready Ship


Windy Wang 

HONGKONG XIEYUAN TECH CO., LIMITED   

Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China 

Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | 

Skype: windy@hkxytech.com Mail: windy@hkxytech.com 

Website:  http://www.hkxytech.com/   | GMT/UTC +8





Related Products