MTL5011B SWITCH/ PROXIMITY DETECTOR INTERFACE single-channel With Good Price In Ready Ship
MTL5011B SWITCH/ PROXIMITY DETECTOR INTERFACE single-channel, with line fault detection and phase reversal
The MTL5011B enables a safe-area load to be controlled by a switch or proximity detector located in a hazardous area. A relay output is provided. Phase reversal control allows an alarm condition to be signalled for either state of the sensor. A selectable line fault detect (LFD) facility detects an open or short circuit in the field circuit.
SPECIFICATION OF MTL5011B
See also common specification
Number of channels
One
Location of switch
Zone 0, IIC, T6 hazardous area
Div. 1, Group A hazardous location
Location of proximity detector
Zone 0, IIC, T4–6 hazardous area if suitably certified
Div. 1, Group A hazardous location
Safe-area output
One relay with changeover contacts
Hazardous-area input
Input conforming to NAMUR/DIN 19234 standards for proximity
detectors
Voltage applied to sensor
7 to 9V from 1kΩ ±10%
Input/output characteristics
Normal (reverse) phase:
output energised (de-energised) if Iin >2.1mA or Rin <2kΩ
output de-energised (energised) if Iin <1.2mA or Rin >10kΩ
Hysteresis: 200µA, typical
Line fault detection (LFD)
User-selectable, via switches on the top of unit. Line faults are
indicated by an LED. A detected line fault de-energises the relay.
Open-circuit alarm on if Iin<100µA
Open-circuit alarm off if Iin>250µA
Short-circuit alarm on if Rin<100Ω
Short-circuit alarm off if Rin>360Ω
Note: Resistors must be fitted when using the LFD facility with a contact input
500W to 1kW in series with switch
20kW to 25kW in parallel with switch
Phase reversal
User-selectable, via switches on the top of unit.
Relay type
Single-pole changeover relay
Note: reactive loads must be adequately suppressed
Relay characteristics
Response time: 10ms maximum
Contact rating: 250V ac, 2A, cosø >0.7
40V dc, 2A, resistive load
LED indicators
Green: power indication
Yellow: status of channel (on when outputs are energised)
Red: LFD indication (on when line fault detected)
Maximum current consumption
40mA at 20V
35mA at 24V
25mA at 35V
Maximum power dissipation
0.75W at 24V
0.8W at 35V
Isolation
250V ac or dc between power supply, hazardous-area circuits
and relay outputs
Safety description (each channel)
10.5V, 800Ω, 14mA, Um = 250V rms or dc
Related Products: MTL5051 MTL5314 MTL5501-SR MTL5510 MTL5510B MTL5511 MTL5513 MTL5514 MTL5514-T MTL5514D MTL5516C MTL5517 MTL5521 MTL5521-T MTL5522 MTL5523 MTL5523V MTL5523VL MTL5524 MTL5525 MTL5526 MTL5531 MTL5532 MTL5532-R MTL5541 MTL5541-T MTL5541A MTL5541AS MTL5541S MTL5541S-T MTL5544 MTL5544A MTL5544AS MTL5544D MTL5544S MTL5546 MTL5546Y MTL5546Y-T MTL5549 MTL5549Y MTL5553 MTL5561 MTL5573 MTL5575 MTL5575-R MTL5576-RTD MTL5576-THC MTL5581 MTL5582 MTL5599 MTL5531 Pulse Isolator, with Current, Pluse, Voltage Inputs MTL 4525 MTL 4526 MTL 4531 MTL 4532 MTL 4533 MTL 4541 MTL 4541A MTL 4541AS MTL 4541B MTL 4541P MTL 4541S MTL 4541T MTL 4544 MTL 4544A MTL 4544AS MTL 4544B MTL 4544D MTL 4544S MTL 4546 MTL 4546C MTL 4546S MTL 4546Y MTL 4549 MTL 4549C MTL 4549Y MTL 4561 MTL 4575 MTL 4576-RTD MTL 4576-THC MTL 4581 MTL4599 MTL4599N
Windy Wang
HONGKONG XIEYUAN TECH CO., LIMITED
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 |
Skype: windy@hkxytech.com Mail: windy@hkxytech.com
Website: http://www.hkxytech.com/ | GMT/UTC +8