MTL
100% Original New MTL2000 range MTL2213 3 channel Switch/proximity detector relay has been discontinued now In Ready Stock

100% Original New MTL2000 range MTL2213 3 channel Switch/proximity detector relay has been discontinued now In Ready Stock

Model: MTL2213

$1.00

Supplier: Products

Categories: MTL

After sales service. If you have any questions, click here.

Product Description

100% Original New MTL2000 range MTL2213 3 channel Switch/proximity detector relay has been discontinued now In Ready Stock


The MTL2213 enables three 100VA safe-area loads to be controlled independently by three light-duty on/off switches or certified proximity detectors in a hazardous area. Switches and proximity detectors may be mixed. The three input circuits are interconnected but fully floating. For proximity-detector and some switch applications, a phase-reverse link allows alarm conditions to be signalled for either state of the sensors. ‘Alarm’ means relays de-energised with their on/off contacts open, and all three circuits have to operate in the same fashion. This compact low-cost unit is suitable for a wide variety of applications. The MTL2213 supersedes the MTL2212 for which it is a direct replacement, except that only terminal 8 can be used for connecting to earth.


100% Original New MTL2000 range MTL2213 3 channel Switch/proximity detector relay has been discontinued now In Ready Stock


SPECIFICATION OF MTL2213

See also ‘Common specification’

Number of channels

Three, interconnected, fully floating

Location of switches

Zone 0, IIC, T6 hazardous area

Div 1, Group A, hazardous location

Location of proximity detectors

Zone 0, IIC, T4–T6 if suitably certified

Div 1, Group A, hazardous location

Voltage applied to each sensor

7.7 to 9.0V dc from 1kΩ

Input/output characteristics (each channel)

Relay energised if >2.1mA* (<2kΩ) in sensor circuit

Relay de-energised if <1.2mA* (>10kΩ) in sensor circuit

Hysteresis: 200μA (650Ω ) nominal

*NAMUR and DIN 19234 standards for proximity detectors

Phase reverse facility

Operation of all 3 relays reversed by linking terminals 7 & 8

Power supply failure protection

All three relays de-energised, contacts open, if supply fails

Broken line protection (each channel, normal phase only)

Relay de-energised, contacts open, if either line broken

Fail-safe earth fault protection (each channel, normal

phase only)

(Enabled by connecting terminal 8 to earth)

Relay de-energised if <25Ω to earth, total for both lines

Relay not de-energised if >52kΩto earth, total for both lines

‘No-fail’ earth fault protection (either phase)

(Enabled by connecting terminal 8 to MTL4220)

Fault on any line proclaimed: unit continues working

Response time (each channel)

50ms, nominal

Contacts (each channel)

On/off, open when relay de-energised

Contact rating

250V,5A,100VA (ac), resistive loads, reactive loads must be

suppressed

250V,5A,100W (dc), resistive loads, reactive loads must be

suppressed


MTL2220

MTL2215

MTL2213

MTL2211 

MTL2210B 

MTL2442B

MTL2441B

MTL2316

MTL2315

MTL2314 

MTL2313

MTL2242

MTL2241

MTL2220

MTL2215

MTL2213

MTL2211

MTL2210B


Windy Wang 
HONGKONG XIEYUAN TECH CO., LIMITED  
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com 
Website:  http://www.hkxytech.com/   | GMT/UTC +8