100% Original MTL2441B 4/20mA REPEATER POWER SUPPLY With Best Price In Ready Stock
The MTL2441B provides a floating dc supply for energising a 2- or 3- wire transmitter in a hazardous area and repeats the transmitter current in another floating circuit to drive a safe-area load. The unit can be used with all 2-wire transmitters certified as suitable for operation with safety barriers having a safety description of 28V, 300Ω. Other applications include repeating the current flowing in an existing barrier-protected loop to provide a fully isolated output with a high load handling capability and passing measurement or control signals (when used with an MTL2442B isolating driver) through a hazardous area separating two safe areas. The MTL2441B supersedes the MTL2441 but is designed for 240/120V ac supplies only. For a dc powered model choose the MTL5042 or MTL5045.
SPECIFICATION of MTL2441B
See also ‘Common specification’
Number of channels
One, fully floating
Location of transmitter
Zone 0, IIC, T4–T6 hazardous area if suitably certified
Div 1, Group A hazardous location if suitably certified
Voltage available for transmitter and lines
2-wire transmitter: 17.5V at 20mA (terminal 3 or 4 and 5)
3-wire transmitter: 18V at 20mA (terminal 3 or 4, and 6)
Note: maximum open-circuit voltage 28V
Maximum permitted line resistance
2-wire transmitter: 50 x (17.5V – transmitter voltage requirement) Ω
3-wire transmitter: dependent on transmitter characteristic
Input and output signal range
0 to 20mA
Input resistance (terminals 5 and 6)
≤32Ω (640mV at 20mA)
Safe-area circuit load resistance
1kΩ max
Safe area circuit output resistance
>1MΩ
Safe-area circuit ripple
<100µA peak-to-peak
Transfer accuracy at 20°C
Better than 20µA between 4 to 20mA
Temperature drift
<1µA/°C
Response time
Settles within 200µA of final value after 200ms
Power supply
240V ac nominal, 180–260V, 48–65Hz
120V ac nominal, 90–130V, 48–65Hz
Power consumption
5VA
Ambient temperature limits
–20 to +50°C close packed
–20 to +60°C at least 5mm apart
Safety description
Terminals 5 and 6 or 7
Non-energy storing allowing insertion into existing loops without
further certification
MTL2220
MTL2215
MTL2213
MTL2211
MTL2210B
MTL2442B
MTL2441B
MTL2316
MTL2315
MTL2314
MTL2313
MTL2242
MTL2241
MTL2220
MTL2215
MTL2213
MTL2211
MTL2210B