100% Original MTL2315 RTD TRIP AMPLIFIER With Bottom Price In Ready Stock
The MTL2315 energises a 3-wire 100Ω platinum resistance temperature detector in a hazardous area, and can be used with earthed or insulated sensors. Alternative versions are available to handle a single direct measurement, temperature difference between two similar sensors, or positional measurement made by a slidewire displacement transducer. Low power dissipation makes sure that selfheating errors in the sensor are neglible. Sensor failure (to open circuit) or any combination of broken leads de-energises the alarm relay(s). On-site alarm setting is made using a decade resistance box.
SPECIFICATION OF MTL2315
See also ‘Common specification’
Versions available
A: 1-alarm
B: 2-alarm
Signal source (factory-set)
Temperature: 3-wire platinum RTD to BS 1904, DIN 43760
(100Ω at 0°C)
Differential temperature: two RTD elements as above
Displacement: 3-wire 100Ω slidewire
Location of RTD or slidewire
Zone 0, IIC, T4 hazardous area
Div 1, Group A, hazardous location
Input range (factory-set)
–20 to +100°C
–50 to +250°C
–120 to +600°C
Displacement: 0 to 100Ω
Hysteresis: nominally 1% of input range
Power supply failure protection
Relay(s) de-energised if supply fails
Broken line protection
Relay(s) de-energised if any combination of leads goes open
circuit
Trip-point adjustment
Within 0.1% of input range over whole range (set by multi-turn
potentiometer accessible through casing)
Supply voltage effect on trip point
<0.1% of input range for supply voltage change within the
specified limits
Temperature effect on trip point
<0.015% of input range/°C
Input line resistance effect on trip point
<0.03% of setting/1Ω resistance in each line
500Ω maximum in each line
Response time
500ms, nominal
Alarm function (selectable)
High alarm: relay energised when input signal <trip point
Low alarm: relay energised when input signal >trip point
Alarm relay contacts
1-pole changeover (2-alarm version)
2-pole changeover (1-alarm version)
Contact rating
250V:5A:500VA (ac), resistive loads, reactive loads must be
suppressed
250V:5A:250W (dc), resistive loads, reactive loads must be
suppressed
Contact life expectancy
2-alarm versions: 3 x 105 operations at maximum load
1-alarm versions: 2 x 105 operations at maximum load
MTL2220
MTL2215
MTL2213
MTL2211
MTL2210B
MTL2442B
MTL2441B
MTL2316
MTL2315
MTL2314
MTL2313
MTL2242
MTL2241
MTL2220