100% Brand New MTL2210B SWITCH OPERATED RELAY 1-channel isolator With Good Price In Stock
The MTL2210B enables two 500VA safe-area loads to be controlled in separate circuits simultaneously by one light-duty on/off switch in a hazardous area. Alternatively, it can be arranged to latch for pushbutton stop/start control of an electric motor, the relay then being energised by brief closure of one switch contact and de-energised by the brief opening of another. The stop switch overrides the start switch, even if the start circuit is closed, making sure that the motor can be turned off under all conditions. In this application, the second pair of changeover output contacts enables the status of the motor to be fed to a computer or data logger.
SPECIFICATION OF MTL2210B
See also ‘Common specification’
Number of channels
One, fully floating
Location of switch(es)
Zone 0, IIC, T6 hazardous area
Div 1, Group A, hazardous location
Voltage applied to switch(es)
5.6V dc from 1.5kΩ
Input/output characteristics
Relay energised if <200Ω
between tmnls 1 & 2 and 3 & 4
Relay de-energised if >500Ω
between tmnls 1 & 2* or 3 & 4
Hysteresis, nominal 100Ω
*Non-latching mode
Latching facility
(Enabled by linking terminals 5 & 6)
Relay then latches ON when energised (shorts tmnls 1 & 2)
Relay de-energised if unlatch circuit broken (latching)
Power supply failure protection
Relay de-energised if supply fails
Broken line protection
Relay de-energised if either line broken (non-latching)
Relay de-energised if unlatch circuit broken (latching)
‘Fail-safe’ earth fault protection
(Enabled by connecting terminal 8 to earth) Relay de-energised if
<1kΩ to earth, total for all 3 lines Relay not de-energised if >7.5kΩ
to earth, total for all 3 lines
‘No-fail’ earth fault protection
(Enabled by connecting terminal 8 to MTL4220)
Fault on any line proclaimed: unit continues working
Response time
50ms, nominal
Contacts
2-pole changeover
Contact rating
250V:5A:500VA (ac) (resistive loads, reactive loads must be
suppressed)
250V:5A:250W (dc) (resistive loads, reactive loads must be
suppressed)
Contact life expectancy
2 x 105 operations at maximum load
LED indicator
ON when relay energised
MTL2220
MTL2215
MTL2213
MTL2211
MTL2210B
MTL2442B
MTL2441B
MTL2316
MTL2315
MTL2314
MTL2313
MTL2242
MTL2241
MTL2220
MTL2215
MTL2213
MTL2211
MTL2210B
Windy Wang
HONGKONG XIEYUAN TECH CO., LIMITED
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com
Website: http://www.hkxytech.com/ | GMT/UTC +8