Pepperl+Fuchs
Pepperl+Fuchs F2d0-Ti-Ex8.FF.Cgs.St P/N:125521 Temperature Multi-input Device With Aluminum Housting With Good Price In Stock

Pepperl+Fuchs F2d0-Ti-Ex8.FF.Cgs.St P/N:125521 Temperature Multi-input Device With Aluminum Housting With Good Price In Stock

Model: F2D0-TI-EX8.FF.CGS.ST

$1.00

Supplier: Products

Categories: Pepperl+Fuchs

After sales service. If you have any questions, click here.

Product Description

Pepperl+Fuchs F2D0-TI-EX8.FF.CGS.ST P/N:125521 Temperature Multi-input Device With Aluminum Housting With Good Price In Stock


  • For 8 temperature or analog sensors

  • Installation in Zone 1/Div. 1, intrinsically safe

  • Sensors in Zone 0/Div. 1

  • Connection to fieldbus acc. to FISCO or Entity

  • For FOUNDATION Fieldbus H1

  • PCS integration via device description and function blocks

  • Concentrator method for simplified configuration

  • Monitors sensor condition

  • For T/C, RTD 2-, 3-, 4-wire, voltage and resistance

  • Cold junction compensation

  • Removable terminals



Datasheet excerpt: Technical data of  F2D0-TI-Ex8.FF.*

General specifications
Design / MountingOutside installation
Electronic componentTemperature Multi-Input Device RD0-TI-Ex8.FF* For technical data on installed electronic component see data sheet.
Directive conformity
Electromagnetic compatibility

Directive 2014/30/EUEN 61326-1:2013
Standard conformity
Galvanic isolationEN 60079-11
Electromagnetic compatibilityNE 21:2011
Degree of protectionIEC 60529
Fieldbus standardIEC 61158-2
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
Ambient conditions
Ambient temperaturesee table 1
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity≤ 95 % non-condensing
Shock resistance15 g , 11 ms
Vibration resistance10 g , 10 ... 150 Hz
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3

F2D0-FB-Ex4.*

FieldBarrier®

4 outputs Ex ia IIC, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0...1/Div. 1, Short circuit current limitation per output, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Dust protection, International, Europe, USA, Canada, Device coupler location: Zone 2 - high-power trunk

Zone 1 - high-power trunk

Division 2 - high-power trunk, Device coupler location [2]: Zone 1 - high-power trunk, Device coupler location [3]: Division 2 - high-power trunk


F2D0-MIO-Ex12.FF.*

Multi-Input/Output Device with Aluminum Housing

For discrete inputs and outputs, Aluminum cast iron, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For FOUNDATION Fieldbus H1, IECEx approval, Dust protection, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area

Zone 2 - high-power trunk

Zone 1 - high-power trunk

Division 2 - high-power trunk

Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunk


F2D0-MIO-Ex12.PA.*

Multi-Input/Output Device with Aluminum Housing

For discrete inputs and outputs, Aluminum cast iron, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For PROFIBUS PA, IECEx approval, Dust protection, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area

Zone 2 - high-power trunk

Zone 1 - high-power trunk

Division 2 - high-power trunk

Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunk


F2D0-TI-Ex8.FF.*

Temperature Multi-Input Device with Aluminum Housing

For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1, IECEx approval, Dust protection, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area

Zone 2 - high-power trunk

Zone 1 - high-power trunk

Division 2 - high-power trunk

Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunk


F2D0-TI-Ex8.PA.*

Temperature Multi-Input Device with Aluminum Housing

For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA, IECEx approval, Dust protection, Europe, USA, Canada, Device coupler location: non-explosion hazardous area

Zone 2 - high-power trunk

Zone 1 - high-power trunk

Division 2 - high-power trunk

Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunk


ABOUT US


HONGKONG XIEYUAN TECH CO.,LTD, established in 7th Nov.,2012, a comprehensive corporation with its independent rights of export and import.. We are committed to providing customers with convenient and efficient industrial supplies services. From the product, price, logistics, service process for customers to improve procurement efficiency, reduce procurement costs, and grow together with customers.

 

Xieyuan sales of major brands are: Yokogawa, Siemens, ABB, Schneider, Emerson, Rosemount, Honeywell, Pepper+Fuchs, MTL, Fluke, Fisher, Endress+Hauser, Phoenix Contact, Weidmüller, Triconex, KROHNE, Dräger, Allen-Bradley, Omron, Eaton, SMC, Eaton, RAE, Testo, MSA, FESTO, Vega, Yaskawa, Danfoss, GE, Fisher, Hirschmann, IFM, Turck, MOXA, Foxboro etc.


Our wide range of products include Field Instruments, Field Communicator, Gas Detectors, Process Analyzers, Pressure Transmitters, Temperature Transmitters, Flow Meters, Inverters, Multimeters, Safety Barriers, Positioners, Controllers, Valves, Circuit Breakers, Sensors, DCS, PLC etc.


We endeavor to provide our customer with high quality, 100% original brand new products at competitive prices. Our targeting market includes Oil and Gas Industry, Refinery, Chemical, Mineral, Power and Energy, Ocean Engneering, Electricity, Food, Environment Protection and many other fields. 


We operate in more than 50 countries around the world. There are: Singapore, Indonesia, Malaysia, Philippines, Vietnam, Thailand, South Korea, Kazakhstan, Bangladesh, United Arab Emirates, Saudi Arabia, Iran, Iraq, Kuwait, Oman, Qatar,Germany, Italy, Austria, UK, Nigeria, Pakistan, Egypt, USA, Chile, Brazil, Mexico etc.



CHINA MAINLAND ADDRESS:

7-A16,CAISHEN COMMERCIAL PLAZA, HANKOU RAILWAY STATION, WUHAN, CHINA.


All products will send out within 72 hours, Please feel free to contact us! Thanks 


Windy Wang 
HONGKONG XIEYUAN TECH CO., LIMITED  
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com 
Website:  http://www.hkxytech.com/   | GMT/UTC +8


Related Products